Enantioselective analysis of ibuprofen, ketoprofen and naproxen in wastewater and environmental water samples

A highly sensitive and reliable method for the enantioselective analysis of ibuprofen, ketoprofen and naproxen in wastewater and environmental water samples has been developed. These three pharma�ceuticals are chiral molecules and the variable presence of their individual (R)- and (S)-enantiomers i...

Full description

Saved in:
Bibliographic Details
Main Authors: Hashim, Nor H., J. Khan, Stuart
Format: Article
Language:English
Published: Elsevier 2011
Subjects:
Online Access:http://eprints.uthm.edu.my/7990/1/J5716_2c99e89a5fcdc11672b9428e7b95b0c8.pdf
http://eprints.uthm.edu.my/7990/
https://doi.org/10.1016/j.chroma.2011.05.046
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.7990
record_format eprints
spelling my.uthm.eprints.79902022-11-08T01:37:46Z http://eprints.uthm.edu.my/7990/ Enantioselective analysis of ibuprofen, ketoprofen and naproxen in wastewater and environmental water samples Hashim, Nor H. J. Khan, Stuart T Technology (General) A highly sensitive and reliable method for the enantioselective analysis of ibuprofen, ketoprofen and naproxen in wastewater and environmental water samples has been developed. These three pharma�ceuticals are chiral molecules and the variable presence of their individual (R)- and (S)-enantiomers is of increasing interestfor environmental analysis. An indirect method for enantioseparation was achieved by the derivatization of the (R)- and (S)-enantiomers to amide diastereomers using (R)-1-phenylethylamine ((R)-1-PEA). After initial solid phase extraction from aqueous samples, derivatization was undertaken at room temperature in less than 5 min. Optimum recovery and clean-up of the amide diastereomers from the derivatization solution was achieved by a second solid phase extraction step. Separation and detec�tion ofthe individual diastereomers was undertaken by gas chromatography–tandem mass spectrometry (GC–MS/MS). Excellent analyte separation and peak shapes were achieved for the derivatized (R)- and (S)-enantiomers for all three pharmaceuticals with peak resolution, Rs is in the range of 2.87–4.02 for all diastereomer pairs. Furthermore, the calibration curves developed for the (S)-enantiomers revealed excellent linearity (r2 ≥ 0.99) for all three compounds. Method detection limits were shown to be within the range of 0.2–3.3 ng L−1 for individual enantiomers in ultrapure water, drinking water, surface water and a synthetic wastewater. Finally, the method was shown to perform well on a real tertiary treated wastewater sample, revealing measurable concentrations of both (R)- and (S)-enantiomers of ibupro�fen, naproxen and ketoprofen. Isotope dilution using racemic D3-ibuprofen, racemic D3-ketoprofen and racemic D3-naproxen was shown to be an essential aspect of this method for accurate quantification and enantiomeric fraction (EF) determination. This approach produced excellent reproducibility for EF determination of triplicate tertiary treated wastewater samples. Elsevier 2011 Article PeerReviewed text en http://eprints.uthm.edu.my/7990/1/J5716_2c99e89a5fcdc11672b9428e7b95b0c8.pdf Hashim, Nor H. and J. Khan, Stuart (2011) Enantioselective analysis of ibuprofen, ketoprofen and naproxen in wastewater and environmental water samples. Journal of Chromatography A, A (1218). pp. 4746-4754. https://doi.org/10.1016/j.chroma.2011.05.046
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
topic T Technology (General)
spellingShingle T Technology (General)
Hashim, Nor H.
J. Khan, Stuart
Enantioselective analysis of ibuprofen, ketoprofen and naproxen in wastewater and environmental water samples
description A highly sensitive and reliable method for the enantioselective analysis of ibuprofen, ketoprofen and naproxen in wastewater and environmental water samples has been developed. These three pharma�ceuticals are chiral molecules and the variable presence of their individual (R)- and (S)-enantiomers is of increasing interestfor environmental analysis. An indirect method for enantioseparation was achieved by the derivatization of the (R)- and (S)-enantiomers to amide diastereomers using (R)-1-phenylethylamine ((R)-1-PEA). After initial solid phase extraction from aqueous samples, derivatization was undertaken at room temperature in less than 5 min. Optimum recovery and clean-up of the amide diastereomers from the derivatization solution was achieved by a second solid phase extraction step. Separation and detec�tion ofthe individual diastereomers was undertaken by gas chromatography–tandem mass spectrometry (GC–MS/MS). Excellent analyte separation and peak shapes were achieved for the derivatized (R)- and (S)-enantiomers for all three pharmaceuticals with peak resolution, Rs is in the range of 2.87–4.02 for all diastereomer pairs. Furthermore, the calibration curves developed for the (S)-enantiomers revealed excellent linearity (r2 ≥ 0.99) for all three compounds. Method detection limits were shown to be within the range of 0.2–3.3 ng L−1 for individual enantiomers in ultrapure water, drinking water, surface water and a synthetic wastewater. Finally, the method was shown to perform well on a real tertiary treated wastewater sample, revealing measurable concentrations of both (R)- and (S)-enantiomers of ibupro�fen, naproxen and ketoprofen. Isotope dilution using racemic D3-ibuprofen, racemic D3-ketoprofen and racemic D3-naproxen was shown to be an essential aspect of this method for accurate quantification and enantiomeric fraction (EF) determination. This approach produced excellent reproducibility for EF determination of triplicate tertiary treated wastewater samples.
format Article
author Hashim, Nor H.
J. Khan, Stuart
author_facet Hashim, Nor H.
J. Khan, Stuart
author_sort Hashim, Nor H.
title Enantioselective analysis of ibuprofen, ketoprofen and naproxen in wastewater and environmental water samples
title_short Enantioselective analysis of ibuprofen, ketoprofen and naproxen in wastewater and environmental water samples
title_full Enantioselective analysis of ibuprofen, ketoprofen and naproxen in wastewater and environmental water samples
title_fullStr Enantioselective analysis of ibuprofen, ketoprofen and naproxen in wastewater and environmental water samples
title_full_unstemmed Enantioselective analysis of ibuprofen, ketoprofen and naproxen in wastewater and environmental water samples
title_sort enantioselective analysis of ibuprofen, ketoprofen and naproxen in wastewater and environmental water samples
publisher Elsevier
publishDate 2011
url http://eprints.uthm.edu.my/7990/1/J5716_2c99e89a5fcdc11672b9428e7b95b0c8.pdf
http://eprints.uthm.edu.my/7990/
https://doi.org/10.1016/j.chroma.2011.05.046
_version_ 1751538643184386048
score 13.160551