Real time power control strategy for output power for single phase inverter-linear load
Power electronics have been widely used in many applications due to its reliability in controller. This project is to describe and test the real time power control strategy for output power for inverter-linear load connection. The current control strategy was adapted in controlling the output power...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English English English |
Published: |
2019
|
Subjects: | |
Online Access: | http://eprints.uthm.edu.my/441/1/24p%20AHMAD%20NAJI%20ZAIDAN.pdf http://eprints.uthm.edu.my/441/2/AHMAD%20NAJI%20ZAIDAN%20COPYRIGHT%20DECLARATION.pdf http://eprints.uthm.edu.my/441/3/AHMAD%20NAJI%20ZAIDAN%20WATERMARK.pdf http://eprints.uthm.edu.my/441/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uthm.eprints.441 |
---|---|
record_format |
eprints |
spelling |
my.uthm.eprints.4412021-07-25T06:26:31Z http://eprints.uthm.edu.my/441/ Real time power control strategy for output power for single phase inverter-linear load Zaidan, Ahmed Naji TK1001-1841 Production of electric energy or power. Powerplants. Central stations Power electronics have been widely used in many applications due to its reliability in controller. This project is to describe and test the real time power control strategy for output power for inverter-linear load connection. The current control strategy was adapted in controlling the output power of inverter to the resistive load. This was done by controlling the output current of the inverter. The output current was controlled by comparing between desired value with the target reference current. The feedback signal from the current output was processed by the microcontroller through the current sensor. The Texas Instrument C2000 microcontroller was used. The justification of this choice was its ability to convert the signal of the current sensor from analog to digital directly from the microcontroller. The controller used was developed from Proportional integral (PI) controller theory using the MATLAB SIMULINK software. At the end, the output power of the inverter was able to control the output current of the inverter as designed. The results obtained reflects a single phase inverter with a controlled output power at the desired value. This is an indication that the output current of inverter was controlled. 2019-01 Thesis NonPeerReviewed text en http://eprints.uthm.edu.my/441/1/24p%20AHMAD%20NAJI%20ZAIDAN.pdf text en http://eprints.uthm.edu.my/441/2/AHMAD%20NAJI%20ZAIDAN%20COPYRIGHT%20DECLARATION.pdf text en http://eprints.uthm.edu.my/441/3/AHMAD%20NAJI%20ZAIDAN%20WATERMARK.pdf Zaidan, Ahmed Naji (2019) Real time power control strategy for output power for single phase inverter-linear load. Masters thesis, Universiti Tun Hussein Onn Malaysia. |
institution |
Universiti Tun Hussein Onn Malaysia |
building |
UTHM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tun Hussein Onn Malaysia |
content_source |
UTHM Institutional Repository |
url_provider |
http://eprints.uthm.edu.my/ |
language |
English English English |
topic |
TK1001-1841 Production of electric energy or power. Powerplants. Central stations |
spellingShingle |
TK1001-1841 Production of electric energy or power. Powerplants. Central stations Zaidan, Ahmed Naji Real time power control strategy for output power for single phase inverter-linear load |
description |
Power electronics have been widely used in many applications due to its reliability in controller. This project is to describe and test the real time power control strategy for output power for inverter-linear load connection. The current control strategy was adapted in controlling the output power of inverter to the resistive load. This was done by controlling the output current of the inverter. The output current was controlled by comparing between desired value with the target reference current. The feedback signal from the current output was processed by the microcontroller through the current sensor. The Texas Instrument C2000 microcontroller was used. The justification of this choice was its ability to convert the signal of the current sensor from analog to digital directly from the microcontroller. The controller used was developed from Proportional integral (PI) controller theory using the MATLAB SIMULINK software. At the end, the output power of the inverter was able to control the output current of the inverter as designed. The results obtained reflects a single phase inverter with a controlled output power at the desired value. This is an indication that the output current of inverter was controlled. |
format |
Thesis |
author |
Zaidan, Ahmed Naji |
author_facet |
Zaidan, Ahmed Naji |
author_sort |
Zaidan, Ahmed Naji |
title |
Real time power control strategy for output power for single phase inverter-linear load |
title_short |
Real time power control strategy for output power for single phase inverter-linear load |
title_full |
Real time power control strategy for output power for single phase inverter-linear load |
title_fullStr |
Real time power control strategy for output power for single phase inverter-linear load |
title_full_unstemmed |
Real time power control strategy for output power for single phase inverter-linear load |
title_sort |
real time power control strategy for output power for single phase inverter-linear load |
publishDate |
2019 |
url |
http://eprints.uthm.edu.my/441/1/24p%20AHMAD%20NAJI%20ZAIDAN.pdf http://eprints.uthm.edu.my/441/2/AHMAD%20NAJI%20ZAIDAN%20COPYRIGHT%20DECLARATION.pdf http://eprints.uthm.edu.my/441/3/AHMAD%20NAJI%20ZAIDAN%20WATERMARK.pdf http://eprints.uthm.edu.my/441/ |
_version_ |
1738580737032978432 |
score |
13.149126 |