A heat pipe is a simple heat transfer device that can transport large quantities of heat with a very small difference in temperature between the hot ends to the other end. In this case study, the concept of the condensation process of heat pipe is applied in order to perform dehumidification process...

Full description

Saved in:
Bibliographic Details
Main Author: Alfan, Norman Hafizi
Format: Thesis
Language:English
English
English
Published: 2013
Subjects:
Online Access:http://eprints.uthm.edu.my/6719/1/24p%20NORMAN%20HAFIZI%20ALFAN.pdf
http://eprints.uthm.edu.my/6719/2/NORMAN%20HAFIZI%20ALFAN%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/6719/3/NORMAN%20HAFIZI%20ALFAN%20WATERMARK.pdf
http://eprints.uthm.edu.my/6719/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.6719
record_format eprints
spelling my.uthm.eprints.67192022-03-14T02:14:50Z http://eprints.uthm.edu.my/6719/ Analysis of characteristic heat pipe as an efficient cooling heat transfer device Alfan, Norman Hafizi TJ Mechanical engineering and machinery TJ255-265 Heat engines A heat pipe is a simple heat transfer device that can transport large quantities of heat with a very small difference in temperature between the hot ends to the other end. In this case study, the concept of the condensation process of heat pipe is applied in order to perform dehumidification process to remove extra moisture inside the air. The objective of this study is to compare the efficiency between the primary heat pipe in evacuated condition and the secondary heat pipe with water as the working fluid in order to perform the dehumidification process. The heat pipe device had been divided into 2 samples of specimens. First specimen of heat pipe using air whiles the other one used water as the working fluid. These two pipes were made without the wick but dealing with inclination of angle to see the performance of the heat pipe. These two heat pipes were built without the wick but dealing with inclination of angle to see the performance of the heat pipe. Both pipes were built by the total length of 400mm length and 8mm diameter using copper as the pipe material. Gravity pumping was used with the inclination angle to pump back the working fluid back to the evaporator section. The heat pipe was positioned at different angles of 0°, 30°, 60° and 90° with the horizontal. To achieve the objective of this study, both pipes were studied experimental and simulation to find the most efficiency between the primary heat pipe and the secondary heat pipe. The important parameter involves in the case study are the Merit Number, M and Heat Transfer Coefficient. After performing the experiments and simulation, the objective of this case study is achieved, which showed the secondary heat pipe is more efficient as a cooling heat transfer device. 2013-06 Thesis NonPeerReviewed text en http://eprints.uthm.edu.my/6719/1/24p%20NORMAN%20HAFIZI%20ALFAN.pdf text en http://eprints.uthm.edu.my/6719/2/NORMAN%20HAFIZI%20ALFAN%20COPYRIGHT%20DECLARATION.pdf text en http://eprints.uthm.edu.my/6719/3/NORMAN%20HAFIZI%20ALFAN%20WATERMARK.pdf Alfan, Norman Hafizi (2013) Analysis of characteristic heat pipe as an efficient cooling heat transfer device. Masters thesis, Universiti Tun Hussein Malaysia.
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
English
English
topic TJ Mechanical engineering and machinery
TJ255-265 Heat engines
spellingShingle TJ Mechanical engineering and machinery
TJ255-265 Heat engines
Alfan, Norman Hafizi
Analysis of characteristic heat pipe as an efficient cooling heat transfer device
description A heat pipe is a simple heat transfer device that can transport large quantities of heat with a very small difference in temperature between the hot ends to the other end. In this case study, the concept of the condensation process of heat pipe is applied in order to perform dehumidification process to remove extra moisture inside the air. The objective of this study is to compare the efficiency between the primary heat pipe in evacuated condition and the secondary heat pipe with water as the working fluid in order to perform the dehumidification process. The heat pipe device had been divided into 2 samples of specimens. First specimen of heat pipe using air whiles the other one used water as the working fluid. These two pipes were made without the wick but dealing with inclination of angle to see the performance of the heat pipe. These two heat pipes were built without the wick but dealing with inclination of angle to see the performance of the heat pipe. Both pipes were built by the total length of 400mm length and 8mm diameter using copper as the pipe material. Gravity pumping was used with the inclination angle to pump back the working fluid back to the evaporator section. The heat pipe was positioned at different angles of 0°, 30°, 60° and 90° with the horizontal. To achieve the objective of this study, both pipes were studied experimental and simulation to find the most efficiency between the primary heat pipe and the secondary heat pipe. The important parameter involves in the case study are the Merit Number, M and Heat Transfer Coefficient. After performing the experiments and simulation, the objective of this case study is achieved, which showed the secondary heat pipe is more efficient as a cooling heat transfer device.
format Thesis
author Alfan, Norman Hafizi
author_facet Alfan, Norman Hafizi
author_sort Alfan, Norman Hafizi
title Analysis of characteristic heat pipe as an efficient cooling heat transfer device
title_short Analysis of characteristic heat pipe as an efficient cooling heat transfer device
title_full Analysis of characteristic heat pipe as an efficient cooling heat transfer device
title_fullStr Analysis of characteristic heat pipe as an efficient cooling heat transfer device
title_full_unstemmed Analysis of characteristic heat pipe as an efficient cooling heat transfer device
title_sort analysis of characteristic heat pipe as an efficient cooling heat transfer device
publishDate 2013
url http://eprints.uthm.edu.my/6719/1/24p%20NORMAN%20HAFIZI%20ALFAN.pdf
http://eprints.uthm.edu.my/6719/2/NORMAN%20HAFIZI%20ALFAN%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/6719/3/NORMAN%20HAFIZI%20ALFAN%20WATERMARK.pdf
http://eprints.uthm.edu.my/6719/
_version_ 1738581526785818624
score 13.160551