Investigation of film cooling effectiveness from cylindrical cooling hole with anti vortex generator by numerical simulation

This study deals numerical study of the effect of anti vortex generator (AVG) on the film cooling performance of a circular cooling hole which has diameter (d = 20 mm) on a flat plate. The interaction between the jet cooling air and mainstream will result kidney vortex which will eliminate the fi...

Full description

Saved in:
Bibliographic Details
Main Author: Abu Zarida, Abdallah Ali
Format: Thesis
Language:English
English
English
Published: 2015
Subjects:
Online Access:http://eprints.uthm.edu.my/1246/2/ABDALLAH%20ALI%20ABU%20ZARIDA%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/1246/1/24p%20ABDALLAH%20ALI%20ABU%20ZARIDA.pdf
http://eprints.uthm.edu.my/1246/3/ABDALLAH%20ALI%20ABU%20ZARIDA%20WATERMARK.pdf
http://eprints.uthm.edu.my/1246/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.1246
record_format eprints
spelling my.uthm.eprints.12462021-09-30T06:40:53Z http://eprints.uthm.edu.my/1246/ Investigation of film cooling effectiveness from cylindrical cooling hole with anti vortex generator by numerical simulation Abu Zarida, Abdallah Ali TJ751-805 Miscellaneous motors and engines Including gas, gasoline, diesel engines This study deals numerical study of the effect of anti vortex generator (AVG) on the film cooling performance of a circular cooling hole which has diameter (d = 20 mm) on a flat plate. The interaction between the jet cooling air and mainstream will result kidney vortex which will eliminate the film cooling effectiveness. Two types of AVG with different heights (H = 0.5 d and 0.25 d) are designed to eliminate the kidney vortex and investigate best film cooling effectiveness, where each of them is mounted to the flat plate upstream of the cooling hole by changing its lateral positions (A = 0.0 d, 0.25 d, 0.5 d and 0.75 d) with respect to the hole centerline and for each type has different distance respect to hole centerline. The changing of blowing ratio (BR = 0.5-1.5) was considered in this study. As for the validation, the present study was compared with the previous research done by other researchers using the results obtained from experimental data. The steady turbulence model shear stress transport (SST) that was used to simulate a film cooling configuration. The results have been presented in terms of laterally averaged film cooling comparison graphs, velocity field on x/d = 3.0, non-dimensional temperature on x/d = 3.0 and the vorticity on x/d = 3.0 which explained how the results obtained. Cases 04 and 07 gave the best positions for AVG where case 04 gave wide covered for laterally average film cooling effectiveness , while case 07 gave the highest expand distribution and the maximum value for film cooling effectiveness . 2015-07 Thesis NonPeerReviewed text en http://eprints.uthm.edu.my/1246/2/ABDALLAH%20ALI%20ABU%20ZARIDA%20COPYRIGHT%20DECLARATION.pdf text en http://eprints.uthm.edu.my/1246/1/24p%20ABDALLAH%20ALI%20ABU%20ZARIDA.pdf text en http://eprints.uthm.edu.my/1246/3/ABDALLAH%20ALI%20ABU%20ZARIDA%20WATERMARK.pdf Abu Zarida, Abdallah Ali (2015) Investigation of film cooling effectiveness from cylindrical cooling hole with anti vortex generator by numerical simulation. Masters thesis, UTHM.
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
English
English
topic TJ751-805 Miscellaneous motors and engines Including gas, gasoline, diesel engines
spellingShingle TJ751-805 Miscellaneous motors and engines Including gas, gasoline, diesel engines
Abu Zarida, Abdallah Ali
Investigation of film cooling effectiveness from cylindrical cooling hole with anti vortex generator by numerical simulation
description This study deals numerical study of the effect of anti vortex generator (AVG) on the film cooling performance of a circular cooling hole which has diameter (d = 20 mm) on a flat plate. The interaction between the jet cooling air and mainstream will result kidney vortex which will eliminate the film cooling effectiveness. Two types of AVG with different heights (H = 0.5 d and 0.25 d) are designed to eliminate the kidney vortex and investigate best film cooling effectiveness, where each of them is mounted to the flat plate upstream of the cooling hole by changing its lateral positions (A = 0.0 d, 0.25 d, 0.5 d and 0.75 d) with respect to the hole centerline and for each type has different distance respect to hole centerline. The changing of blowing ratio (BR = 0.5-1.5) was considered in this study. As for the validation, the present study was compared with the previous research done by other researchers using the results obtained from experimental data. The steady turbulence model shear stress transport (SST) that was used to simulate a film cooling configuration. The results have been presented in terms of laterally averaged film cooling comparison graphs, velocity field on x/d = 3.0, non-dimensional temperature on x/d = 3.0 and the vorticity on x/d = 3.0 which explained how the results obtained. Cases 04 and 07 gave the best positions for AVG where case 04 gave wide covered for laterally average film cooling effectiveness , while case 07 gave the highest expand distribution and the maximum value for film cooling effectiveness .
format Thesis
author Abu Zarida, Abdallah Ali
author_facet Abu Zarida, Abdallah Ali
author_sort Abu Zarida, Abdallah Ali
title Investigation of film cooling effectiveness from cylindrical cooling hole with anti vortex generator by numerical simulation
title_short Investigation of film cooling effectiveness from cylindrical cooling hole with anti vortex generator by numerical simulation
title_full Investigation of film cooling effectiveness from cylindrical cooling hole with anti vortex generator by numerical simulation
title_fullStr Investigation of film cooling effectiveness from cylindrical cooling hole with anti vortex generator by numerical simulation
title_full_unstemmed Investigation of film cooling effectiveness from cylindrical cooling hole with anti vortex generator by numerical simulation
title_sort investigation of film cooling effectiveness from cylindrical cooling hole with anti vortex generator by numerical simulation
publishDate 2015
url http://eprints.uthm.edu.my/1246/2/ABDALLAH%20ALI%20ABU%20ZARIDA%20COPYRIGHT%20DECLARATION.pdf
http://eprints.uthm.edu.my/1246/1/24p%20ABDALLAH%20ALI%20ABU%20ZARIDA.pdf
http://eprints.uthm.edu.my/1246/3/ABDALLAH%20ALI%20ABU%20ZARIDA%20WATERMARK.pdf
http://eprints.uthm.edu.my/1246/
_version_ 1738580837830492160
score 13.159267