Analysis of Switchgear on Insulation Performance and Reliability in Malaysian Railway Double Track Project

Switchgears are the key component in protecting equipment in High Voltage (HV) settings. With the rise of railway projects in Malaysia, there will be an increase in demand for switchgear for the electrification project. Therefore, the type of switchgear that is better in terms of insulation perform...

Full description

Saved in:
Bibliographic Details
Main Authors: Sahar, Norain, Ngadiron, Zuraidah, Zulkifli, Dinie Amani, Reventheran Ganasan, Reventheran Ganasan, Ismail, Noramin, N.A. Kamaluddin, N.A. Kamaluddin
Format: Article
Language:English
Published: IJETT 2023
Subjects:
Online Access:http://eprints.uthm.edu.my/9265/1/J16083_0e24af623f73dece81bba1031da0cfa1.pdf
http://eprints.uthm.edu.my/9265/
https://doi.org/10.14445/22315381/IJETT-V71I4P207
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.9265
record_format eprints
spelling my.uthm.eprints.92652023-07-17T07:46:47Z http://eprints.uthm.edu.my/9265/ Analysis of Switchgear on Insulation Performance and Reliability in Malaysian Railway Double Track Project Sahar, Norain Ngadiron, Zuraidah Zulkifli, Dinie Amani Reventheran Ganasan, Reventheran Ganasan Ismail, Noramin N.A. Kamaluddin, N.A. Kamaluddin T Technology (General) Switchgears are the key component in protecting equipment in High Voltage (HV) settings. With the rise of railway projects in Malaysia, there will be an increase in demand for switchgear for the electrification project. Therefore, the type of switchgear that is better in terms of insulation performance and reliability needs to be determined. Then, a simulation model is developed in order to measure the Partial Discharge (PD) in the insulation medium of the switchgears. An analysis is conducted in order to compare which insulation medium is superior for switchgear. It is found that Sulfur-Hexafluoride (SF6) gas is seen to have lower values of peak voltage during PD inside the insulation medium compared to air. SF6 gas proves to be the better insulation medium compared to air in terms of insulation performance and reliability due to the lower values of peak voltage detected during the occurrence of PD. The finding of insulation performances will enhance the quality of Malaysian railways in order to decrease the breakdowns and disturbances related to the electrification system IJETT 2023 Article PeerReviewed text en http://eprints.uthm.edu.my/9265/1/J16083_0e24af623f73dece81bba1031da0cfa1.pdf Sahar, Norain and Ngadiron, Zuraidah and Zulkifli, Dinie Amani and Reventheran Ganasan, Reventheran Ganasan and Ismail, Noramin and N.A. Kamaluddin, N.A. Kamaluddin (2023) Analysis of Switchgear on Insulation Performance and Reliability in Malaysian Railway Double Track Project. International Journal of Engineering Trends and Technology, 71 (4). pp. 72-78. ISSN 2231–5381 https://doi.org/10.14445/22315381/IJETT-V71I4P207
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
topic T Technology (General)
spellingShingle T Technology (General)
Sahar, Norain
Ngadiron, Zuraidah
Zulkifli, Dinie Amani
Reventheran Ganasan, Reventheran Ganasan
Ismail, Noramin
N.A. Kamaluddin, N.A. Kamaluddin
Analysis of Switchgear on Insulation Performance and Reliability in Malaysian Railway Double Track Project
description Switchgears are the key component in protecting equipment in High Voltage (HV) settings. With the rise of railway projects in Malaysia, there will be an increase in demand for switchgear for the electrification project. Therefore, the type of switchgear that is better in terms of insulation performance and reliability needs to be determined. Then, a simulation model is developed in order to measure the Partial Discharge (PD) in the insulation medium of the switchgears. An analysis is conducted in order to compare which insulation medium is superior for switchgear. It is found that Sulfur-Hexafluoride (SF6) gas is seen to have lower values of peak voltage during PD inside the insulation medium compared to air. SF6 gas proves to be the better insulation medium compared to air in terms of insulation performance and reliability due to the lower values of peak voltage detected during the occurrence of PD. The finding of insulation performances will enhance the quality of Malaysian railways in order to decrease the breakdowns and disturbances related to the electrification system
format Article
author Sahar, Norain
Ngadiron, Zuraidah
Zulkifli, Dinie Amani
Reventheran Ganasan, Reventheran Ganasan
Ismail, Noramin
N.A. Kamaluddin, N.A. Kamaluddin
author_facet Sahar, Norain
Ngadiron, Zuraidah
Zulkifli, Dinie Amani
Reventheran Ganasan, Reventheran Ganasan
Ismail, Noramin
N.A. Kamaluddin, N.A. Kamaluddin
author_sort Sahar, Norain
title Analysis of Switchgear on Insulation Performance and Reliability in Malaysian Railway Double Track Project
title_short Analysis of Switchgear on Insulation Performance and Reliability in Malaysian Railway Double Track Project
title_full Analysis of Switchgear on Insulation Performance and Reliability in Malaysian Railway Double Track Project
title_fullStr Analysis of Switchgear on Insulation Performance and Reliability in Malaysian Railway Double Track Project
title_full_unstemmed Analysis of Switchgear on Insulation Performance and Reliability in Malaysian Railway Double Track Project
title_sort analysis of switchgear on insulation performance and reliability in malaysian railway double track project
publisher IJETT
publishDate 2023
url http://eprints.uthm.edu.my/9265/1/J16083_0e24af623f73dece81bba1031da0cfa1.pdf
http://eprints.uthm.edu.my/9265/
https://doi.org/10.14445/22315381/IJETT-V71I4P207
_version_ 1772813821662986240
score 13.214268