The blockage ratio effect to the spray performances

Nozzle sprays are used in wide range of application. The used of nozzle application is depend on the spray characteristics, by which to suit the particular application. This project studies the effect of the air blockage ratio to the spray characteristics. This research conducted into two part...

Full description

Saved in:
Bibliographic Details
Main Authors: Pairan, Mohamad Rasidi, Osman, Sharul Azmir, Md Nasir, , Ahmad Nabil, Noh@Seth, Nur Hazirah, Mohd Hisham, Mohd Hizwan, Mazlan, Adjah Naqkiah, Jambari, Hanifah, Aripin, Muhamad Afzamiman
Format: Article
Language:English
Published: Semarak Ilmu 2022
Subjects:
Online Access:http://eprints.uthm.edu.my/7613/1/J14531_7329b1117ffc476988959fa11b04325c.pdf
http://eprints.uthm.edu.my/7613/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.7613
record_format eprints
spelling my.uthm.eprints.76132022-09-08T02:08:51Z http://eprints.uthm.edu.my/7613/ The blockage ratio effect to the spray performances Pairan, Mohamad Rasidi Osman, Sharul Azmir Md Nasir, , Ahmad Nabil Noh@Seth, Nur Hazirah Mohd Hisham, Mohd Hizwan Mazlan, Adjah Naqkiah Jambari, Hanifah Aripin, Muhamad Afzamiman T Technology (General) Nozzle sprays are used in wide range of application. The used of nozzle application is depend on the spray characteristics, by which to suit the particular application. This project studies the effect of the air blockage ratio to the spray characteristics. This research conducted into two part which are experimental and simulation section. The experimental was conducted by using particle image velocimetry (PIV) method, and ANSYS software was used as tools for simulation section. There are two nozzles were tested at 1 bar pressure of water and air. Nozzle A (with blockage ratio 0.316) and nozzle B (blockage ratio 1.000). Both of the sprays performances generated by the nozzles was examined at 9 cm vertical line from 8 cm of the nozzle orifice. The validation result provided in the detailed analysis shows that the trend of graph velocity versus distance gives the good agreement within simulation and experiment. From result, nozzle A generated a wider spray angle and higher water droplet velocity which are 31.41 degree and 37.317 m/s compared to nozzle B which has produced 27.13 degree of spray penetration angle and 16.49 m/s water droplet velocity. As a conclusion, blockage ratio has affected the spray system by increasing the velocity of air inside the spray system. This is happened at a condition of 1 bar air pressure. Semarak Ilmu 2022 Article PeerReviewed text en http://eprints.uthm.edu.my/7613/1/J14531_7329b1117ffc476988959fa11b04325c.pdf Pairan, Mohamad Rasidi and Osman, Sharul Azmir and Md Nasir, , Ahmad Nabil and Noh@Seth, Nur Hazirah and Mohd Hisham, Mohd Hizwan and Mazlan, Adjah Naqkiah and Jambari, Hanifah and Aripin, Muhamad Afzamiman (2022) The blockage ratio effect to the spray performances. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 95 (1). pp. 99-109.
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
topic T Technology (General)
spellingShingle T Technology (General)
Pairan, Mohamad Rasidi
Osman, Sharul Azmir
Md Nasir, , Ahmad Nabil
Noh@Seth, Nur Hazirah
Mohd Hisham, Mohd Hizwan
Mazlan, Adjah Naqkiah
Jambari, Hanifah
Aripin, Muhamad Afzamiman
The blockage ratio effect to the spray performances
description Nozzle sprays are used in wide range of application. The used of nozzle application is depend on the spray characteristics, by which to suit the particular application. This project studies the effect of the air blockage ratio to the spray characteristics. This research conducted into two part which are experimental and simulation section. The experimental was conducted by using particle image velocimetry (PIV) method, and ANSYS software was used as tools for simulation section. There are two nozzles were tested at 1 bar pressure of water and air. Nozzle A (with blockage ratio 0.316) and nozzle B (blockage ratio 1.000). Both of the sprays performances generated by the nozzles was examined at 9 cm vertical line from 8 cm of the nozzle orifice. The validation result provided in the detailed analysis shows that the trend of graph velocity versus distance gives the good agreement within simulation and experiment. From result, nozzle A generated a wider spray angle and higher water droplet velocity which are 31.41 degree and 37.317 m/s compared to nozzle B which has produced 27.13 degree of spray penetration angle and 16.49 m/s water droplet velocity. As a conclusion, blockage ratio has affected the spray system by increasing the velocity of air inside the spray system. This is happened at a condition of 1 bar air pressure.
format Article
author Pairan, Mohamad Rasidi
Osman, Sharul Azmir
Md Nasir, , Ahmad Nabil
Noh@Seth, Nur Hazirah
Mohd Hisham, Mohd Hizwan
Mazlan, Adjah Naqkiah
Jambari, Hanifah
Aripin, Muhamad Afzamiman
author_facet Pairan, Mohamad Rasidi
Osman, Sharul Azmir
Md Nasir, , Ahmad Nabil
Noh@Seth, Nur Hazirah
Mohd Hisham, Mohd Hizwan
Mazlan, Adjah Naqkiah
Jambari, Hanifah
Aripin, Muhamad Afzamiman
author_sort Pairan, Mohamad Rasidi
title The blockage ratio effect to the spray performances
title_short The blockage ratio effect to the spray performances
title_full The blockage ratio effect to the spray performances
title_fullStr The blockage ratio effect to the spray performances
title_full_unstemmed The blockage ratio effect to the spray performances
title_sort blockage ratio effect to the spray performances
publisher Semarak Ilmu
publishDate 2022
url http://eprints.uthm.edu.my/7613/1/J14531_7329b1117ffc476988959fa11b04325c.pdf
http://eprints.uthm.edu.my/7613/
_version_ 1744355838993104896
score 13.160551