Modelling a D-shaped Sensor for Transformer Oil Refractive Index Detection

A simulative-based investigation using COMSOL Multiphysics software has been carried out to study the sensing performance of a D-shaped refractive index (RI) sensor in the ageing detection of transformer oil. In this work, a D-shaped plastic optical fiber (POF) RI sensor has been modelled to have a...

Full description

Saved in:
Bibliographic Details
Main Authors: Md Yasin, Muhammad Zakir, Ngajikin, Nor Hafizah, Aminah Ali, Siti Hajar, Abdul Kadar, Muhammad Sazlan, Che Abd Rashid, Nurfatihah, Talib, Mohd Aizam, Cholan, Noran Azizan
Format: Article
Language:English
Published: semarak ilmu 2024
Subjects:
Online Access:http://eprints.uthm.edu.my/11081/1/J17567_a424b0917fef993806f53117157b4533.pdf
http://eprints.uthm.edu.my/11081/
https://doi.org/10.37934/aram.114.1.4350
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.11081
record_format eprints
spelling my.uthm.eprints.110812024-06-04T03:04:56Z http://eprints.uthm.edu.my/11081/ Modelling a D-shaped Sensor for Transformer Oil Refractive Index Detection Md Yasin, Muhammad Zakir Ngajikin, Nor Hafizah Aminah Ali, Siti Hajar Abdul Kadar, Muhammad Sazlan Che Abd Rashid, Nurfatihah Talib, Mohd Aizam Cholan, Noran Azizan T Technology (General) A simulative-based investigation using COMSOL Multiphysics software has been carried out to study the sensing performance of a D-shaped refractive index (RI) sensor in the ageing detection of transformer oil. In this work, a D-shaped plastic optical fiber (POF) RI sensor has been modelled to have a curve surface for its D region. This surface that exposed some parts of the POF core and cladding, enables interaction between the transformer oil located in the D region with optical light propagate in the POF. The simulation has been conducted to study the effect of D region diameter towards the sensor electric field distribution, sensitivity and linearity performances. The transformer oil RI value is ranging from 1.4785 to 1.4807, which is based on the transformer oil samples provided by the TNB Labs Sdn Bhd. The RI variations affect the evanescent wave's penetration depth, thus varying the electric field distribution in the sensor. In this investigation, the 0.75cm diameter of the D-shaped POF RI sensor exhibits the highest sensitivity of -0.1426 RIU-1 with a linearity of 0.9998 at 660nm wavelength. The proposed D-shaped RI sensor offers a sensor with high linearity performance sensor to be applied in transformer oil ageing detection. semarak ilmu 2024 Article PeerReviewed text en http://eprints.uthm.edu.my/11081/1/J17567_a424b0917fef993806f53117157b4533.pdf Md Yasin, Muhammad Zakir and Ngajikin, Nor Hafizah and Aminah Ali, Siti Hajar and Abdul Kadar, Muhammad Sazlan and Che Abd Rashid, Nurfatihah and Talib, Mohd Aizam and Cholan, Noran Azizan (2024) Modelling a D-shaped Sensor for Transformer Oil Refractive Index Detection. Journal of Advanced Research in Applied Mechanics, 114 (1). pp. 43-50. ISSN 2289-7895 https://doi.org/10.37934/aram.114.1.4350
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
topic T Technology (General)
spellingShingle T Technology (General)
Md Yasin, Muhammad Zakir
Ngajikin, Nor Hafizah
Aminah Ali, Siti Hajar
Abdul Kadar, Muhammad Sazlan
Che Abd Rashid, Nurfatihah
Talib, Mohd Aizam
Cholan, Noran Azizan
Modelling a D-shaped Sensor for Transformer Oil Refractive Index Detection
description A simulative-based investigation using COMSOL Multiphysics software has been carried out to study the sensing performance of a D-shaped refractive index (RI) sensor in the ageing detection of transformer oil. In this work, a D-shaped plastic optical fiber (POF) RI sensor has been modelled to have a curve surface for its D region. This surface that exposed some parts of the POF core and cladding, enables interaction between the transformer oil located in the D region with optical light propagate in the POF. The simulation has been conducted to study the effect of D region diameter towards the sensor electric field distribution, sensitivity and linearity performances. The transformer oil RI value is ranging from 1.4785 to 1.4807, which is based on the transformer oil samples provided by the TNB Labs Sdn Bhd. The RI variations affect the evanescent wave's penetration depth, thus varying the electric field distribution in the sensor. In this investigation, the 0.75cm diameter of the D-shaped POF RI sensor exhibits the highest sensitivity of -0.1426 RIU-1 with a linearity of 0.9998 at 660nm wavelength. The proposed D-shaped RI sensor offers a sensor with high linearity performance sensor to be applied in transformer oil ageing detection.
format Article
author Md Yasin, Muhammad Zakir
Ngajikin, Nor Hafizah
Aminah Ali, Siti Hajar
Abdul Kadar, Muhammad Sazlan
Che Abd Rashid, Nurfatihah
Talib, Mohd Aizam
Cholan, Noran Azizan
author_facet Md Yasin, Muhammad Zakir
Ngajikin, Nor Hafizah
Aminah Ali, Siti Hajar
Abdul Kadar, Muhammad Sazlan
Che Abd Rashid, Nurfatihah
Talib, Mohd Aizam
Cholan, Noran Azizan
author_sort Md Yasin, Muhammad Zakir
title Modelling a D-shaped Sensor for Transformer Oil Refractive Index Detection
title_short Modelling a D-shaped Sensor for Transformer Oil Refractive Index Detection
title_full Modelling a D-shaped Sensor for Transformer Oil Refractive Index Detection
title_fullStr Modelling a D-shaped Sensor for Transformer Oil Refractive Index Detection
title_full_unstemmed Modelling a D-shaped Sensor for Transformer Oil Refractive Index Detection
title_sort modelling a d-shaped sensor for transformer oil refractive index detection
publisher semarak ilmu
publishDate 2024
url http://eprints.uthm.edu.my/11081/1/J17567_a424b0917fef993806f53117157b4533.pdf
http://eprints.uthm.edu.my/11081/
https://doi.org/10.37934/aram.114.1.4350
_version_ 1803337334400221184
score 13.160551