Optimal operation of chillers plant in academic building by using linear programming approach
The operation of chillers plant in the HVAC system is not ideally efficient in major academic buildings because the chillers are operated without accounting for the cooling load demand of the air-conditioning area of the building. The current operation of the chillers plant may fall under two coolin...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
The Italian Association of Chemical Engineering - AIDIC
2022
|
Online Access: | http://eprints.utem.edu.my/id/eprint/26702/2/CET%202022%20-%20OPTIMAL%20OPERATION%20OF%20CHILLERS%20PLANT%20IN%20ACADEMIC%20BUILDING%20BY%20USING%20LINEAR%20PROGRAMMING%20APPROACH.PDF http://eprints.utem.edu.my/id/eprint/26702/ https://www.cetjournal.it/cet/22/97/016.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utem.eprints.26702 |
---|---|
record_format |
eprints |
spelling |
my.utem.eprints.267022023-03-28T10:37:09Z http://eprints.utem.edu.my/id/eprint/26702/ Optimal operation of chillers plant in academic building by using linear programming approach Zulkafli, Nur Izyan Sukri, Mohamad Firdaus Mohd Tahir, Musthafah Muhajir, Asjufri Hanak, Dawid Piotr The operation of chillers plant in the HVAC system is not ideally efficient in major academic buildings because the chillers are operated without accounting for the cooling load demand of the air-conditioning area of the building. The current operation of the chillers plant may fall under two cooling effects, namely excessive cooling effect that will reduce the efficiency of the chillers and inadequate cooling effect that may create an unpleasant environment inside the air-conditioning area. This is because the cooling load demand of the air-conditioning area of the building is unknown and is not numerically measured. The main aim of this study is to find the optimal operation of chillers plant in HVAC system by formulating an optimization framework with the main goal of minimizing energy consumption and electricity costs. The formulation of the optimization framework for chillers plant operation is modelled as Linear Programming (LP) to establish real representation of the chillers plant. The energy consumption profile, cooling load demand, cooling capacity and COP can be obtained by using historical data analysis. The optimization framework is modelled in GAMS v38.2.1 and solved by CPLEX solver to obtain the optimum input for the chillers plant in the HVAC system. The minimum total power consumption can be achieved by optimally coordinating the operation of chillers, cooling towers and AHUs while maintaining room temperature. From the cost comparison analysis between the current and optimal chillers plant, considerable cost reduction is expected to be less than 5 % if the chillers plant is operating efficiently or greater than 30 % if the chillers plant is not functioning effectively. Therefore, this study is beneficial to the administration of academic building to find a strategic action plan to promote cost optimization in the operation of the chillers plant. The Italian Association of Chemical Engineering - AIDIC 2022-09-01 Article PeerReviewed text en http://eprints.utem.edu.my/id/eprint/26702/2/CET%202022%20-%20OPTIMAL%20OPERATION%20OF%20CHILLERS%20PLANT%20IN%20ACADEMIC%20BUILDING%20BY%20USING%20LINEAR%20PROGRAMMING%20APPROACH.PDF Zulkafli, Nur Izyan and Sukri, Mohamad Firdaus and Mohd Tahir, Musthafah and Muhajir, Asjufri and Hanak, Dawid Piotr (2022) Optimal operation of chillers plant in academic building by using linear programming approach. Chemical Engineering Transactions, 97. pp. 91-96. ISSN 2283-9216 https://www.cetjournal.it/cet/22/97/016.pdf 10.3303/CET2297016 |
institution |
Universiti Teknikal Malaysia Melaka |
building |
UTEM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknikal Malaysia Melaka |
content_source |
UTEM Institutional Repository |
url_provider |
http://eprints.utem.edu.my/ |
language |
English |
description |
The operation of chillers plant in the HVAC system is not ideally efficient in major academic buildings because the chillers are operated without accounting for the cooling load demand of the air-conditioning area of the building. The current operation of the chillers plant may fall under two cooling effects, namely excessive cooling effect that will reduce the efficiency of the chillers and inadequate cooling effect that may create an unpleasant environment inside the air-conditioning area. This is because the cooling load demand of the air-conditioning area of the building is unknown and is not numerically measured. The main aim of this study is to find the optimal operation of chillers plant in HVAC system by formulating an optimization framework with the main goal of minimizing energy consumption and electricity costs. The formulation of the optimization framework for chillers plant operation is modelled as Linear Programming (LP) to establish real representation of the chillers plant. The energy consumption profile, cooling load demand, cooling capacity and COP can be obtained by using historical data analysis. The optimization framework is modelled in GAMS v38.2.1 and solved by CPLEX solver to obtain the optimum input for the chillers plant in the HVAC system. The minimum total power consumption can be achieved by optimally coordinating the operation of chillers, cooling towers and AHUs while maintaining room temperature. From the cost comparison analysis between the current and optimal chillers plant, considerable cost reduction is expected to be less than 5 % if the chillers plant is operating efficiently or greater than 30 % if the chillers plant is not functioning effectively. Therefore, this study is beneficial to the administration of academic building to find a strategic action plan to promote cost optimization in the operation of the chillers plant. |
format |
Article |
author |
Zulkafli, Nur Izyan Sukri, Mohamad Firdaus Mohd Tahir, Musthafah Muhajir, Asjufri Hanak, Dawid Piotr |
spellingShingle |
Zulkafli, Nur Izyan Sukri, Mohamad Firdaus Mohd Tahir, Musthafah Muhajir, Asjufri Hanak, Dawid Piotr Optimal operation of chillers plant in academic building by using linear programming approach |
author_facet |
Zulkafli, Nur Izyan Sukri, Mohamad Firdaus Mohd Tahir, Musthafah Muhajir, Asjufri Hanak, Dawid Piotr |
author_sort |
Zulkafli, Nur Izyan |
title |
Optimal operation of chillers plant in academic building by using linear programming approach |
title_short |
Optimal operation of chillers plant in academic building by using linear programming approach |
title_full |
Optimal operation of chillers plant in academic building by using linear programming approach |
title_fullStr |
Optimal operation of chillers plant in academic building by using linear programming approach |
title_full_unstemmed |
Optimal operation of chillers plant in academic building by using linear programming approach |
title_sort |
optimal operation of chillers plant in academic building by using linear programming approach |
publisher |
The Italian Association of Chemical Engineering - AIDIC |
publishDate |
2022 |
url |
http://eprints.utem.edu.my/id/eprint/26702/2/CET%202022%20-%20OPTIMAL%20OPERATION%20OF%20CHILLERS%20PLANT%20IN%20ACADEMIC%20BUILDING%20BY%20USING%20LINEAR%20PROGRAMMING%20APPROACH.PDF http://eprints.utem.edu.my/id/eprint/26702/ https://www.cetjournal.it/cet/22/97/016.pdf |
_version_ |
1761623121058594816 |
score |
13.211869 |