Response surface methodology for modeling bisphenol A removal using ultrafiltration membrane system

In this work, the effects of various operating parameters (pressure, pH, BPA concentration, and filtration time) toward bisphenol A (BPA) removal via ultrafiltration (UF) membrane system were investigated using response surface methodology (RSM). Historical data design of RSM was used to obtain the...

Full description

Saved in:
Bibliographic Details
Main Authors: Muhamad, Mimi Suliza, Hamidon, Nuramidah, Salim, Mohd Razman, Yusop, Zulkifli, Lau, Woei Jye, Hadibarata, Tony
Format: Article
Language:English
Published: Springer
Subjects:
Online Access:http://eprints.uthm.edu.my/3577/1/AJ%202018%20%28361%29.pdf
http://eprints.uthm.edu.my/3577/
https://doi.org/10.1007/s11270-018-3875-1
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.3577
record_format eprints
spelling my.uthm.eprints.35772021-11-21T02:43:59Z http://eprints.uthm.edu.my/3577/ Response surface methodology for modeling bisphenol A removal using ultrafiltration membrane system Muhamad, Mimi Suliza Hamidon, Nuramidah Salim, Mohd Razman Yusop, Zulkifli Lau, Woei Jye Hadibarata, Tony TP Chemical technology TP155-156 Chemical engineering In this work, the effects of various operating parameters (pressure, pH, BPA concentration, and filtration time) toward bisphenol A (BPA) removal via ultrafiltration (UF) membrane system were investigated using response surface methodology (RSM). Historical data design of RSM was used to obtain the interaction between variables and response as well as optimizing the process. The analysis of variance (ANOVA) showed that the third-order polynomial model was significant in which pH and filtration time were identified as significant terms that influence BPA removal. The 3D response surface plots revealed the two-factor interaction between independent and dependent variables. The optimization process of the model predicted optimum conditions of 99.61% BPA removal at 1 bar, pH 6.7, 10 μg/L BPA concentration, and 10-min filtration time. The predicted optimum conditions for BPA removal were consistent with the obtained experimental values, indicating reliable application of historical data design RSM for modeling BPA removal in UF membrane system. Springer Article PeerReviewed text en http://eprints.uthm.edu.my/3577/1/AJ%202018%20%28361%29.pdf Muhamad, Mimi Suliza and Hamidon, Nuramidah and Salim, Mohd Razman and Yusop, Zulkifli and Lau, Woei Jye and Hadibarata, Tony Response surface methodology for modeling bisphenol A removal using ultrafiltration membrane system. Water Air Soil Pollution, 7 (1). pp. 1-11. ISSN 1573-2932 https://doi.org/10.1007/s11270-018-3875-1
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
topic TP Chemical technology
TP155-156 Chemical engineering
spellingShingle TP Chemical technology
TP155-156 Chemical engineering
Muhamad, Mimi Suliza
Hamidon, Nuramidah
Salim, Mohd Razman
Yusop, Zulkifli
Lau, Woei Jye
Hadibarata, Tony
Response surface methodology for modeling bisphenol A removal using ultrafiltration membrane system
description In this work, the effects of various operating parameters (pressure, pH, BPA concentration, and filtration time) toward bisphenol A (BPA) removal via ultrafiltration (UF) membrane system were investigated using response surface methodology (RSM). Historical data design of RSM was used to obtain the interaction between variables and response as well as optimizing the process. The analysis of variance (ANOVA) showed that the third-order polynomial model was significant in which pH and filtration time were identified as significant terms that influence BPA removal. The 3D response surface plots revealed the two-factor interaction between independent and dependent variables. The optimization process of the model predicted optimum conditions of 99.61% BPA removal at 1 bar, pH 6.7, 10 μg/L BPA concentration, and 10-min filtration time. The predicted optimum conditions for BPA removal were consistent with the obtained experimental values, indicating reliable application of historical data design RSM for modeling BPA removal in UF membrane system.
format Article
author Muhamad, Mimi Suliza
Hamidon, Nuramidah
Salim, Mohd Razman
Yusop, Zulkifli
Lau, Woei Jye
Hadibarata, Tony
author_facet Muhamad, Mimi Suliza
Hamidon, Nuramidah
Salim, Mohd Razman
Yusop, Zulkifli
Lau, Woei Jye
Hadibarata, Tony
author_sort Muhamad, Mimi Suliza
title Response surface methodology for modeling bisphenol A removal using ultrafiltration membrane system
title_short Response surface methodology for modeling bisphenol A removal using ultrafiltration membrane system
title_full Response surface methodology for modeling bisphenol A removal using ultrafiltration membrane system
title_fullStr Response surface methodology for modeling bisphenol A removal using ultrafiltration membrane system
title_full_unstemmed Response surface methodology for modeling bisphenol A removal using ultrafiltration membrane system
title_sort response surface methodology for modeling bisphenol a removal using ultrafiltration membrane system
publisher Springer
url http://eprints.uthm.edu.my/3577/1/AJ%202018%20%28361%29.pdf
http://eprints.uthm.edu.my/3577/
https://doi.org/10.1007/s11270-018-3875-1
_version_ 1738581140930822144
score 13.160551