Building energy index (BEI) of hospital buildings in Iraq: A case study

Hospitals are generally made by a large complex with many buildings serving different functions. These buildings such as the patient registration area, wards, operation theatre, emergency and trauma department and pharmacy operate continuously for twenty-four hours daily throughout the year, hen...

Full description

Saved in:
Bibliographic Details
Main Authors: Gatea, Anwer Abdulhussein, Batcha, Mohd Faizal Mohideen
Format: Article
Language:English
Published: Prince of Songkla University 2021
Subjects:
Online Access:http://eprints.uthm.edu.my/7604/1/J14457_5bcc14128188d2da90ef2dada157d7aa.pdf
http://eprints.uthm.edu.my/7604/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.7604
record_format eprints
spelling my.uthm.eprints.76042022-08-29T07:37:02Z http://eprints.uthm.edu.my/7604/ Building energy index (BEI) of hospital buildings in Iraq: A case study Gatea, Anwer Abdulhussein Batcha, Mohd Faizal Mohideen T Technology (General) Hospitals are generally made by a large complex with many buildings serving different functions. These buildings such as the patient registration area, wards, operation theatre, emergency and trauma department and pharmacy operate continuously for twenty-four hours daily throughout the year, hence consuming a large amount of energy. This paper presents a pioneering case study carried out at three hospitals in Iraq, designated as Hospital A, Hospital B and Hospital C to analyze their energy intensity by determining the building energy index (BEI). This study also identified the factors affecting energy usage in these hospitals. Detailed energy audits were carried out in these hospitals, followed by desktop analysis and comparison with BEI values from selected hospitals reported in the literature. It was found that the average electricity consumed annually for a period of three years (2016 to 2018) by Hospital A, B, and C were 19,280,900 kWh, 11,958,121 kWh and 4,275,760 kWh, respectively. It was also found that more than 60% of the energy consumed in all three hospitals were by the air conditioning systems hence becoming the significant energy user (SEU). The study thus proposes methods to reduce the energy consumption in these hospitals without reducing their level of comfort. It was also found that the outside ambient temperature was the main factor that affecting the energy consumption in the building. The study concludes that the BEI values attained for the hospitals in this case study ranged from 360 to 532 kWh/m2 /year, which are relatively high and hence signifies the energy efficiency measures to be implemented in these hospitals. Prince of Songkla University 2021 Article PeerReviewed text en http://eprints.uthm.edu.my/7604/1/J14457_5bcc14128188d2da90ef2dada157d7aa.pdf Gatea, Anwer Abdulhussein and Batcha, Mohd Faizal Mohideen (2021) Building energy index (BEI) of hospital buildings in Iraq: A case study. Songklanakarin J. Sci. Technol., 43 (6). pp. 1779-1785.
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
topic T Technology (General)
spellingShingle T Technology (General)
Gatea, Anwer Abdulhussein
Batcha, Mohd Faizal Mohideen
Building energy index (BEI) of hospital buildings in Iraq: A case study
description Hospitals are generally made by a large complex with many buildings serving different functions. These buildings such as the patient registration area, wards, operation theatre, emergency and trauma department and pharmacy operate continuously for twenty-four hours daily throughout the year, hence consuming a large amount of energy. This paper presents a pioneering case study carried out at three hospitals in Iraq, designated as Hospital A, Hospital B and Hospital C to analyze their energy intensity by determining the building energy index (BEI). This study also identified the factors affecting energy usage in these hospitals. Detailed energy audits were carried out in these hospitals, followed by desktop analysis and comparison with BEI values from selected hospitals reported in the literature. It was found that the average electricity consumed annually for a period of three years (2016 to 2018) by Hospital A, B, and C were 19,280,900 kWh, 11,958,121 kWh and 4,275,760 kWh, respectively. It was also found that more than 60% of the energy consumed in all three hospitals were by the air conditioning systems hence becoming the significant energy user (SEU). The study thus proposes methods to reduce the energy consumption in these hospitals without reducing their level of comfort. It was also found that the outside ambient temperature was the main factor that affecting the energy consumption in the building. The study concludes that the BEI values attained for the hospitals in this case study ranged from 360 to 532 kWh/m2 /year, which are relatively high and hence signifies the energy efficiency measures to be implemented in these hospitals.
format Article
author Gatea, Anwer Abdulhussein
Batcha, Mohd Faizal Mohideen
author_facet Gatea, Anwer Abdulhussein
Batcha, Mohd Faizal Mohideen
author_sort Gatea, Anwer Abdulhussein
title Building energy index (BEI) of hospital buildings in Iraq: A case study
title_short Building energy index (BEI) of hospital buildings in Iraq: A case study
title_full Building energy index (BEI) of hospital buildings in Iraq: A case study
title_fullStr Building energy index (BEI) of hospital buildings in Iraq: A case study
title_full_unstemmed Building energy index (BEI) of hospital buildings in Iraq: A case study
title_sort building energy index (bei) of hospital buildings in iraq: a case study
publisher Prince of Songkla University
publishDate 2021
url http://eprints.uthm.edu.my/7604/1/J14457_5bcc14128188d2da90ef2dada157d7aa.pdf
http://eprints.uthm.edu.my/7604/
_version_ 1743109106473893888
score 13.214268