Achieving Energy Cost Saving Using Best Energy Tariff: A Case Study Of A Sewage Plant

Understanding the energy cost tariffs or the models of commercial and industrial sectors is a crucial topic due to the high energy costs and its significant cost saving potentials. This paper has investigated the potential of the electrical energy cost saving using different energy cost tariffs of a...

Full description

Saved in:
Bibliographic Details
Main Authors: Sukri, Mohamad Firdaus, Mohd Tahir, Musthafah, Ab Razak, Juhari, Ab Rahman, Azhan
Format: Article
Language:English
Published: Praise Worthy Prize 2021
Online Access:http://eprints.utem.edu.my/id/eprint/25562/2/18_MFSUKRI_IREE2021.PDF
http://eprints.utem.edu.my/id/eprint/25562/
https://www.praiseworthyprize.org/jsm/index.php?journal=iree&page=article&op=view&path[]=19067
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utem.eprints.25562
record_format eprints
spelling my.utem.eprints.255622022-03-10T10:26:19Z http://eprints.utem.edu.my/id/eprint/25562/ Achieving Energy Cost Saving Using Best Energy Tariff: A Case Study Of A Sewage Plant Sukri, Mohamad Firdaus Mohd Tahir, Musthafah Ab Razak, Juhari Ab Rahman, Azhan Understanding the energy cost tariffs or the models of commercial and industrial sectors is a crucial topic due to the high energy costs and its significant cost saving potentials. This paper has investigated the potential of the electrical energy cost saving using different energy cost tariffs of a commercial sewage plant in Malaysia. The current energy tariff of B (Low Voltage Commercial) has been compared to four other possible energy tariffs. The actual electricity consumption of 2019 has been used as baseline data. It has been found out that at lower electricity consumption, energy tariff of D (Low Voltage Industrial (with discount)) has the greatest potential of energy cost saving compared to other tariffs. The superiority of this tariff leads to the highest cumulative energy cost saving. Based on the current and future projection of electricity consumption, it is proposed that the sewage plant switches its energy tariff to D (Low Voltage Industrial). Once approved, it is suggested to apply for a further 10% of energy cost saving through the special tariff of D (Low Voltage Industrial (with discount)) Praise Worthy Prize 2021-02 Article PeerReviewed text en http://eprints.utem.edu.my/id/eprint/25562/2/18_MFSUKRI_IREE2021.PDF Sukri, Mohamad Firdaus and Mohd Tahir, Musthafah and Ab Razak, Juhari and Ab Rahman, Azhan (2021) Achieving Energy Cost Saving Using Best Energy Tariff: A Case Study Of A Sewage Plant. International Review of Electrical Engineering (IREE), 16 (1). pp. 68-77. ISSN 1827- 6660 https://www.praiseworthyprize.org/jsm/index.php?journal=iree&page=article&op=view&path[]=19067 10.15866/iree.v16i1.19067
institution Universiti Teknikal Malaysia Melaka
building UTEM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknikal Malaysia Melaka
content_source UTEM Institutional Repository
url_provider http://eprints.utem.edu.my/
language English
description Understanding the energy cost tariffs or the models of commercial and industrial sectors is a crucial topic due to the high energy costs and its significant cost saving potentials. This paper has investigated the potential of the electrical energy cost saving using different energy cost tariffs of a commercial sewage plant in Malaysia. The current energy tariff of B (Low Voltage Commercial) has been compared to four other possible energy tariffs. The actual electricity consumption of 2019 has been used as baseline data. It has been found out that at lower electricity consumption, energy tariff of D (Low Voltage Industrial (with discount)) has the greatest potential of energy cost saving compared to other tariffs. The superiority of this tariff leads to the highest cumulative energy cost saving. Based on the current and future projection of electricity consumption, it is proposed that the sewage plant switches its energy tariff to D (Low Voltage Industrial). Once approved, it is suggested to apply for a further 10% of energy cost saving through the special tariff of D (Low Voltage Industrial (with discount))
format Article
author Sukri, Mohamad Firdaus
Mohd Tahir, Musthafah
Ab Razak, Juhari
Ab Rahman, Azhan
spellingShingle Sukri, Mohamad Firdaus
Mohd Tahir, Musthafah
Ab Razak, Juhari
Ab Rahman, Azhan
Achieving Energy Cost Saving Using Best Energy Tariff: A Case Study Of A Sewage Plant
author_facet Sukri, Mohamad Firdaus
Mohd Tahir, Musthafah
Ab Razak, Juhari
Ab Rahman, Azhan
author_sort Sukri, Mohamad Firdaus
title Achieving Energy Cost Saving Using Best Energy Tariff: A Case Study Of A Sewage Plant
title_short Achieving Energy Cost Saving Using Best Energy Tariff: A Case Study Of A Sewage Plant
title_full Achieving Energy Cost Saving Using Best Energy Tariff: A Case Study Of A Sewage Plant
title_fullStr Achieving Energy Cost Saving Using Best Energy Tariff: A Case Study Of A Sewage Plant
title_full_unstemmed Achieving Energy Cost Saving Using Best Energy Tariff: A Case Study Of A Sewage Plant
title_sort achieving energy cost saving using best energy tariff: a case study of a sewage plant
publisher Praise Worthy Prize
publishDate 2021
url http://eprints.utem.edu.my/id/eprint/25562/2/18_MFSUKRI_IREE2021.PDF
http://eprints.utem.edu.my/id/eprint/25562/
https://www.praiseworthyprize.org/jsm/index.php?journal=iree&page=article&op=view&path[]=19067
_version_ 1728055200801882112
score 13.214268