Reinforced concrete by using the rectangular shape of voided beam

In conventional RC beam, the transition from compression to tension zone of the beam when load applied producing ineffective region at the middle area of the neutral axis. This is because, the area experiencing less compression and tension compare to the region above and below the neutral axis. T...

Full description

Saved in:
Bibliographic Details
Main Authors: Idris, Nur’Ain, Mohd Noh, Hamidun, Mohamad, Nor Lailatul Izzatil Azwani, Bangau, Rolly
Format: Article
Language:English
Published: Universiti Teknologi MARA (UiTM), Malaysia 2020
Subjects:
Online Access:http://eprints.uthm.edu.my/5615/1/J10605_d1767e0a4fdb68541d47710f07287be1.pdf
http://eprints.uthm.edu.my/5615/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.5615
record_format eprints
spelling my.uthm.eprints.56152022-01-17T02:19:31Z http://eprints.uthm.edu.my/5615/ Reinforced concrete by using the rectangular shape of voided beam Idris, Nur’Ain Mohd Noh, Hamidun Mohamad, Nor Lailatul Izzatil Azwani Bangau, Rolly T Technology (General) TH1000-1725 Systems of building construction. Including fireproof construction, concrete construction In conventional RC beam, the transition from compression to tension zone of the beam when load applied producing ineffective region at the middle area of the neutral axis. This is because, the area experiencing less compression and tension compare to the region above and below the neutral axis. Thus, the purpose of this research is to replace the use of concrete at the middle of the neutral axis by incorporating 4 PVC pipes to reduce cost and the self-weight of the structure. 4 pipes with a diameter of 20mm, 25mm and 50mm will be combined together to form a continuous voided square beam of V40, V50 and V100. The size of RC beam specimens is 1200mm x 160mm x 160mm, these beams were test with 3-point load test to identify the flexural strength. From the test, the ordinary beam recorded lowest maximum load, which is 15,35kN and VRB 100mm is the strongest beam with the maximum load 33.75kN and has the highest strength increment compared to another voided rectangular beam. Besides that, VRB 100mm also can reduced until 42.69% self-weight of RC beam and reduce until 37.5% of the concrete usage. From this study, it shows that the Voided Square Beam can reduce the self-weight of beam and reduce the concrete usage. Besides that, this idea also can implement to produce the lightweight structure that meet the standard of Industrialized Building System (IBS). Universiti Teknologi MARA (UiTM), Malaysia 2020 Article PeerReviewed text en http://eprints.uthm.edu.my/5615/1/J10605_d1767e0a4fdb68541d47710f07287be1.pdf Idris, Nur’Ain and Mohd Noh, Hamidun and Mohamad, Nor Lailatul Izzatil Azwani and Bangau, Rolly (2020) Reinforced concrete by using the rectangular shape of voided beam. Journal of Mechanical Engineering, SI 9 (1). pp. 179-190. ISSN 1823-5514
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
topic T Technology (General)
TH1000-1725 Systems of building construction. Including fireproof construction, concrete construction
spellingShingle T Technology (General)
TH1000-1725 Systems of building construction. Including fireproof construction, concrete construction
Idris, Nur’Ain
Mohd Noh, Hamidun
Mohamad, Nor Lailatul Izzatil Azwani
Bangau, Rolly
Reinforced concrete by using the rectangular shape of voided beam
description In conventional RC beam, the transition from compression to tension zone of the beam when load applied producing ineffective region at the middle area of the neutral axis. This is because, the area experiencing less compression and tension compare to the region above and below the neutral axis. Thus, the purpose of this research is to replace the use of concrete at the middle of the neutral axis by incorporating 4 PVC pipes to reduce cost and the self-weight of the structure. 4 pipes with a diameter of 20mm, 25mm and 50mm will be combined together to form a continuous voided square beam of V40, V50 and V100. The size of RC beam specimens is 1200mm x 160mm x 160mm, these beams were test with 3-point load test to identify the flexural strength. From the test, the ordinary beam recorded lowest maximum load, which is 15,35kN and VRB 100mm is the strongest beam with the maximum load 33.75kN and has the highest strength increment compared to another voided rectangular beam. Besides that, VRB 100mm also can reduced until 42.69% self-weight of RC beam and reduce until 37.5% of the concrete usage. From this study, it shows that the Voided Square Beam can reduce the self-weight of beam and reduce the concrete usage. Besides that, this idea also can implement to produce the lightweight structure that meet the standard of Industrialized Building System (IBS).
format Article
author Idris, Nur’Ain
Mohd Noh, Hamidun
Mohamad, Nor Lailatul Izzatil Azwani
Bangau, Rolly
author_facet Idris, Nur’Ain
Mohd Noh, Hamidun
Mohamad, Nor Lailatul Izzatil Azwani
Bangau, Rolly
author_sort Idris, Nur’Ain
title Reinforced concrete by using the rectangular shape of voided beam
title_short Reinforced concrete by using the rectangular shape of voided beam
title_full Reinforced concrete by using the rectangular shape of voided beam
title_fullStr Reinforced concrete by using the rectangular shape of voided beam
title_full_unstemmed Reinforced concrete by using the rectangular shape of voided beam
title_sort reinforced concrete by using the rectangular shape of voided beam
publisher Universiti Teknologi MARA (UiTM), Malaysia
publishDate 2020
url http://eprints.uthm.edu.my/5615/1/J10605_d1767e0a4fdb68541d47710f07287be1.pdf
http://eprints.uthm.edu.my/5615/
_version_ 1738581397383151616
score 13.160551