PLC design for automatic power transfer of 11kv switchgear

An Automated Transfer System (ATS) is to provide automatic power transfers to groups reloading loads from common sources, such as utility services, to alternative sources, such as standby generation, in the event of a normal source failure. The project aims to develop a new design of an auto...

Full description

Saved in:
Bibliographic Details
Main Authors: Wahid, Herman, Omar, Azmi, Ismail, Mohd Fauzi, Ahmad, Nasarudin, Sahlan, Shafishuhaza, Mohamad, Elmy Johana, Abdul Wahab, Yasmin
Other Authors: Shamsudin, Abu Ubaidah
Format: Book Section
Language:English
Published: Penerbit UTHM 2022
Subjects:
Online Access:http://eprints.uthm.edu.my/7433/1/2.pdf
http://eprints.uthm.edu.my/7433/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.7433
record_format eprints
spelling my.uthm.eprints.74332022-07-21T07:23:01Z http://eprints.uthm.edu.my/7433/ PLC design for automatic power transfer of 11kv switchgear Wahid, Herman Omar, Azmi Ismail, Mohd Fauzi Ahmad, Nasarudin Sahlan, Shafishuhaza Mohamad, Elmy Johana Abdul Wahab, Yasmin T Technology (General) An Automated Transfer System (ATS) is to provide automatic power transfers to groups reloading loads from common sources, such as utility services, to alternative sources, such as standby generation, in the event of a normal source failure. The project aims to develop a new design of an automatic power transfer system for the 11kV switchgear. Using the basic building blocks of utility power, system topology, on-site generation, and uninterrupted power supply, the basic role of the automatic transfer system can now be determined. In this role, the Automatic Transfer System (ATS) must achieve two goals. First, the system must be stable where it should operate, even under abnormal power systems, without human intervention. Equally important, it must be able to distinguish when the system conditions do not guarantee transfer to alternate sources. Second, it must be able to control the switchgear as required and, in addition, be able to deliver accurate signal to the required alternative power sources (for example, to initiate start signal to the generator as soon as possible). Penerbit UTHM Shamsudin, Abu Ubaidah Ahmad, Anita Abdul Rahim, Ruzairi 2022 Book Section PeerReviewed text en http://eprints.uthm.edu.my/7433/1/2.pdf Wahid, Herman and Omar, Azmi and Ismail, Mohd Fauzi and Ahmad, Nasarudin and Sahlan, Shafishuhaza and Mohamad, Elmy Johana and Abdul Wahab, Yasmin (2022) PLC design for automatic power transfer of 11kv switchgear. In: Sensor & Instrumentation System. Penerbit UTHM, UTHM, pp. 23-40. ISBN 978-967-2817-62-8
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
topic T Technology (General)
spellingShingle T Technology (General)
Wahid, Herman
Omar, Azmi
Ismail, Mohd Fauzi
Ahmad, Nasarudin
Sahlan, Shafishuhaza
Mohamad, Elmy Johana
Abdul Wahab, Yasmin
PLC design for automatic power transfer of 11kv switchgear
description An Automated Transfer System (ATS) is to provide automatic power transfers to groups reloading loads from common sources, such as utility services, to alternative sources, such as standby generation, in the event of a normal source failure. The project aims to develop a new design of an automatic power transfer system for the 11kV switchgear. Using the basic building blocks of utility power, system topology, on-site generation, and uninterrupted power supply, the basic role of the automatic transfer system can now be determined. In this role, the Automatic Transfer System (ATS) must achieve two goals. First, the system must be stable where it should operate, even under abnormal power systems, without human intervention. Equally important, it must be able to distinguish when the system conditions do not guarantee transfer to alternate sources. Second, it must be able to control the switchgear as required and, in addition, be able to deliver accurate signal to the required alternative power sources (for example, to initiate start signal to the generator as soon as possible).
author2 Shamsudin, Abu Ubaidah
author_facet Shamsudin, Abu Ubaidah
Wahid, Herman
Omar, Azmi
Ismail, Mohd Fauzi
Ahmad, Nasarudin
Sahlan, Shafishuhaza
Mohamad, Elmy Johana
Abdul Wahab, Yasmin
format Book Section
author Wahid, Herman
Omar, Azmi
Ismail, Mohd Fauzi
Ahmad, Nasarudin
Sahlan, Shafishuhaza
Mohamad, Elmy Johana
Abdul Wahab, Yasmin
author_sort Wahid, Herman
title PLC design for automatic power transfer of 11kv switchgear
title_short PLC design for automatic power transfer of 11kv switchgear
title_full PLC design for automatic power transfer of 11kv switchgear
title_fullStr PLC design for automatic power transfer of 11kv switchgear
title_full_unstemmed PLC design for automatic power transfer of 11kv switchgear
title_sort plc design for automatic power transfer of 11kv switchgear
publisher Penerbit UTHM
publishDate 2022
url http://eprints.uthm.edu.my/7433/1/2.pdf
http://eprints.uthm.edu.my/7433/
_version_ 1739830458379665408
score 13.214268