Lumped parameter modelling in femoral popliteal artery for normal and severe conditions

Development of numerical technique would be benefited to diagnose the biological structure especially in femoropopliteal artery. Blood circulatory system and heart hemodynamic performance can be simulated by applying lumped parameter method. Thus, this study aims to develop numerical modelling in fe...

Full description

Saved in:
Bibliographic Details
Main Authors: Kaha, Asrizan, Taib, Ishkrizat, Paisal, Muhammad Sufyan Amir, Tajul Arifin, Ahmad Mubarak, Ismail, Al Emran, Asmuin, Norzelawati, Abdul Haq, Reazul Haq, Chatpun, Surapong, Yamamoto, Takahisa, Osman, Kahar
Format: Article
Language:English
Published: Penerbit UTHM 2018
Subjects:
Online Access:http://eprints.uthm.edu.my/3617/1/AJ%202019%20%28152%29.pdf
http://eprints.uthm.edu.my/3617/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.3617
record_format eprints
spelling my.uthm.eprints.36172021-11-21T03:39:18Z http://eprints.uthm.edu.my/3617/ Lumped parameter modelling in femoral popliteal artery for normal and severe conditions Kaha, Asrizan Taib, Ishkrizat Paisal, Muhammad Sufyan Amir Tajul Arifin, Ahmad Mubarak Ismail, Al Emran Asmuin, Norzelawati Abdul Haq, Reazul Haq Chatpun, Surapong Yamamoto, Takahisa Osman, Kahar TK7800-8360 Electronics Development of numerical technique would be benefited to diagnose the biological structure especially in femoropopliteal artery. Blood circulatory system and heart hemodynamic performance can be simulated by applying lumped parameter method. Thus, this study aims to develop numerical modelling in femoropopliteal artery by constructing an electric analog model to the system. Three different cases have been considered in this study; normal blood condition, aneurysm and atherosclerosis conditions. Normal blood condition is also analysed as a basis study of comparison between aneurysm and atherosclerosis conditions. The electrical analog model with 3 nodes and terminal load at the end of this model are proposed. This algorithm is then verified against numerical data simulated using commercial software. The study shows that normal and abnormal conditions effect instantaneously to pressure and flow waveforms. The result shows that the highest peak pressure is shown in atherosclerosis condition about 3.2×105 Pa as compared to normal and aneurysm conditions which obtained about 1.7×104 Pa and 0.1×104 Pa, respectively. On the other hand, the flow resistance increase about 16 fold as the radius in aneurysm at 3.0 mm is reduced to 1.4 mm for the aneurysm condition. Therefore, the aneurysm condition in the second segment shows the highest flow rate about 3.0×10-3m3/s as compared to the other conditions. In conclusion, the obtained waveform propagation from the linear analysis of the lumped parameter modelling shows that the periodic mean pressures and flow rate distributions in large arteries are highly depend on the resistances and the compliances. The quantitative variations of blood pressure and flow waveforms along the arterial of femoral popliteal artery from this model followed clinical trends as the normal condition show a stable pressure and flow rate obtained compare to the atherosclerosis and aneurysm condition. Penerbit UTHM 2018 Article PeerReviewed text en http://eprints.uthm.edu.my/3617/1/AJ%202019%20%28152%29.pdf Kaha, Asrizan and Taib, Ishkrizat and Paisal, Muhammad Sufyan Amir and Tajul Arifin, Ahmad Mubarak and Ismail, Al Emran and Asmuin, Norzelawati and Abdul Haq, Reazul Haq and Chatpun, Surapong and Yamamoto, Takahisa and Osman, Kahar (2018) Lumped parameter modelling in femoral popliteal artery for normal and severe conditions. International Journal of Integrated Engineering: Special issue 2018: Mechanical Engineering, 10 (5). pp. 193-203. ISSN 2229-838X
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
topic TK7800-8360 Electronics
spellingShingle TK7800-8360 Electronics
Kaha, Asrizan
Taib, Ishkrizat
Paisal, Muhammad Sufyan Amir
Tajul Arifin, Ahmad Mubarak
Ismail, Al Emran
Asmuin, Norzelawati
Abdul Haq, Reazul Haq
Chatpun, Surapong
Yamamoto, Takahisa
Osman, Kahar
Lumped parameter modelling in femoral popliteal artery for normal and severe conditions
description Development of numerical technique would be benefited to diagnose the biological structure especially in femoropopliteal artery. Blood circulatory system and heart hemodynamic performance can be simulated by applying lumped parameter method. Thus, this study aims to develop numerical modelling in femoropopliteal artery by constructing an electric analog model to the system. Three different cases have been considered in this study; normal blood condition, aneurysm and atherosclerosis conditions. Normal blood condition is also analysed as a basis study of comparison between aneurysm and atherosclerosis conditions. The electrical analog model with 3 nodes and terminal load at the end of this model are proposed. This algorithm is then verified against numerical data simulated using commercial software. The study shows that normal and abnormal conditions effect instantaneously to pressure and flow waveforms. The result shows that the highest peak pressure is shown in atherosclerosis condition about 3.2×105 Pa as compared to normal and aneurysm conditions which obtained about 1.7×104 Pa and 0.1×104 Pa, respectively. On the other hand, the flow resistance increase about 16 fold as the radius in aneurysm at 3.0 mm is reduced to 1.4 mm for the aneurysm condition. Therefore, the aneurysm condition in the second segment shows the highest flow rate about 3.0×10-3m3/s as compared to the other conditions. In conclusion, the obtained waveform propagation from the linear analysis of the lumped parameter modelling shows that the periodic mean pressures and flow rate distributions in large arteries are highly depend on the resistances and the compliances. The quantitative variations of blood pressure and flow waveforms along the arterial of femoral popliteal artery from this model followed clinical trends as the normal condition show a stable pressure and flow rate obtained compare to the atherosclerosis and aneurysm condition.
format Article
author Kaha, Asrizan
Taib, Ishkrizat
Paisal, Muhammad Sufyan Amir
Tajul Arifin, Ahmad Mubarak
Ismail, Al Emran
Asmuin, Norzelawati
Abdul Haq, Reazul Haq
Chatpun, Surapong
Yamamoto, Takahisa
Osman, Kahar
author_facet Kaha, Asrizan
Taib, Ishkrizat
Paisal, Muhammad Sufyan Amir
Tajul Arifin, Ahmad Mubarak
Ismail, Al Emran
Asmuin, Norzelawati
Abdul Haq, Reazul Haq
Chatpun, Surapong
Yamamoto, Takahisa
Osman, Kahar
author_sort Kaha, Asrizan
title Lumped parameter modelling in femoral popliteal artery for normal and severe conditions
title_short Lumped parameter modelling in femoral popliteal artery for normal and severe conditions
title_full Lumped parameter modelling in femoral popliteal artery for normal and severe conditions
title_fullStr Lumped parameter modelling in femoral popliteal artery for normal and severe conditions
title_full_unstemmed Lumped parameter modelling in femoral popliteal artery for normal and severe conditions
title_sort lumped parameter modelling in femoral popliteal artery for normal and severe conditions
publisher Penerbit UTHM
publishDate 2018
url http://eprints.uthm.edu.my/3617/1/AJ%202019%20%28152%29.pdf
http://eprints.uthm.edu.my/3617/
_version_ 1738581146363494400
score 13.18916