Three phase synchronous motor has a wide range of applications. Its constant�speed operation (even under load variation and voltage fluctuation) and high efficiency make it most suitable for constant-speed, continuous-running drives such as motor�generator sets, air compressors, centrifugal pumps,...

Full description

Saved in:
Bibliographic Details
Main Author: Jenal, Mahyuzie
Format: Thesis
Language:English
English
English
Published: 2009
Subjects:
Online Access:http://eprints.uthm.edu.my/7339/1/24p%20MAHYUZIE%20JENAL.pdf
http://eprints.uthm.edu.my/7339/2/MAHYUZIE%20JENAL%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/7339/3/MAHYUZIE%20JENAL%20WATERMARK.pdf
http://eprints.uthm.edu.my/7339/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.7339
record_format eprints
spelling my.uthm.eprints.73392022-07-21T04:06:36Z http://eprints.uthm.edu.my/7339/ Performance characteristics of inverter driven synchronous motor Jenal, Mahyuzie TK Electrical engineering. Electronics Nuclear engineering TK2000-2891 Dynamoelectric machinery and auxiliaries. Including generators, motors, transformers Three phase synchronous motor has a wide range of applications. Its constant�speed operation (even under load variation and voltage fluctuation) and high efficiency make it most suitable for constant-speed, continuous-running drives such as motor�generator sets, air compressors, centrifugal pumps, blowers, crushers and many types of continuous-processing mills. However, this motor is not a self-started type. There are many methods implemented in order to bring up the motor's speed to the required limit. One of the approaches is by using variable-frequency supply starter that is used in this project work. Realizing the importance of motor performance information in practice, this project aimed to carry out the standard motor tests and observe the characteristics. Two main methods are applied in this particular system where one of them is by running up the synchronous motor conventionally. "Prime mover" is coupled to the motor and drives it to the desired speed before supplying electrical sources. The other method is by using variable-frequency (inverter) supply connected to the synchronous motor and run the motor accordingly. A number of experiments are set up either with and without the inverter to analyze and compare their performance characteristics. The results are reported and discussed in this work. 2009-05 Thesis NonPeerReviewed text en http://eprints.uthm.edu.my/7339/1/24p%20MAHYUZIE%20JENAL.pdf text en http://eprints.uthm.edu.my/7339/2/MAHYUZIE%20JENAL%20COPYRIGHT%20DECLARATION.pdf text en http://eprints.uthm.edu.my/7339/3/MAHYUZIE%20JENAL%20WATERMARK.pdf Jenal, Mahyuzie (2009) Performance characteristics of inverter driven synchronous motor. Masters thesis, Universiti Tun Hussein Onn Malaysia.
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
English
English
topic TK Electrical engineering. Electronics Nuclear engineering
TK2000-2891 Dynamoelectric machinery and auxiliaries. Including generators, motors, transformers
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
TK2000-2891 Dynamoelectric machinery and auxiliaries. Including generators, motors, transformers
Jenal, Mahyuzie
Performance characteristics of inverter driven synchronous motor
description Three phase synchronous motor has a wide range of applications. Its constant�speed operation (even under load variation and voltage fluctuation) and high efficiency make it most suitable for constant-speed, continuous-running drives such as motor�generator sets, air compressors, centrifugal pumps, blowers, crushers and many types of continuous-processing mills. However, this motor is not a self-started type. There are many methods implemented in order to bring up the motor's speed to the required limit. One of the approaches is by using variable-frequency supply starter that is used in this project work. Realizing the importance of motor performance information in practice, this project aimed to carry out the standard motor tests and observe the characteristics. Two main methods are applied in this particular system where one of them is by running up the synchronous motor conventionally. "Prime mover" is coupled to the motor and drives it to the desired speed before supplying electrical sources. The other method is by using variable-frequency (inverter) supply connected to the synchronous motor and run the motor accordingly. A number of experiments are set up either with and without the inverter to analyze and compare their performance characteristics. The results are reported and discussed in this work.
format Thesis
author Jenal, Mahyuzie
author_facet Jenal, Mahyuzie
author_sort Jenal, Mahyuzie
title Performance characteristics of inverter driven synchronous motor
title_short Performance characteristics of inverter driven synchronous motor
title_full Performance characteristics of inverter driven synchronous motor
title_fullStr Performance characteristics of inverter driven synchronous motor
title_full_unstemmed Performance characteristics of inverter driven synchronous motor
title_sort performance characteristics of inverter driven synchronous motor
publishDate 2009
url http://eprints.uthm.edu.my/7339/1/24p%20MAHYUZIE%20JENAL.pdf
http://eprints.uthm.edu.my/7339/2/MAHYUZIE%20JENAL%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/7339/3/MAHYUZIE%20JENAL%20WATERMARK.pdf
http://eprints.uthm.edu.my/7339/
_version_ 1739830444624445440
score 13.160551