Development of tubular cardiovascular phantom system for pulse transit time simulation

This paper presents on the development of a tubular cardiovascular phantom system to simulate pulse transit time (PTT). The PTT defined as the delay time between two pulses in one cardiac cycle has been shown to be promising method for cuffless continuous blood pressure (BP) measurement. However mos...

Full description

Saved in:
Bibliographic Details
Main Authors: Wan Zaki, Wan Suhaimizan, Correia, Ricardo, Korposh, Serhiy, Hayes-Gill, Barrie R., P. Morgan, Stephen
Format: Article
Language:English
Published: Blue Eyes Intelligence Engineering & Sciences Publication 2019
Subjects:
Online Access:http://eprints.uthm.edu.my/685/1/DNJ9684_ce335e9de7e75d7deb09798dcfe2b2b6.pdf
http://eprints.uthm.edu.my/685/
https://doi.org/10.35940/ijrte.B1051.0782S219
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.685
record_format eprints
spelling my.uthm.eprints.6852021-10-17T05:01:03Z http://eprints.uthm.edu.my/685/ Development of tubular cardiovascular phantom system for pulse transit time simulation Wan Zaki, Wan Suhaimizan Correia, Ricardo Korposh, Serhiy Hayes-Gill, Barrie R. P. Morgan, Stephen TK5101-6720 Telecommunication. Including telegraphy, telephone, radio, radar, television TK7800-8360 Electronics This paper presents on the development of a tubular cardiovascular phantom system to simulate pulse transit time (PTT). The PTT defined as the delay time between two pulses in one cardiac cycle has been shown to be promising method for cuffless continuous blood pressure (BP) measurement. However most of the PTT measurement was performed on human subjects, thus giving a difficulty in validating sensor performance due to variability of BP. Therefore, a cardiovascular phantom system was proposed for simulate the PTT measurement. An electronic controlled module was developed to control pump operation for pulse generation. Plastic optical fibre (POF) sensors were used to measure the pulse signal on the flexible tube and the results were compared with an in-line pressure sensor. In this experiment, the delay time between two pulses were calculated offline using Matlab software and correlated with pulse pressure. The result demonstrate that the pulse delay time recorded by both sensors decreased with increase of pulse rate and pulse pressure. These results on the phantom study showed similar pattern to the human model, thus indicating that the system is able to simulate PTT for sensor validation purposes. Blue Eyes Intelligence Engineering & Sciences Publication 2019 Article PeerReviewed text en http://eprints.uthm.edu.my/685/1/DNJ9684_ce335e9de7e75d7deb09798dcfe2b2b6.pdf Wan Zaki, Wan Suhaimizan and Correia, Ricardo and Korposh, Serhiy and Hayes-Gill, Barrie R. and P. Morgan, Stephen (2019) Development of tubular cardiovascular phantom system for pulse transit time simulation. International Journal of Recent Technology and Engineering (IJRTE), 8 (252). pp. 291-296. ISSN 2277-3878 https://doi.org/10.35940/ijrte.B1051.0782S219
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
topic TK5101-6720 Telecommunication. Including telegraphy, telephone, radio, radar, television
TK7800-8360 Electronics
spellingShingle TK5101-6720 Telecommunication. Including telegraphy, telephone, radio, radar, television
TK7800-8360 Electronics
Wan Zaki, Wan Suhaimizan
Correia, Ricardo
Korposh, Serhiy
Hayes-Gill, Barrie R.
P. Morgan, Stephen
Development of tubular cardiovascular phantom system for pulse transit time simulation
description This paper presents on the development of a tubular cardiovascular phantom system to simulate pulse transit time (PTT). The PTT defined as the delay time between two pulses in one cardiac cycle has been shown to be promising method for cuffless continuous blood pressure (BP) measurement. However most of the PTT measurement was performed on human subjects, thus giving a difficulty in validating sensor performance due to variability of BP. Therefore, a cardiovascular phantom system was proposed for simulate the PTT measurement. An electronic controlled module was developed to control pump operation for pulse generation. Plastic optical fibre (POF) sensors were used to measure the pulse signal on the flexible tube and the results were compared with an in-line pressure sensor. In this experiment, the delay time between two pulses were calculated offline using Matlab software and correlated with pulse pressure. The result demonstrate that the pulse delay time recorded by both sensors decreased with increase of pulse rate and pulse pressure. These results on the phantom study showed similar pattern to the human model, thus indicating that the system is able to simulate PTT for sensor validation purposes.
format Article
author Wan Zaki, Wan Suhaimizan
Correia, Ricardo
Korposh, Serhiy
Hayes-Gill, Barrie R.
P. Morgan, Stephen
author_facet Wan Zaki, Wan Suhaimizan
Correia, Ricardo
Korposh, Serhiy
Hayes-Gill, Barrie R.
P. Morgan, Stephen
author_sort Wan Zaki, Wan Suhaimizan
title Development of tubular cardiovascular phantom system for pulse transit time simulation
title_short Development of tubular cardiovascular phantom system for pulse transit time simulation
title_full Development of tubular cardiovascular phantom system for pulse transit time simulation
title_fullStr Development of tubular cardiovascular phantom system for pulse transit time simulation
title_full_unstemmed Development of tubular cardiovascular phantom system for pulse transit time simulation
title_sort development of tubular cardiovascular phantom system for pulse transit time simulation
publisher Blue Eyes Intelligence Engineering & Sciences Publication
publishDate 2019
url http://eprints.uthm.edu.my/685/1/DNJ9684_ce335e9de7e75d7deb09798dcfe2b2b6.pdf
http://eprints.uthm.edu.my/685/
https://doi.org/10.35940/ijrte.B1051.0782S219
_version_ 1738580769169735680
score 13.209306