Mitigation of voltage sag caused by unbalanced load by using dft controlled dvr
This paper describes the source of voltage sag occurring in the power system. Voltage sag can occur in the system by means of having line faulty, inrush current drawn by loads and switching operation. However, the unbalanced load in the system causing voltage sag is studied here. In this paper,...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Subjects: | |
Online Access: | http://eprints.uthm.edu.my/4501/1/KP%202020%20%2890%29.pdf http://eprints.uthm.edu.my/4501/ http://DOI:10.1109/ICIRD47319.2019.9074727 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uthm.eprints.4501 |
---|---|
record_format |
eprints |
spelling |
my.uthm.eprints.45012022-01-23T07:55:23Z http://eprints.uthm.edu.my/4501/ Mitigation of voltage sag caused by unbalanced load by using dft controlled dvr Soomro, Dur Muhammad Wei Keat, Yew Baloch, Mazhar Hussain Abdullah, Mohd Noor Mohammad Radzi, Nur Hanis Ahmed Memon, Zubair TK3001-3521 Distribution or transmission of electric power This paper describes the source of voltage sag occurring in the power system. Voltage sag can occur in the system by means of having line faulty, inrush current drawn by loads and switching operation. However, the unbalanced load in the system causing voltage sag is studied here. In this paper, the pattern of voltage sag caused by balanced three phase (3Ø) and unbalanced single phase (1Ø) loads are studied and compared. The percentage of voltage sag caused by both cases are calculated using voltage sag calculation formulae by keeping definition values of sag between 10% - 90% as stated in IEEE Std. 1159-2009. While the percentage of voltage unbalance in the system caused by 1Ø unbalanced loads is calculated by using voltage unbalance formulae. The philosophy of voltage sag mitigation is studied by using a proposed mitigation device after studied the causes of voltage sag. There are several researches that have been done by proposing different kind of devices. The Dynamic Voltage Restorer (DVR) is one of the most cost-effective methods to protect the sensitive loads in the system for mitigating the voltage sag. The voltage sag is mitigated by injecting voltage dynamically to compensate the voltage differences between normal input supply and disturbed output supply. In order to achieve the voltage injection into the system dynamically to mitigate voltage sag, a control technique has to be applied on the DVR. There are many control techniques which are applied on the DVR to mitigate the voltage sag, such as the Direct-Quadrature-Zero (dq0), Fuzzy Logic (FL) and Space Vector Pulse Width Modulation (SVPWM). The Discrete Fourier Transform (DFT) is one of the control techniques which is implemented on the DVR in this paper. The modeling and simulation results of the DFT controlled DVR were carried out by using MATLAB/Simulink to validity the performance of the sag mitigation. As a result, the DFT controlled DVR was successfully designed and 100% mitigated the voltage sag both with balanced and unbalanced loads in the system. Conference or Workshop Item PeerReviewed text en http://eprints.uthm.edu.my/4501/1/KP%202020%20%2890%29.pdf Soomro, Dur Muhammad and Wei Keat, Yew and Baloch, Mazhar Hussain and Abdullah, Mohd Noor and Mohammad Radzi, Nur Hanis and Ahmed Memon, Zubair Mitigation of voltage sag caused by unbalanced load by using dft controlled dvr. In: 2019 IEEE International Conference on Innovative Research and Development (ICIRD), 28-30 June 2019, Jakarta, Indonesia. http://DOI:10.1109/ICIRD47319.2019.9074727 |
institution |
Universiti Tun Hussein Onn Malaysia |
building |
UTHM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tun Hussein Onn Malaysia |
content_source |
UTHM Institutional Repository |
url_provider |
http://eprints.uthm.edu.my/ |
language |
English |
topic |
TK3001-3521 Distribution or transmission of electric power |
spellingShingle |
TK3001-3521 Distribution or transmission of electric power Soomro, Dur Muhammad Wei Keat, Yew Baloch, Mazhar Hussain Abdullah, Mohd Noor Mohammad Radzi, Nur Hanis Ahmed Memon, Zubair Mitigation of voltage sag caused by unbalanced load by using dft controlled dvr |
description |
This paper describes the source of voltage sag
occurring in the power system. Voltage sag can occur in the
system by means of having line faulty, inrush current drawn by
loads and switching operation. However, the unbalanced load
in the system causing voltage sag is studied here. In this paper,
the pattern of voltage sag caused by balanced three phase (3Ø)
and unbalanced single phase (1Ø) loads are studied and
compared. The percentage of voltage sag caused by both cases
are calculated using voltage sag calculation formulae by
keeping definition values of sag between 10% - 90% as stated
in IEEE Std. 1159-2009. While the percentage of voltage
unbalance in the system caused by 1Ø unbalanced loads is
calculated by using voltage unbalance formulae. The
philosophy of voltage sag mitigation is studied by using a
proposed mitigation device after studied the causes of voltage
sag. There are several researches that have been done by
proposing different kind of devices. The Dynamic Voltage
Restorer (DVR) is one of the most cost-effective methods to
protect the sensitive loads in the system for mitigating the
voltage sag. The voltage sag is mitigated by injecting voltage
dynamically to compensate the voltage differences between
normal input supply and disturbed output supply. In order to
achieve the voltage injection into the system dynamically to
mitigate voltage sag, a control technique has to be applied on
the DVR. There are many control techniques which are
applied on the DVR to mitigate the voltage sag, such as the
Direct-Quadrature-Zero (dq0), Fuzzy Logic (FL) and Space
Vector Pulse Width Modulation (SVPWM). The Discrete
Fourier Transform (DFT) is one of the control techniques
which is implemented on the DVR in this paper. The modeling
and simulation results of the DFT controlled DVR were carried
out by using MATLAB/Simulink to validity the performance of
the sag mitigation. As a result, the DFT controlled DVR was
successfully designed and 100% mitigated the voltage sag both
with balanced and unbalanced loads in the system. |
format |
Conference or Workshop Item |
author |
Soomro, Dur Muhammad Wei Keat, Yew Baloch, Mazhar Hussain Abdullah, Mohd Noor Mohammad Radzi, Nur Hanis Ahmed Memon, Zubair |
author_facet |
Soomro, Dur Muhammad Wei Keat, Yew Baloch, Mazhar Hussain Abdullah, Mohd Noor Mohammad Radzi, Nur Hanis Ahmed Memon, Zubair |
author_sort |
Soomro, Dur Muhammad |
title |
Mitigation of voltage sag caused by unbalanced load by using dft controlled dvr |
title_short |
Mitigation of voltage sag caused by unbalanced load by using dft controlled dvr |
title_full |
Mitigation of voltage sag caused by unbalanced load by using dft controlled dvr |
title_fullStr |
Mitigation of voltage sag caused by unbalanced load by using dft controlled dvr |
title_full_unstemmed |
Mitigation of voltage sag caused by unbalanced load by using dft controlled dvr |
title_sort |
mitigation of voltage sag caused by unbalanced load by using dft controlled dvr |
url |
http://eprints.uthm.edu.my/4501/1/KP%202020%20%2890%29.pdf http://eprints.uthm.edu.my/4501/ http://DOI:10.1109/ICIRD47319.2019.9074727 |
_version_ |
1738581258653401088 |
score |
13.211869 |