High temperature fatigue characteristics of P/M and hot-forged W-Re and TZM for X-ray target of CT scanner

The fatigue strengths at 1000 °C of layered W-Re/TZM, bulk W-Re and bulk TZM for x-ray target materials were successfully evaluated under load-controlled four-point bending by introducing a fatigue failure criterion as twotimes increase of initial compliance. The obtained fatigue strengths at 1000 °...

Full description

Saved in:
Bibliographic Details
Main Authors: Harimon, Mohd Azhar, Miyashita, Yukio, Otsuka, Yuichi, Mutoh, Yoshiharu, Yamamoto, Shinichi
Format: Article
Language:English
Published: ScienceDirect 2018
Subjects:
Online Access:http://eprints.uthm.edu.my/4621/1/AJ%202018%20%28109%29.pdf
http://eprints.uthm.edu.my/4621/
https://doi.org/10.1016/j.matdes.2017.10.044
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.4621
record_format eprints
spelling my.uthm.eprints.46212021-12-07T09:08:40Z http://eprints.uthm.edu.my/4621/ High temperature fatigue characteristics of P/M and hot-forged W-Re and TZM for X-ray target of CT scanner Harimon, Mohd Azhar Miyashita, Yukio Otsuka, Yuichi Mutoh, Yoshiharu Yamamoto, Shinichi T Technology (General) TA401-492 Materials of engineering and construction. Mechanics of materials The fatigue strengths at 1000 °C of layered W-Re/TZM, bulk W-Re and bulk TZM for x-ray target materials were successfully evaluated under load-controlled four-point bending by introducing a fatigue failure criterion as twotimes increase of initial compliance. The obtained fatigue strengths at 1000 °C for layered W-Re/TZM and bulk WRe were similar and 280 MPa and 290 MPa at 106 cycles, respectively, while that of bulk TZM was 200 MPa. During fatigue loading at 1000 °C, dominant fatigue damage would be multiple intergranular crack nucleation and propagation, which would induce the increase of compliance. The reasonability of the fatigue failure criterion was confirmed by the fatigue process observations and the results of room temperature fatigue tests of the specimens tested at 1000 °C up to the cycles corresponding to the fatigue failure criterion. ScienceDirect 2018 Article PeerReviewed text en http://eprints.uthm.edu.my/4621/1/AJ%202018%20%28109%29.pdf Harimon, Mohd Azhar and Miyashita, Yukio and Otsuka, Yuichi and Mutoh, Yoshiharu and Yamamoto, Shinichi (2018) High temperature fatigue characteristics of P/M and hot-forged W-Re and TZM for X-ray target of CT scanner. Materials & Design, 137. pp. 335-344. ISSN 0261-3069 https://doi.org/10.1016/j.matdes.2017.10.044
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
topic T Technology (General)
TA401-492 Materials of engineering and construction. Mechanics of materials
spellingShingle T Technology (General)
TA401-492 Materials of engineering and construction. Mechanics of materials
Harimon, Mohd Azhar
Miyashita, Yukio
Otsuka, Yuichi
Mutoh, Yoshiharu
Yamamoto, Shinichi
High temperature fatigue characteristics of P/M and hot-forged W-Re and TZM for X-ray target of CT scanner
description The fatigue strengths at 1000 °C of layered W-Re/TZM, bulk W-Re and bulk TZM for x-ray target materials were successfully evaluated under load-controlled four-point bending by introducing a fatigue failure criterion as twotimes increase of initial compliance. The obtained fatigue strengths at 1000 °C for layered W-Re/TZM and bulk WRe were similar and 280 MPa and 290 MPa at 106 cycles, respectively, while that of bulk TZM was 200 MPa. During fatigue loading at 1000 °C, dominant fatigue damage would be multiple intergranular crack nucleation and propagation, which would induce the increase of compliance. The reasonability of the fatigue failure criterion was confirmed by the fatigue process observations and the results of room temperature fatigue tests of the specimens tested at 1000 °C up to the cycles corresponding to the fatigue failure criterion.
format Article
author Harimon, Mohd Azhar
Miyashita, Yukio
Otsuka, Yuichi
Mutoh, Yoshiharu
Yamamoto, Shinichi
author_facet Harimon, Mohd Azhar
Miyashita, Yukio
Otsuka, Yuichi
Mutoh, Yoshiharu
Yamamoto, Shinichi
author_sort Harimon, Mohd Azhar
title High temperature fatigue characteristics of P/M and hot-forged W-Re and TZM for X-ray target of CT scanner
title_short High temperature fatigue characteristics of P/M and hot-forged W-Re and TZM for X-ray target of CT scanner
title_full High temperature fatigue characteristics of P/M and hot-forged W-Re and TZM for X-ray target of CT scanner
title_fullStr High temperature fatigue characteristics of P/M and hot-forged W-Re and TZM for X-ray target of CT scanner
title_full_unstemmed High temperature fatigue characteristics of P/M and hot-forged W-Re and TZM for X-ray target of CT scanner
title_sort high temperature fatigue characteristics of p/m and hot-forged w-re and tzm for x-ray target of ct scanner
publisher ScienceDirect
publishDate 2018
url http://eprints.uthm.edu.my/4621/1/AJ%202018%20%28109%29.pdf
http://eprints.uthm.edu.my/4621/
https://doi.org/10.1016/j.matdes.2017.10.044
_version_ 1738581275670740992
score 13.160551