Analysis of Switchgear on Insulation Performance and Reliability in Malaysian Railway Double Track Project

Switchgears are the key component in protecting equipment in High Voltage (HV) settings. With the rise of railway projects in Malaysia, there will be an increase in demand for switchgear for the electrification project. Therefore, the type of switchgear that is better in terms of insulation performa...

Full description

Saved in:
Bibliographic Details
Main Authors: Sahari, Norain, Ngadiron, Zuraidah, Zulkifli, Dinie Amani, Ganasan, Reventheran, Ismail, Noramin, Kamaluddin, N.A.
Format: Article
Language:English
Published: 2023
Subjects:
Online Access:http://eprints.uthm.edu.my/11555/1/J16083_0e24af623f73dece81bba1031da0cfa1.pdf
http://eprints.uthm.edu.my/11555/
https://doi.org/10.14445/22315381/IJETT-V71I4P207
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.11555
record_format eprints
spelling my.uthm.eprints.115552024-09-03T08:48:53Z http://eprints.uthm.edu.my/11555/ Analysis of Switchgear on Insulation Performance and Reliability in Malaysian Railway Double Track Project Sahari, Norain Ngadiron, Zuraidah Zulkifli, Dinie Amani Ganasan, Reventheran Ismail, Noramin Kamaluddin, N.A. T Technology (General) Switchgears are the key component in protecting equipment in High Voltage (HV) settings. With the rise of railway projects in Malaysia, there will be an increase in demand for switchgear for the electrification project. Therefore, the type of switchgear that is better in terms of insulation performance and reliability needs to be determined. Then, a simulation model is developed in order to measure the Partial Discharge (PD) in the insulation medium of the switchgears. An analysis is conducted in order to compare which insulation medium is superior for switchgear. It is found that Sulfur-Hexafluoride (SF6) gas is seen to have lower values of peak voltage during PD inside the insulation medium compared to air. SF6 gas proves to be the better insulation medium compared to air in terms of insulation performance and reliability due to the lower values of peak voltage detected during the occurrence of PD. The finding of insulation performances will enhance the quality of Malaysian railways in order to decrease the breakdowns and disturbances related to the electrification system. 2023 Article PeerReviewed text en http://eprints.uthm.edu.my/11555/1/J16083_0e24af623f73dece81bba1031da0cfa1.pdf Sahari, Norain and Ngadiron, Zuraidah and Zulkifli, Dinie Amani and Ganasan, Reventheran and Ismail, Noramin and Kamaluddin, N.A. (2023) Analysis of Switchgear on Insulation Performance and Reliability in Malaysian Railway Double Track Project. International Journal of Engineering Trends and Technology, 71 (4). pp. 72-78. ISSN 2231–5381 / https://doi.org/10.14445/22315381/IJETT-V71I4P207
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
topic T Technology (General)
spellingShingle T Technology (General)
Sahari, Norain
Ngadiron, Zuraidah
Zulkifli, Dinie Amani
Ganasan, Reventheran
Ismail, Noramin
Kamaluddin, N.A.
Analysis of Switchgear on Insulation Performance and Reliability in Malaysian Railway Double Track Project
description Switchgears are the key component in protecting equipment in High Voltage (HV) settings. With the rise of railway projects in Malaysia, there will be an increase in demand for switchgear for the electrification project. Therefore, the type of switchgear that is better in terms of insulation performance and reliability needs to be determined. Then, a simulation model is developed in order to measure the Partial Discharge (PD) in the insulation medium of the switchgears. An analysis is conducted in order to compare which insulation medium is superior for switchgear. It is found that Sulfur-Hexafluoride (SF6) gas is seen to have lower values of peak voltage during PD inside the insulation medium compared to air. SF6 gas proves to be the better insulation medium compared to air in terms of insulation performance and reliability due to the lower values of peak voltage detected during the occurrence of PD. The finding of insulation performances will enhance the quality of Malaysian railways in order to decrease the breakdowns and disturbances related to the electrification system.
format Article
author Sahari, Norain
Ngadiron, Zuraidah
Zulkifli, Dinie Amani
Ganasan, Reventheran
Ismail, Noramin
Kamaluddin, N.A.
author_facet Sahari, Norain
Ngadiron, Zuraidah
Zulkifli, Dinie Amani
Ganasan, Reventheran
Ismail, Noramin
Kamaluddin, N.A.
author_sort Sahari, Norain
title Analysis of Switchgear on Insulation Performance and Reliability in Malaysian Railway Double Track Project
title_short Analysis of Switchgear on Insulation Performance and Reliability in Malaysian Railway Double Track Project
title_full Analysis of Switchgear on Insulation Performance and Reliability in Malaysian Railway Double Track Project
title_fullStr Analysis of Switchgear on Insulation Performance and Reliability in Malaysian Railway Double Track Project
title_full_unstemmed Analysis of Switchgear on Insulation Performance and Reliability in Malaysian Railway Double Track Project
title_sort analysis of switchgear on insulation performance and reliability in malaysian railway double track project
publishDate 2023
url http://eprints.uthm.edu.my/11555/1/J16083_0e24af623f73dece81bba1031da0cfa1.pdf
http://eprints.uthm.edu.my/11555/
https://doi.org/10.14445/22315381/IJETT-V71I4P207
_version_ 1811687198822498304
score 13.214268