Influence of Actuator Nozzle Angle on the Flow Characteristics in Pressurized-Metered Dose Inhaler Using CFD

Pressurized metered dose inhalers (pMDIs) are often used for the treatment of asthma and chronic obstructive pulmonary disease. This device is easy to carry, highly effective and extremely safe, allowing reliable, consistent dosage delivery, metered dose inhalers are the inhalation devices that doct...

Full description

Saved in:
Bibliographic Details
Main Authors: Abd Rahman, Muhammad Faqhrurrazi, Asmuin, Nor Zelawati, Taib, Ishkrizat, Hidayat Mat, Mohamad Nur, Khairulfuaad, Riyadhthusollehan
Format: Article
Language:English
Published: Penerbit Akademia Baru 2020
Subjects:
Online Access:http://eprints.uthm.edu.my/6822/1/AJ%202020%20%28435%29.pdf
http://eprints.uthm.edu.my/6822/
https://doi.org/10.37934/cfdl.12.6.6779
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.6822
record_format eprints
spelling my.uthm.eprints.68222022-03-28T01:22:26Z http://eprints.uthm.edu.my/6822/ Influence of Actuator Nozzle Angle on the Flow Characteristics in Pressurized-Metered Dose Inhaler Using CFD Abd Rahman, Muhammad Faqhrurrazi Asmuin, Nor Zelawati Taib, Ishkrizat Hidayat Mat, Mohamad Nur Khairulfuaad, Riyadhthusollehan TP Chemical technology Pressurized metered dose inhalers (pMDIs) are often used for the treatment of asthma and chronic obstructive pulmonary disease. This device is easy to carry, highly effective and extremely safe, allowing reliable, consistent dosage delivery, metered dose inhalers are the inhalation devices that doctors and patients can readily select from around the world. This pMDI inhaler system has a problem which is the particle does not penetrate into the alveolar. ANSYS Fluent Version 19.2 was used to find the best angle of the actuator nozzle by parametric analysis. Standard K-epsilon was used as the turbulence model with enhanced wall treatment function. Discrete phase model (DPM) was applied to represent the particle flow. The result shows the best actuator nozzle angle is 120-degree which affects the maximum magnitude of particle velocity. Penerbit Akademia Baru 2020 Article PeerReviewed text en http://eprints.uthm.edu.my/6822/1/AJ%202020%20%28435%29.pdf Abd Rahman, Muhammad Faqhrurrazi and Asmuin, Nor Zelawati and Taib, Ishkrizat and Hidayat Mat, Mohamad Nur and Khairulfuaad, Riyadhthusollehan (2020) Influence of Actuator Nozzle Angle on the Flow Characteristics in Pressurized-Metered Dose Inhaler Using CFD. CFD Letters, 12 (6). pp. 67-79. ISSN 21801363 https://doi.org/10.37934/cfdl.12.6.6779
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
topic TP Chemical technology
spellingShingle TP Chemical technology
Abd Rahman, Muhammad Faqhrurrazi
Asmuin, Nor Zelawati
Taib, Ishkrizat
Hidayat Mat, Mohamad Nur
Khairulfuaad, Riyadhthusollehan
Influence of Actuator Nozzle Angle on the Flow Characteristics in Pressurized-Metered Dose Inhaler Using CFD
description Pressurized metered dose inhalers (pMDIs) are often used for the treatment of asthma and chronic obstructive pulmonary disease. This device is easy to carry, highly effective and extremely safe, allowing reliable, consistent dosage delivery, metered dose inhalers are the inhalation devices that doctors and patients can readily select from around the world. This pMDI inhaler system has a problem which is the particle does not penetrate into the alveolar. ANSYS Fluent Version 19.2 was used to find the best angle of the actuator nozzle by parametric analysis. Standard K-epsilon was used as the turbulence model with enhanced wall treatment function. Discrete phase model (DPM) was applied to represent the particle flow. The result shows the best actuator nozzle angle is 120-degree which affects the maximum magnitude of particle velocity.
format Article
author Abd Rahman, Muhammad Faqhrurrazi
Asmuin, Nor Zelawati
Taib, Ishkrizat
Hidayat Mat, Mohamad Nur
Khairulfuaad, Riyadhthusollehan
author_facet Abd Rahman, Muhammad Faqhrurrazi
Asmuin, Nor Zelawati
Taib, Ishkrizat
Hidayat Mat, Mohamad Nur
Khairulfuaad, Riyadhthusollehan
author_sort Abd Rahman, Muhammad Faqhrurrazi
title Influence of Actuator Nozzle Angle on the Flow Characteristics in Pressurized-Metered Dose Inhaler Using CFD
title_short Influence of Actuator Nozzle Angle on the Flow Characteristics in Pressurized-Metered Dose Inhaler Using CFD
title_full Influence of Actuator Nozzle Angle on the Flow Characteristics in Pressurized-Metered Dose Inhaler Using CFD
title_fullStr Influence of Actuator Nozzle Angle on the Flow Characteristics in Pressurized-Metered Dose Inhaler Using CFD
title_full_unstemmed Influence of Actuator Nozzle Angle on the Flow Characteristics in Pressurized-Metered Dose Inhaler Using CFD
title_sort influence of actuator nozzle angle on the flow characteristics in pressurized-metered dose inhaler using cfd
publisher Penerbit Akademia Baru
publishDate 2020
url http://eprints.uthm.edu.my/6822/1/AJ%202020%20%28435%29.pdf
http://eprints.uthm.edu.my/6822/
https://doi.org/10.37934/cfdl.12.6.6779
_version_ 1738581539586834432
score 13.188404