Alarm design for SCADA system of assembly CELL-200 trainer

Alarm systems play a vital role in maintaining the safe operation in process plant. Moreover, the safety and efficiency of a plant's operation is assured by the usage of a reliable and user friendly alarm system. In this project, the main objective is to introduce an alarm feature inside the...

Full description

Saved in:
Bibliographic Details
Main Author: Zawawi, Mukmin
Format: Thesis
Language:English
English
English
Published: 2008
Subjects:
Online Access:http://eprints.uthm.edu.my/7084/1/24p%20MUKMIN%20ZAWAWI.pdf
http://eprints.uthm.edu.my/7084/2/MUKMIN%20ZAWAWI%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/7084/3/MUKMIN%20ZAWAWI%20WATERMARK.pdf
http://eprints.uthm.edu.my/7084/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.7084
record_format eprints
spelling my.uthm.eprints.70842022-05-30T00:40:39Z http://eprints.uthm.edu.my/7084/ Alarm design for SCADA system of assembly CELL-200 trainer Zawawi, Mukmin TJ Mechanical engineering and machinery TJ212-225 Control engineering systems. Automatic machinery (General) Alarm systems play a vital role in maintaining the safe operation in process plant. Moreover, the safety and efficiency of a plant's operation is assured by the usage of a reliable and user friendly alarm system. In this project, the main objective is to introduce an alarm feature inside the SCADA system. Identification of suitable guidelines in designing a good alarm system display is also part of the project's objective. Introduction of alarm feature inside the SCADA system is done by putting the Supervisory Control and Data Acquisition (SCADA) system to Assembly Cell-200 Trainer. Here, the SCADA system is equipped with an alarm system as the mean to monitor and control the trainer. The alarm design adopts the available alarm system guidelines as to figure out and judge the most suitable guidelines to be applied in this project. This exercise proves that general guidelines (e.g., use of an alarm philosophy) are essential in developing this projects. However, detailed guidelines (e.g., colour coding and symbol features) should be used more carefully and consistent to ensure the creation of understandable and recognizable display. From this project, a properly designed alarm system is developed, which provides the operators with enough information to prevent any abnormalities, fault conditions or undesired errors in the plant. This project also summarizes the principal guidelines to consider when designing and developing alarms in SCADA environment. 2008-04 Thesis NonPeerReviewed text en http://eprints.uthm.edu.my/7084/1/24p%20MUKMIN%20ZAWAWI.pdf text en http://eprints.uthm.edu.my/7084/2/MUKMIN%20ZAWAWI%20COPYRIGHT%20DECLARATION.pdf text en http://eprints.uthm.edu.my/7084/3/MUKMIN%20ZAWAWI%20WATERMARK.pdf Zawawi, Mukmin (2008) Alarm design for SCADA system of assembly CELL-200 trainer. Masters thesis, Universiti Tun Hussein Malaysia.
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
English
English
topic TJ Mechanical engineering and machinery
TJ212-225 Control engineering systems. Automatic machinery (General)
spellingShingle TJ Mechanical engineering and machinery
TJ212-225 Control engineering systems. Automatic machinery (General)
Zawawi, Mukmin
Alarm design for SCADA system of assembly CELL-200 trainer
description Alarm systems play a vital role in maintaining the safe operation in process plant. Moreover, the safety and efficiency of a plant's operation is assured by the usage of a reliable and user friendly alarm system. In this project, the main objective is to introduce an alarm feature inside the SCADA system. Identification of suitable guidelines in designing a good alarm system display is also part of the project's objective. Introduction of alarm feature inside the SCADA system is done by putting the Supervisory Control and Data Acquisition (SCADA) system to Assembly Cell-200 Trainer. Here, the SCADA system is equipped with an alarm system as the mean to monitor and control the trainer. The alarm design adopts the available alarm system guidelines as to figure out and judge the most suitable guidelines to be applied in this project. This exercise proves that general guidelines (e.g., use of an alarm philosophy) are essential in developing this projects. However, detailed guidelines (e.g., colour coding and symbol features) should be used more carefully and consistent to ensure the creation of understandable and recognizable display. From this project, a properly designed alarm system is developed, which provides the operators with enough information to prevent any abnormalities, fault conditions or undesired errors in the plant. This project also summarizes the principal guidelines to consider when designing and developing alarms in SCADA environment.
format Thesis
author Zawawi, Mukmin
author_facet Zawawi, Mukmin
author_sort Zawawi, Mukmin
title Alarm design for SCADA system of assembly CELL-200 trainer
title_short Alarm design for SCADA system of assembly CELL-200 trainer
title_full Alarm design for SCADA system of assembly CELL-200 trainer
title_fullStr Alarm design for SCADA system of assembly CELL-200 trainer
title_full_unstemmed Alarm design for SCADA system of assembly CELL-200 trainer
title_sort alarm design for scada system of assembly cell-200 trainer
publishDate 2008
url http://eprints.uthm.edu.my/7084/1/24p%20MUKMIN%20ZAWAWI.pdf
http://eprints.uthm.edu.my/7084/2/MUKMIN%20ZAWAWI%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/7084/3/MUKMIN%20ZAWAWI%20WATERMARK.pdf
http://eprints.uthm.edu.my/7084/
_version_ 1738581574069256192
score 13.160551