Comparative study of electrical test methods on detecting transformer faults

Condition monitoring of distribution and power transformers is of utmost importance to utilities due to cost effectiveness concerns. The common faults that occur in transformers are short circuits and winding deformation. To date, there are many established test methods used to detect these faults....

Full description

Saved in:
Bibliographic Details
Main Authors: Ab Ghani, Sharin, Ahmad Khiar, Mohd Shahril, Rahim, Nor Hidayah, Sutan Chairul, Imran, Kamaruzaini, Mohd Hisamuddin
Format: Article
Language:English
Published: Institute Of Advanced Engineering And Science (IAES) 2022
Online Access:http://eprints.utem.edu.my/id/eprint/26329/2/26931-51963-1-PB.PDF
http://eprints.utem.edu.my/id/eprint/26329/
https://ijeecs.iaescore.com/index.php/IJEECS/article/view/26931/15987
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utem.eprints.26329
record_format eprints
spelling my.utem.eprints.263292023-03-06T12:34:27Z http://eprints.utem.edu.my/id/eprint/26329/ Comparative study of electrical test methods on detecting transformer faults Ab Ghani, Sharin Ahmad Khiar, Mohd Shahril Rahim, Nor Hidayah Sutan Chairul, Imran Kamaruzaini, Mohd Hisamuddin Condition monitoring of distribution and power transformers is of utmost importance to utilities due to cost effectiveness concerns. The common faults that occur in transformers are short circuits and winding deformation. To date, there are many established test methods used to detect these faults. In this study, three test methods (insulation resistance (IR), transformer turn ratio (TTR), and frequency response analysis (FRA)) were compared to assess their effectiveness in detecting short circuit and winding deformation in a three-phase transformer. Based on the results, the three test methods were found to be capable of detecting short circuits. However, only TTR and FRA can detect winding deformation, and FRA can further indicate which phase is faulty. Therefore, it is concluded that FRA is more effective in detecting short circuit and winding deformation of a three-phase transformer. Institute Of Advanced Engineering And Science (IAES) 2022 Article PeerReviewed text en http://eprints.utem.edu.my/id/eprint/26329/2/26931-51963-1-PB.PDF Ab Ghani, Sharin and Ahmad Khiar, Mohd Shahril and Rahim, Nor Hidayah and Sutan Chairul, Imran and Kamaruzaini, Mohd Hisamuddin (2022) Comparative study of electrical test methods on detecting transformer faults. Indonesian Journal Of Electrical Engineering And Computer Science, 25 (2). pp. 755-762. ISSN 2502-4752 https://ijeecs.iaescore.com/index.php/IJEECS/article/view/26931/15987 10.11591/ijeecs.v25.i2.pp755-762
institution Universiti Teknikal Malaysia Melaka
building UTEM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknikal Malaysia Melaka
content_source UTEM Institutional Repository
url_provider http://eprints.utem.edu.my/
language English
description Condition monitoring of distribution and power transformers is of utmost importance to utilities due to cost effectiveness concerns. The common faults that occur in transformers are short circuits and winding deformation. To date, there are many established test methods used to detect these faults. In this study, three test methods (insulation resistance (IR), transformer turn ratio (TTR), and frequency response analysis (FRA)) were compared to assess their effectiveness in detecting short circuit and winding deformation in a three-phase transformer. Based on the results, the three test methods were found to be capable of detecting short circuits. However, only TTR and FRA can detect winding deformation, and FRA can further indicate which phase is faulty. Therefore, it is concluded that FRA is more effective in detecting short circuit and winding deformation of a three-phase transformer.
format Article
author Ab Ghani, Sharin
Ahmad Khiar, Mohd Shahril
Rahim, Nor Hidayah
Sutan Chairul, Imran
Kamaruzaini, Mohd Hisamuddin
spellingShingle Ab Ghani, Sharin
Ahmad Khiar, Mohd Shahril
Rahim, Nor Hidayah
Sutan Chairul, Imran
Kamaruzaini, Mohd Hisamuddin
Comparative study of electrical test methods on detecting transformer faults
author_facet Ab Ghani, Sharin
Ahmad Khiar, Mohd Shahril
Rahim, Nor Hidayah
Sutan Chairul, Imran
Kamaruzaini, Mohd Hisamuddin
author_sort Ab Ghani, Sharin
title Comparative study of electrical test methods on detecting transformer faults
title_short Comparative study of electrical test methods on detecting transformer faults
title_full Comparative study of electrical test methods on detecting transformer faults
title_fullStr Comparative study of electrical test methods on detecting transformer faults
title_full_unstemmed Comparative study of electrical test methods on detecting transformer faults
title_sort comparative study of electrical test methods on detecting transformer faults
publisher Institute Of Advanced Engineering And Science (IAES)
publishDate 2022
url http://eprints.utem.edu.my/id/eprint/26329/2/26931-51963-1-PB.PDF
http://eprints.utem.edu.my/id/eprint/26329/
https://ijeecs.iaescore.com/index.php/IJEECS/article/view/26931/15987
_version_ 1759693066073014272
score 13.160551