MODELLING OF CO-AXIAL AND TRI-AXIAL MILLIFLUIDIC DEVICES FOR CO-EXTRUSION OF SEMI-SOLID SOLIDS

With the use of a milli-fluidics device, it is possible to manipulate small amounts of fluid in the millimeter range with pinpoint accuracy. The millifluidics are currently lacking in studies of the relationship between fluid viscosity, output velocity and output pressure. Thus, this study examines...

Full description

Saved in:
Bibliographic Details
Main Authors: Abdo Ali Al-Sharai, Abdo Ali Al-Sharai, Chin Fhong Soon, Chin Fhong Soon, Chan Hwang See, Chan Hwang See, See Khee Yee, See Khee Yee, Kian Sek Tee, Kian Sek Tee, Mohammed Abdul Wahab, Mohammed Abdul Wahab
Format: Article
Language:English
Published: UTM 2023
Subjects:
Online Access:http://eprints.uthm.edu.my/10510/1/J16127_bc966f4f361dddd2691758dfdf81cc77.pdf
http://eprints.uthm.edu.my/10510/
https://doi.org/10.11113/aej.V13.18953
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.uthm.eprints.10510
record_format eprints
spelling my.uthm.eprints.105102023-11-27T07:27:03Z http://eprints.uthm.edu.my/10510/ MODELLING OF CO-AXIAL AND TRI-AXIAL MILLIFLUIDIC DEVICES FOR CO-EXTRUSION OF SEMI-SOLID SOLIDS Abdo Ali Al-Sharai, Abdo Ali Al-Sharai Chin Fhong Soon, Chin Fhong Soon Chan Hwang See, Chan Hwang See See Khee Yee, See Khee Yee Kian Sek Tee, Kian Sek Tee Mohammed Abdul Wahab, Mohammed Abdul Wahab T Technology (General) With the use of a milli-fluidics device, it is possible to manipulate small amounts of fluid in the millimeter range with pinpoint accuracy. The millifluidics are currently lacking in studies of the relationship between fluid viscosity, output velocity and output pressure. Thus, this study examines the effects of viscosity on fluid dynamics in the co-axial and tri-axial milli-fluidics. This geometry of the co-axial and tri-axial milli-fluidics consist of single outlet, two inlets and three inlets, respectively. The tri-axial milli-fluidics is 46 mm long and 11.31 mm wide, while, the coaxial milli-fluidic is 64.73 mm long and 9.2 mm wide. The co-axial milli-fluidics constituted of 775 domain elements and 147 boundary elements, while, the tri-axial milli-fluidics mesh constituted of 1518 domain elements and 178 boundary elements. Laminar flow was observed for the flow of the materials through the channels. When the dynamic viscosity approaches 5 mPa.s, the simulation reveals that the flow rate is inversely proportional to the dynamic viscosity for co-axial millifluidics. It was difficult to combine fluids with different viscosities with small volume of water in a narrow boundary, thus the parallel flow of material was observed. When using the one outlet channel for the tri-axial milli-fluidics, the assemble pressure at the three inlets was decreased compared with coaxial milli-fluidic. Even when the dynamic velocity of the fluid at outlet 1 increased, its velocity remained consistent. An extruder using tri-axial millifluidics can be used if the interfacial tension for intake 1 is higher than for inlet 2 and the dynamic viscosity of fluid 1 is above 2 mPas, according to the volumetric fraction model. The tri-axial milli-fluidic was found to be suitable for producing cladding of material with the balanced pressure from the two side channels. Keywords: Co-axial UTM 2023 Article PeerReviewed text en http://eprints.uthm.edu.my/10510/1/J16127_bc966f4f361dddd2691758dfdf81cc77.pdf Abdo Ali Al-Sharai, Abdo Ali Al-Sharai and Chin Fhong Soon, Chin Fhong Soon and Chan Hwang See, Chan Hwang See and See Khee Yee, See Khee Yee and Kian Sek Tee, Kian Sek Tee and Mohammed Abdul Wahab, Mohammed Abdul Wahab (2023) MODELLING OF CO-AXIAL AND TRI-AXIAL MILLIFLUIDIC DEVICES FOR CO-EXTRUSION OF SEMI-SOLID SOLIDS. ASEAN Engineering Journal, 13 (2). pp. 93-100. ISSN 2586–9159 https://doi.org/10.11113/aej.V13.18953
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
topic T Technology (General)
spellingShingle T Technology (General)
Abdo Ali Al-Sharai, Abdo Ali Al-Sharai
Chin Fhong Soon, Chin Fhong Soon
Chan Hwang See, Chan Hwang See
See Khee Yee, See Khee Yee
Kian Sek Tee, Kian Sek Tee
Mohammed Abdul Wahab, Mohammed Abdul Wahab
MODELLING OF CO-AXIAL AND TRI-AXIAL MILLIFLUIDIC DEVICES FOR CO-EXTRUSION OF SEMI-SOLID SOLIDS
description With the use of a milli-fluidics device, it is possible to manipulate small amounts of fluid in the millimeter range with pinpoint accuracy. The millifluidics are currently lacking in studies of the relationship between fluid viscosity, output velocity and output pressure. Thus, this study examines the effects of viscosity on fluid dynamics in the co-axial and tri-axial milli-fluidics. This geometry of the co-axial and tri-axial milli-fluidics consist of single outlet, two inlets and three inlets, respectively. The tri-axial milli-fluidics is 46 mm long and 11.31 mm wide, while, the coaxial milli-fluidic is 64.73 mm long and 9.2 mm wide. The co-axial milli-fluidics constituted of 775 domain elements and 147 boundary elements, while, the tri-axial milli-fluidics mesh constituted of 1518 domain elements and 178 boundary elements. Laminar flow was observed for the flow of the materials through the channels. When the dynamic viscosity approaches 5 mPa.s, the simulation reveals that the flow rate is inversely proportional to the dynamic viscosity for co-axial millifluidics. It was difficult to combine fluids with different viscosities with small volume of water in a narrow boundary, thus the parallel flow of material was observed. When using the one outlet channel for the tri-axial milli-fluidics, the assemble pressure at the three inlets was decreased compared with coaxial milli-fluidic. Even when the dynamic velocity of the fluid at outlet 1 increased, its velocity remained consistent. An extruder using tri-axial millifluidics can be used if the interfacial tension for intake 1 is higher than for inlet 2 and the dynamic viscosity of fluid 1 is above 2 mPas, according to the volumetric fraction model. The tri-axial milli-fluidic was found to be suitable for producing cladding of material with the balanced pressure from the two side channels. Keywords: Co-axial
format Article
author Abdo Ali Al-Sharai, Abdo Ali Al-Sharai
Chin Fhong Soon, Chin Fhong Soon
Chan Hwang See, Chan Hwang See
See Khee Yee, See Khee Yee
Kian Sek Tee, Kian Sek Tee
Mohammed Abdul Wahab, Mohammed Abdul Wahab
author_facet Abdo Ali Al-Sharai, Abdo Ali Al-Sharai
Chin Fhong Soon, Chin Fhong Soon
Chan Hwang See, Chan Hwang See
See Khee Yee, See Khee Yee
Kian Sek Tee, Kian Sek Tee
Mohammed Abdul Wahab, Mohammed Abdul Wahab
author_sort Abdo Ali Al-Sharai, Abdo Ali Al-Sharai
title MODELLING OF CO-AXIAL AND TRI-AXIAL MILLIFLUIDIC DEVICES FOR CO-EXTRUSION OF SEMI-SOLID SOLIDS
title_short MODELLING OF CO-AXIAL AND TRI-AXIAL MILLIFLUIDIC DEVICES FOR CO-EXTRUSION OF SEMI-SOLID SOLIDS
title_full MODELLING OF CO-AXIAL AND TRI-AXIAL MILLIFLUIDIC DEVICES FOR CO-EXTRUSION OF SEMI-SOLID SOLIDS
title_fullStr MODELLING OF CO-AXIAL AND TRI-AXIAL MILLIFLUIDIC DEVICES FOR CO-EXTRUSION OF SEMI-SOLID SOLIDS
title_full_unstemmed MODELLING OF CO-AXIAL AND TRI-AXIAL MILLIFLUIDIC DEVICES FOR CO-EXTRUSION OF SEMI-SOLID SOLIDS
title_sort modelling of co-axial and tri-axial millifluidic devices for co-extrusion of semi-solid solids
publisher UTM
publishDate 2023
url http://eprints.uthm.edu.my/10510/1/J16127_bc966f4f361dddd2691758dfdf81cc77.pdf
http://eprints.uthm.edu.my/10510/
https://doi.org/10.11113/aej.V13.18953
_version_ 1783880449630666752
score 13.214268