Comparative computational study of mechanical behavior in self-expanding femoropopliteal stents

The use of the stent to treat peripheral artery disease (PAD) is increased and the proportion of failures also increases. The femoropopliteal artery (FPA) experiences a high deformation ratio compared to the cardiovascular artery due to limp flexion and daily activities that could lead to stent fail...

Full description

Saved in:
Bibliographic Details
Main Authors: Kareem, AK, Fakhri, OM, Ismail, Al Emran, Taib, I, Ali, IR, Nemah, MN
Format: Article
Language:English
Published: Penerbit UTHM 2020
Subjects:
Online Access:http://eprints.uthm.edu.my/6181/1/AJ%202020%20%28229%29.pdf
http://eprints.uthm.edu.my/6181/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.6181
record_format eprints
spelling my.uthm.eprints.61812022-01-27T04:04:50Z http://eprints.uthm.edu.my/6181/ Comparative computational study of mechanical behavior in self-expanding femoropopliteal stents Kareem, AK Fakhri, OM Ismail, Al Emran Taib, I Ali, IR Nemah, MN TJ Mechanical engineering and machinery The use of the stent to treat peripheral artery disease (PAD) is increased and the proportion of failures also increases. The femoropopliteal artery (FPA) experiences a high deformation ratio compared to the cardiovascular artery due to limp flexion and daily activities that could lead to stent failure, as well as increasing the number of observed mortality and morbidity. In the present work, two of the common PAD stent design models represented as STENT I and STENT II were analyzed by using of finite element method (FEM) to simulate the most mechanical loading modes that could occur in FPA, such as axial tension and compression, torsion, three-point bending and radial compression to give a good understanding of deformation that affected stent inside the in-vivo. The gradual force load was used to simulate all modes, the force values are 0.25 N, 0.5 N, 1.5 N, 2.5 N, 3.5 N and 5.5 N until the stent models obtain the yield-point. The comparison of stent models (STENT I, STENT II) was performed in terms of graphs of total deformation, force-stress and stress-strain for all test modes. The similarity ratio of the total deformation in axial tension and the compression mode for STENT I and STENT II was 17% and that may indicate that STENT I obtained a high deformation value instead of STENT II, while, the torsion similarity ratio was 86% which could show a good agreement in this mode, as well as the similarity ratio, was 78% of the total three-point bending deformation and the value of the similarity ratio in the radial compression mode was 23%. Still unclear what is the clinical mode of mechanical deformation that is more important than others with changing the length of the lesion and stent diameter, and the fatigue life test provides a better understanding of the mechanical tests that must be sought. Penerbit UTHM 2020 Article PeerReviewed text en http://eprints.uthm.edu.my/6181/1/AJ%202020%20%28229%29.pdf Kareem, AK and Fakhri, OM and Ismail, Al Emran and Taib, I and Ali, IR and Nemah, MN (2020) Comparative computational study of mechanical behavior in self-expanding femoropopliteal stents. The International Journal of Integrated Engineering, 12 (1). pp. 210-224. ISSN 2229-838X
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Kareem, AK
Fakhri, OM
Ismail, Al Emran
Taib, I
Ali, IR
Nemah, MN
Comparative computational study of mechanical behavior in self-expanding femoropopliteal stents
description The use of the stent to treat peripheral artery disease (PAD) is increased and the proportion of failures also increases. The femoropopliteal artery (FPA) experiences a high deformation ratio compared to the cardiovascular artery due to limp flexion and daily activities that could lead to stent failure, as well as increasing the number of observed mortality and morbidity. In the present work, two of the common PAD stent design models represented as STENT I and STENT II were analyzed by using of finite element method (FEM) to simulate the most mechanical loading modes that could occur in FPA, such as axial tension and compression, torsion, three-point bending and radial compression to give a good understanding of deformation that affected stent inside the in-vivo. The gradual force load was used to simulate all modes, the force values are 0.25 N, 0.5 N, 1.5 N, 2.5 N, 3.5 N and 5.5 N until the stent models obtain the yield-point. The comparison of stent models (STENT I, STENT II) was performed in terms of graphs of total deformation, force-stress and stress-strain for all test modes. The similarity ratio of the total deformation in axial tension and the compression mode for STENT I and STENT II was 17% and that may indicate that STENT I obtained a high deformation value instead of STENT II, while, the torsion similarity ratio was 86% which could show a good agreement in this mode, as well as the similarity ratio, was 78% of the total three-point bending deformation and the value of the similarity ratio in the radial compression mode was 23%. Still unclear what is the clinical mode of mechanical deformation that is more important than others with changing the length of the lesion and stent diameter, and the fatigue life test provides a better understanding of the mechanical tests that must be sought.
format Article
author Kareem, AK
Fakhri, OM
Ismail, Al Emran
Taib, I
Ali, IR
Nemah, MN
author_facet Kareem, AK
Fakhri, OM
Ismail, Al Emran
Taib, I
Ali, IR
Nemah, MN
author_sort Kareem, AK
title Comparative computational study of mechanical behavior in self-expanding femoropopliteal stents
title_short Comparative computational study of mechanical behavior in self-expanding femoropopliteal stents
title_full Comparative computational study of mechanical behavior in self-expanding femoropopliteal stents
title_fullStr Comparative computational study of mechanical behavior in self-expanding femoropopliteal stents
title_full_unstemmed Comparative computational study of mechanical behavior in self-expanding femoropopliteal stents
title_sort comparative computational study of mechanical behavior in self-expanding femoropopliteal stents
publisher Penerbit UTHM
publishDate 2020
url http://eprints.uthm.edu.my/6181/1/AJ%202020%20%28229%29.pdf
http://eprints.uthm.edu.my/6181/
_version_ 1738581460428783616
score 13.160551