CFD Analysis of the Effect of Heat Distribution on Different Heating Pad Piping Arrangements for Flexitank Application

Variations in piping arrangements of heating pad for flexitank applications causes a difference in the time required to completely liquidise the liquid during the discharging process. As reference, a conventional heating pad took about 48 hours to heat up the flexitank. There are many commercials h...

Full description

Saved in:
Bibliographic Details
Main Authors: Saiful Azam, Syafiqah Ruqaiyah, Darlis, Nofrizalidris, Mustaffa, Norrizal, Rahman Azahar, Mohamad Amirur, Sadun, Amirul Syafiq, Abu Hassan, Omar, Taib, Ishkrizat, Mustaffa, Khairul Nizam, Hashim, Muhamad Mohshein
Format: Article
Language:English
Published: semarak ilmu 2023
Subjects:
Online Access:http://eprints.uthm.edu.my/9768/1/J15717_b1bc05ca3c8df3e286c21e9f7811627a.pdf
http://eprints.uthm.edu.my/9768/
https://doi.org/10.37934/cfdl.15.2.115
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.9768
record_format eprints
spelling my.uthm.eprints.97682023-09-13T07:20:46Z http://eprints.uthm.edu.my/9768/ CFD Analysis of the Effect of Heat Distribution on Different Heating Pad Piping Arrangements for Flexitank Application Saiful Azam, Syafiqah Ruqaiyah Darlis, Nofrizalidris Mustaffa, Norrizal Rahman Azahar, Mohamad Amirur Sadun, Amirul Syafiq Abu Hassan, Omar Taib, Ishkrizat Mustaffa, Khairul Nizam Hashim, Muhamad Mohshein T Technology (General) Variations in piping arrangements of heating pad for flexitank applications causes a difference in the time required to completely liquidise the liquid during the discharging process. As reference, a conventional heating pad took about 48 hours to heat up the flexitank. There are many commercials heating pad used in flexitank applications to facilitate the discharging process of liquid. However, there are still uncertainty or limitation reference regarding the heating pad for flexitank application. One of the solutions to minimize the time taken for discharging processis identify the finest piping arrangement of heating pad. Based on the previous study, piping arrangement plays an important role for performance of the heating pad heat distribution. Thus, this paper aims to study the thermal behaviour of different heating pad arrangement for flexitank application with references to commercial arrangement of floor heating pad based on various inlet pressure using computational fluid dynamics (CFD) simulation software. This study was done by comparing thermal analysis of three piping arrangement which is conventional arrangement, Serpentine arrangement, and Spiral arrangement. The geometry of heating pad was created using Computer-Aided Design (CAD) software, SolidWorks. The results have discussed some important components parameter that must be controlled for the system to function efficiently. These parameters include pressure distribution within the pipes, temperature distribution along the pipes, and piping arrangement patterns. The simulation results show that the Counterflow arrangement has a uniform temperature distribution between the inlet and outlet. The study concluded that counterflow arrangement generally the best arrangement among these three since the configuration allowing less pressure losses and better thermal distribution on flexitank and heating pad. This study is therefore useful for designers to explore more adequately the benefits of underfloor heating system on many applications. semarak ilmu 2023 Article PeerReviewed text en http://eprints.uthm.edu.my/9768/1/J15717_b1bc05ca3c8df3e286c21e9f7811627a.pdf Saiful Azam, Syafiqah Ruqaiyah and Darlis, Nofrizalidris and Mustaffa, Norrizal and Rahman Azahar, Mohamad Amirur and Sadun, Amirul Syafiq and Abu Hassan, Omar and Taib, Ishkrizat and Mustaffa, Khairul Nizam and Hashim, Muhamad Mohshein (2023) CFD Analysis of the Effect of Heat Distribution on Different Heating Pad Piping Arrangements for Flexitank Application. CFD Letters, 15 (2). pp. 1-15. ISSN 2180-1363 https://doi.org/10.37934/cfdl.15.2.115
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
topic T Technology (General)
spellingShingle T Technology (General)
Saiful Azam, Syafiqah Ruqaiyah
Darlis, Nofrizalidris
Mustaffa, Norrizal
Rahman Azahar, Mohamad Amirur
Sadun, Amirul Syafiq
Abu Hassan, Omar
Taib, Ishkrizat
Mustaffa, Khairul Nizam
Hashim, Muhamad Mohshein
CFD Analysis of the Effect of Heat Distribution on Different Heating Pad Piping Arrangements for Flexitank Application
description Variations in piping arrangements of heating pad for flexitank applications causes a difference in the time required to completely liquidise the liquid during the discharging process. As reference, a conventional heating pad took about 48 hours to heat up the flexitank. There are many commercials heating pad used in flexitank applications to facilitate the discharging process of liquid. However, there are still uncertainty or limitation reference regarding the heating pad for flexitank application. One of the solutions to minimize the time taken for discharging processis identify the finest piping arrangement of heating pad. Based on the previous study, piping arrangement plays an important role for performance of the heating pad heat distribution. Thus, this paper aims to study the thermal behaviour of different heating pad arrangement for flexitank application with references to commercial arrangement of floor heating pad based on various inlet pressure using computational fluid dynamics (CFD) simulation software. This study was done by comparing thermal analysis of three piping arrangement which is conventional arrangement, Serpentine arrangement, and Spiral arrangement. The geometry of heating pad was created using Computer-Aided Design (CAD) software, SolidWorks. The results have discussed some important components parameter that must be controlled for the system to function efficiently. These parameters include pressure distribution within the pipes, temperature distribution along the pipes, and piping arrangement patterns. The simulation results show that the Counterflow arrangement has a uniform temperature distribution between the inlet and outlet. The study concluded that counterflow arrangement generally the best arrangement among these three since the configuration allowing less pressure losses and better thermal distribution on flexitank and heating pad. This study is therefore useful for designers to explore more adequately the benefits of underfloor heating system on many applications.
format Article
author Saiful Azam, Syafiqah Ruqaiyah
Darlis, Nofrizalidris
Mustaffa, Norrizal
Rahman Azahar, Mohamad Amirur
Sadun, Amirul Syafiq
Abu Hassan, Omar
Taib, Ishkrizat
Mustaffa, Khairul Nizam
Hashim, Muhamad Mohshein
author_facet Saiful Azam, Syafiqah Ruqaiyah
Darlis, Nofrizalidris
Mustaffa, Norrizal
Rahman Azahar, Mohamad Amirur
Sadun, Amirul Syafiq
Abu Hassan, Omar
Taib, Ishkrizat
Mustaffa, Khairul Nizam
Hashim, Muhamad Mohshein
author_sort Saiful Azam, Syafiqah Ruqaiyah
title CFD Analysis of the Effect of Heat Distribution on Different Heating Pad Piping Arrangements for Flexitank Application
title_short CFD Analysis of the Effect of Heat Distribution on Different Heating Pad Piping Arrangements for Flexitank Application
title_full CFD Analysis of the Effect of Heat Distribution on Different Heating Pad Piping Arrangements for Flexitank Application
title_fullStr CFD Analysis of the Effect of Heat Distribution on Different Heating Pad Piping Arrangements for Flexitank Application
title_full_unstemmed CFD Analysis of the Effect of Heat Distribution on Different Heating Pad Piping Arrangements for Flexitank Application
title_sort cfd analysis of the effect of heat distribution on different heating pad piping arrangements for flexitank application
publisher semarak ilmu
publishDate 2023
url http://eprints.uthm.edu.my/9768/1/J15717_b1bc05ca3c8df3e286c21e9f7811627a.pdf
http://eprints.uthm.edu.my/9768/
https://doi.org/10.37934/cfdl.15.2.115
_version_ 1778164192574963712
score 13.214268