Structural performance of recycled aggregate in CSP slab subjected to flexure load

This paper discusses the mechanical properties of recycled aggregate concrete (RAC) and its performance in concrete sandwich precast (CSP) slab subjected to flexure load. Various percentage of recycle aggregate (RA) was used in the concrete mixture as a replacement to natural aggregate; namely 25%...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohamad, Noridah, Abdul Samad, Abdul Aziz, Goh, Wan Inn, Mendis, Priyan, Hamza, Khalifa
Format: Article
Language:English
Published: Elsevier Ltd. 2016
Subjects:
Online Access:http://eprints.uthm.edu.my/4495/1/AJ%202016%20%2846%29.pdf
http://eprints.uthm.edu.my/4495/
http://dx.doi.org/10.1016/j.conbuildmat.2016.04.086
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.4495
record_format eprints
spelling my.uthm.eprints.44952021-12-07T04:18:40Z http://eprints.uthm.edu.my/4495/ Structural performance of recycled aggregate in CSP slab subjected to flexure load Mohamad, Noridah Abdul Samad, Abdul Aziz Goh, Wan Inn Mendis, Priyan Hamza, Khalifa T Technology (General) TA401-492 Materials of engineering and construction. Mechanics of materials This paper discusses the mechanical properties of recycled aggregate concrete (RAC) and its performance in concrete sandwich precast (CSP) slab subjected to flexure load. Various percentage of recycle aggregate (RA) was used in the concrete mixture as a replacement to natural aggregate; namely 25%, 50%, 75% and 100%. The structural behavior of the CSP slab was investigated experimentally under flexure load and analyzed in the context of its ultimate load capacity, crack pattern, load-deflection profile and load-slip profile. Analysis from the results showed that the percentage of RA used has a small effect on the mechanical properties of RAC but quite significant effect on the structural behavior of CSP slab under flexure. It was found that the strength of the panels with RAC decreased with the increase of RA in the concrete. The percentage of reduction in the ultimate load of slab panels with RA was about 15% for every 25% percentage increase of RA. The first crack occurred at about 48–67% of the failure load and panels failed with excessive cracks in the tension zone of the bottom wythe. All tested panels proved to be very ductile with large deformation prior to failure and behaved in a partially composite manner. Elsevier Ltd. 2016 Article PeerReviewed text en http://eprints.uthm.edu.my/4495/1/AJ%202016%20%2846%29.pdf Mohamad, Noridah and Abdul Samad, Abdul Aziz and Goh, Wan Inn and Mendis, Priyan and Hamza, Khalifa (2016) Structural performance of recycled aggregate in CSP slab subjected to flexure load. Construction and Building Materials, 115. pp. 669-680. ISSN 0950-0618 http://dx.doi.org/10.1016/j.conbuildmat.2016.04.086
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
topic T Technology (General)
TA401-492 Materials of engineering and construction. Mechanics of materials
spellingShingle T Technology (General)
TA401-492 Materials of engineering and construction. Mechanics of materials
Mohamad, Noridah
Abdul Samad, Abdul Aziz
Goh, Wan Inn
Mendis, Priyan
Hamza, Khalifa
Structural performance of recycled aggregate in CSP slab subjected to flexure load
description This paper discusses the mechanical properties of recycled aggregate concrete (RAC) and its performance in concrete sandwich precast (CSP) slab subjected to flexure load. Various percentage of recycle aggregate (RA) was used in the concrete mixture as a replacement to natural aggregate; namely 25%, 50%, 75% and 100%. The structural behavior of the CSP slab was investigated experimentally under flexure load and analyzed in the context of its ultimate load capacity, crack pattern, load-deflection profile and load-slip profile. Analysis from the results showed that the percentage of RA used has a small effect on the mechanical properties of RAC but quite significant effect on the structural behavior of CSP slab under flexure. It was found that the strength of the panels with RAC decreased with the increase of RA in the concrete. The percentage of reduction in the ultimate load of slab panels with RA was about 15% for every 25% percentage increase of RA. The first crack occurred at about 48–67% of the failure load and panels failed with excessive cracks in the tension zone of the bottom wythe. All tested panels proved to be very ductile with large deformation prior to failure and behaved in a partially composite manner.
format Article
author Mohamad, Noridah
Abdul Samad, Abdul Aziz
Goh, Wan Inn
Mendis, Priyan
Hamza, Khalifa
author_facet Mohamad, Noridah
Abdul Samad, Abdul Aziz
Goh, Wan Inn
Mendis, Priyan
Hamza, Khalifa
author_sort Mohamad, Noridah
title Structural performance of recycled aggregate in CSP slab subjected to flexure load
title_short Structural performance of recycled aggregate in CSP slab subjected to flexure load
title_full Structural performance of recycled aggregate in CSP slab subjected to flexure load
title_fullStr Structural performance of recycled aggregate in CSP slab subjected to flexure load
title_full_unstemmed Structural performance of recycled aggregate in CSP slab subjected to flexure load
title_sort structural performance of recycled aggregate in csp slab subjected to flexure load
publisher Elsevier Ltd.
publishDate 2016
url http://eprints.uthm.edu.my/4495/1/AJ%202016%20%2846%29.pdf
http://eprints.uthm.edu.my/4495/
http://dx.doi.org/10.1016/j.conbuildmat.2016.04.086
_version_ 1738581257893183488
score 13.18916