The assessment of reinforced concrete solid floor slabs subjected to combined actions of vertical and lateral load

Reinforced concrete floor slabs carry gravity load and behave as rigid floor diaphragms to provide stability and lateral resistance to wind actions, earthquakes and lateral soil loads. Floor slabs are often analyzed and designed as uniform plate elements which only possess out-of plane stiffness to...

Full description

Saved in:
Bibliographic Details
Main Author: Ka Yik, Nin
Format: Thesis
Language:English
Published: 2012
Subjects:
Online Access:http://eprints.utm.my/id/eprint/10034/5/NinKaYikMFKA2012.pdf
http://eprints.utm.my/id/eprint/10034/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.10034
record_format eprints
spelling my.utm.100342018-05-27T03:19:43Z http://eprints.utm.my/id/eprint/10034/ The assessment of reinforced concrete solid floor slabs subjected to combined actions of vertical and lateral load Ka Yik, Nin T Technology (General) TA Engineering (General). Civil engineering (General) Reinforced concrete floor slabs carry gravity load and behave as rigid floor diaphragms to provide stability and lateral resistance to wind actions, earthquakes and lateral soil loads. Floor slabs are often analyzed and designed as uniform plate elements which only possess out-of plane stiffness to carry forces acting normal to the plane. However, an important issue which is often overlooked by the design engineers is that in order for a slab to provide ideal diaphragm actions, the slabs must possess adequate thickness. When slabs are subjected to out-of-plane bending moment due to gravity load and significant compressive forces, they would behave like a slender columns or walls. As consequences of additional deflection and secondary stresses on slabs, particularly at basement floor where lateral forces due to earth and water pressure are significant, the concrete slabs might crack. The project studied the assessment of strength and behaviour of conventional basement floor solid slabs that are subjected to combined actions of vertical and lateral forces. A typical conventional basement floor was proposed and analysed. The solid slabs panels were analysed and designed according to equation and coefficient in code of practice BS8110. Besides, first order and second order analysis using finite element method were carried on the proposed model subjected to gravity force and combined gravity and lateral forces. The results indicate that non-linear analysis could significantly increase the vertical deflection slabs upto 12.29%, bending moment upto 8.45% and shear forces upto 5.86% in minor or major axis of the slabs spanning. Possible visible cracking would occur near to the column support area and soffit of corner slab panels. 2012-01 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/10034/5/NinKaYikMFKA2012.pdf Ka Yik, Nin (2012) The assessment of reinforced concrete solid floor slabs subjected to combined actions of vertical and lateral load. Masters thesis, Universiti Teknologi Malaysia, Faculty of Civil Engineering.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic T Technology (General)
TA Engineering (General). Civil engineering (General)
spellingShingle T Technology (General)
TA Engineering (General). Civil engineering (General)
Ka Yik, Nin
The assessment of reinforced concrete solid floor slabs subjected to combined actions of vertical and lateral load
description Reinforced concrete floor slabs carry gravity load and behave as rigid floor diaphragms to provide stability and lateral resistance to wind actions, earthquakes and lateral soil loads. Floor slabs are often analyzed and designed as uniform plate elements which only possess out-of plane stiffness to carry forces acting normal to the plane. However, an important issue which is often overlooked by the design engineers is that in order for a slab to provide ideal diaphragm actions, the slabs must possess adequate thickness. When slabs are subjected to out-of-plane bending moment due to gravity load and significant compressive forces, they would behave like a slender columns or walls. As consequences of additional deflection and secondary stresses on slabs, particularly at basement floor where lateral forces due to earth and water pressure are significant, the concrete slabs might crack. The project studied the assessment of strength and behaviour of conventional basement floor solid slabs that are subjected to combined actions of vertical and lateral forces. A typical conventional basement floor was proposed and analysed. The solid slabs panels were analysed and designed according to equation and coefficient in code of practice BS8110. Besides, first order and second order analysis using finite element method were carried on the proposed model subjected to gravity force and combined gravity and lateral forces. The results indicate that non-linear analysis could significantly increase the vertical deflection slabs upto 12.29%, bending moment upto 8.45% and shear forces upto 5.86% in minor or major axis of the slabs spanning. Possible visible cracking would occur near to the column support area and soffit of corner slab panels.
format Thesis
author Ka Yik, Nin
author_facet Ka Yik, Nin
author_sort Ka Yik, Nin
title The assessment of reinforced concrete solid floor slabs subjected to combined actions of vertical and lateral load
title_short The assessment of reinforced concrete solid floor slabs subjected to combined actions of vertical and lateral load
title_full The assessment of reinforced concrete solid floor slabs subjected to combined actions of vertical and lateral load
title_fullStr The assessment of reinforced concrete solid floor slabs subjected to combined actions of vertical and lateral load
title_full_unstemmed The assessment of reinforced concrete solid floor slabs subjected to combined actions of vertical and lateral load
title_sort assessment of reinforced concrete solid floor slabs subjected to combined actions of vertical and lateral load
publishDate 2012
url http://eprints.utm.my/id/eprint/10034/5/NinKaYikMFKA2012.pdf
http://eprints.utm.my/id/eprint/10034/
_version_ 1643645308493627392
score 13.188404