Photoacoustic Technology for Biological Tissues Characterization

The existing PA imaging systems showed mixed performance in terms of imaging characteristic and signal-to-noise ratio (SNR). The aim of this work is to present the use of an in-house assembled photoacoustic (PA) system using a modulating laser beam of wavelength 633 nm for two-dimensional (2D) chara...

Full description

Saved in:
Bibliographic Details
Main Authors: Hui Ling, Chua, Huong, Audrey
Format: Article
Published: Institute of Advanced Engineering and Science 2020
Subjects:
Online Access:http://eprints.uthm.edu.my/6824/
https://doi.org/0.11591/eei.v9i6.xxxx
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.6824
record_format eprints
spelling my.uthm.eprints.68242022-03-28T01:25:34Z http://eprints.uthm.edu.my/6824/ Photoacoustic Technology for Biological Tissues Characterization Hui Ling, Chua Huong, Audrey TP248.13-248.65 Biotechnology The existing PA imaging systems showed mixed performance in terms of imaging characteristic and signal-to-noise ratio (SNR). The aim of this work is to present the use of an in-house assembled photoacoustic (PA) system using a modulating laser beam of wavelength 633 nm for two-dimensional (2D) characterization of biological tissues. The differentiation of the tissues in this work is based on differences in their light absorption, wherein the produced photoacoustic signal detected by a transducer was translated into phase value (Ф) that corresponds to the peak amplitude of tissue optical absorption. This research investigated variation in PA response between the considered different parts of chicken carcasses: fat, liver and muscle. This work found fat tissue to produce the strongest PA signals with mean ± standard deviation (SD) Ф = 2.09 ± 0.31 while muscle produced the least signal strength with Ф = 1.03 ± 0.17. This work attributes these observations and the presence of stripes pattern in 2D Ф images of fat and muscle to the differences in the optical and structural properties of these samples. In addition, a comparison has been made in an attempt to better assess the performance of the developed system with the related ones.This work concluded that the developed system may be useful as an alternative means in the noninvasive and label-free visualization and characterization of intact biological tissues in terms of their structural and physiological context in the future. Institute of Advanced Engineering and Science 2020 Article PeerReviewed Hui Ling, Chua and Huong, Audrey (2020) Photoacoustic Technology for Biological Tissues Characterization. Bulletin of Electrical Engineering and Informatics, 9 (6). pp. 1-8. ISSN 2302-9285 https://doi.org/0.11591/eei.v9i6.xxxx
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
topic TP248.13-248.65 Biotechnology
spellingShingle TP248.13-248.65 Biotechnology
Hui Ling, Chua
Huong, Audrey
Photoacoustic Technology for Biological Tissues Characterization
description The existing PA imaging systems showed mixed performance in terms of imaging characteristic and signal-to-noise ratio (SNR). The aim of this work is to present the use of an in-house assembled photoacoustic (PA) system using a modulating laser beam of wavelength 633 nm for two-dimensional (2D) characterization of biological tissues. The differentiation of the tissues in this work is based on differences in their light absorption, wherein the produced photoacoustic signal detected by a transducer was translated into phase value (Ф) that corresponds to the peak amplitude of tissue optical absorption. This research investigated variation in PA response between the considered different parts of chicken carcasses: fat, liver and muscle. This work found fat tissue to produce the strongest PA signals with mean ± standard deviation (SD) Ф = 2.09 ± 0.31 while muscle produced the least signal strength with Ф = 1.03 ± 0.17. This work attributes these observations and the presence of stripes pattern in 2D Ф images of fat and muscle to the differences in the optical and structural properties of these samples. In addition, a comparison has been made in an attempt to better assess the performance of the developed system with the related ones.This work concluded that the developed system may be useful as an alternative means in the noninvasive and label-free visualization and characterization of intact biological tissues in terms of their structural and physiological context in the future.
format Article
author Hui Ling, Chua
Huong, Audrey
author_facet Hui Ling, Chua
Huong, Audrey
author_sort Hui Ling, Chua
title Photoacoustic Technology for Biological Tissues Characterization
title_short Photoacoustic Technology for Biological Tissues Characterization
title_full Photoacoustic Technology for Biological Tissues Characterization
title_fullStr Photoacoustic Technology for Biological Tissues Characterization
title_full_unstemmed Photoacoustic Technology for Biological Tissues Characterization
title_sort photoacoustic technology for biological tissues characterization
publisher Institute of Advanced Engineering and Science
publishDate 2020
url http://eprints.uthm.edu.my/6824/
https://doi.org/0.11591/eei.v9i6.xxxx
_version_ 1738581539860512768
score 13.160551