Analysis of a Squeezing Flow of a Casson Nanofluid between Two Parallel Disks in the Presence of a Variable Magnetic Field
The present article deals with the MHD flow of a Casson nanofluid between two disks. The lower disk was fixed as well as permeable. The upper disk was not permeable, but it could move perpendicularly up and down toward the lower disk. Titanium dioxide was selected as nanoparticles and water as a bas...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Mdpi
2023
|
Subjects: | |
Online Access: | http://eprints.uthm.edu.my/10199/1/J15667_7fff632405a4ee48703740a63b1907a6.pdf http://eprints.uthm.edu.my/10199/ https://doi.org/10.3390/sym15010120 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.uthm.eprints.10199 |
---|---|
record_format |
eprints |
spelling |
my.uthm.eprints.101992023-10-18T02:35:40Z http://eprints.uthm.edu.my/10199/ Analysis of a Squeezing Flow of a Casson Nanofluid between Two Parallel Disks in the Presence of a Variable Magnetic Field Reshu Gupta, Reshu Gupta Janani Selvam, Janani Selvam Ashok Vajravelu, Ashok Vajravelu Sasitharan Nagapan, Sasitharan Nagapan T Technology (General) The present article deals with the MHD flow of a Casson nanofluid between two disks. The lower disk was fixed as well as permeable. The upper disk was not permeable, but it could move perpendicularly up and down toward the lower disk. Titanium dioxide was selected as nanoparticles and water as a base fluid. The governing higher-order nonlinear partial differential equations were transformed into a set of nonlinear ordinary differential equations by using similarity transformation. The differential transform method (DTM) was applied to solve the nonlinear ODEs. The nature of the velocity profiles for the different values of the suction injection parameter, the squeeze number, the Casson fluid parameter, and the volume fraction parameter of the nanofluid are pictorially discussed in this paper. The coefficient of skin friction was tabulated for the novelty of the research. The comparison of the results was determined by the DTM and the numerical methods. The profile values were also compared with the literature work and found to agree. This comparative study proves the accuracy and efficiency of the method. It is concluded from this research that the flow properties behave oppositely for all parameters during suction and injection. Mdpi 2023 Article PeerReviewed text en http://eprints.uthm.edu.my/10199/1/J15667_7fff632405a4ee48703740a63b1907a6.pdf Reshu Gupta, Reshu Gupta and Janani Selvam, Janani Selvam and Ashok Vajravelu, Ashok Vajravelu and Sasitharan Nagapan, Sasitharan Nagapan (2023) Analysis of a Squeezing Flow of a Casson Nanofluid between Two Parallel Disks in the Presence of a Variable Magnetic Field. Symmetry, 15 (120). pp. 1-17. https://doi.org/10.3390/sym15010120 |
institution |
Universiti Tun Hussein Onn Malaysia |
building |
UTHM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tun Hussein Onn Malaysia |
content_source |
UTHM Institutional Repository |
url_provider |
http://eprints.uthm.edu.my/ |
language |
English |
topic |
T Technology (General) |
spellingShingle |
T Technology (General) Reshu Gupta, Reshu Gupta Janani Selvam, Janani Selvam Ashok Vajravelu, Ashok Vajravelu Sasitharan Nagapan, Sasitharan Nagapan Analysis of a Squeezing Flow of a Casson Nanofluid between Two Parallel Disks in the Presence of a Variable Magnetic Field |
description |
The present article deals with the MHD flow of a Casson nanofluid between two disks. The lower disk was fixed as well as permeable. The upper disk was not permeable, but it could move perpendicularly up and down toward the lower disk. Titanium dioxide was selected as nanoparticles and water as a base fluid. The governing higher-order nonlinear partial differential equations were transformed into a set of nonlinear ordinary differential equations by using similarity
transformation. The differential transform method (DTM) was applied to solve the nonlinear ODEs. The nature of the velocity profiles for the different values of the suction injection parameter, the squeeze number, the Casson fluid parameter, and the volume fraction parameter of the nanofluid are pictorially discussed in this paper. The coefficient of skin friction was tabulated for the novelty
of the research. The comparison of the results was determined by the DTM and the numerical methods. The profile values were also compared with the literature work and found to agree. This comparative study proves the accuracy and efficiency of the method. It is concluded from this research that the flow properties behave oppositely for all parameters during suction and injection. |
format |
Article |
author |
Reshu Gupta, Reshu Gupta Janani Selvam, Janani Selvam Ashok Vajravelu, Ashok Vajravelu Sasitharan Nagapan, Sasitharan Nagapan |
author_facet |
Reshu Gupta, Reshu Gupta Janani Selvam, Janani Selvam Ashok Vajravelu, Ashok Vajravelu Sasitharan Nagapan, Sasitharan Nagapan |
author_sort |
Reshu Gupta, Reshu Gupta |
title |
Analysis of a Squeezing Flow of a Casson Nanofluid between
Two Parallel Disks in the Presence of a Variable Magnetic Field |
title_short |
Analysis of a Squeezing Flow of a Casson Nanofluid between
Two Parallel Disks in the Presence of a Variable Magnetic Field |
title_full |
Analysis of a Squeezing Flow of a Casson Nanofluid between
Two Parallel Disks in the Presence of a Variable Magnetic Field |
title_fullStr |
Analysis of a Squeezing Flow of a Casson Nanofluid between
Two Parallel Disks in the Presence of a Variable Magnetic Field |
title_full_unstemmed |
Analysis of a Squeezing Flow of a Casson Nanofluid between
Two Parallel Disks in the Presence of a Variable Magnetic Field |
title_sort |
analysis of a squeezing flow of a casson nanofluid between
two parallel disks in the presence of a variable magnetic field |
publisher |
Mdpi |
publishDate |
2023 |
url |
http://eprints.uthm.edu.my/10199/1/J15667_7fff632405a4ee48703740a63b1907a6.pdf http://eprints.uthm.edu.my/10199/ https://doi.org/10.3390/sym15010120 |
_version_ |
1781707448440061952 |
score |
13.214268 |