Performance Analysis Of Liquid-Cooled Panel System For Air Conditioner Using Peltier Effect

This study reviews the recent advances of thermoelectric materials, modelling approaches, and applications. Thermoelectric cooling systems have advantages over conventional cooling devices, including compact in size, light in weight, high reliability, no mechanical moving parts, no working fluid, be...

Full description

Saved in:
Bibliographic Details
Main Authors: Harun, Mohamad Haniff, Mohd Ab. Halim, Mohd Firdaus, Azahar, Arman Hadi, Yaakub, Muhamad Faizal, Md Basar, Mohd Farriz, Zainal Abidin, Amar Faiz, Mohd Aras, Mohd Shahrieel
Format: Article
Language:English
Published: Penerbit Akademia Baru 2019
Online Access:http://eprints.utem.edu.my/id/eprint/24316/2/2019_PERFORMANCE%20ANALYSIS%20OF%20LIQUID-COOLED%20PANEL%20SYSTEM%20FOR%20AIR%20CONDITIONER%20USING%20PELTIER%20EFFECT.PDF
http://eprints.utem.edu.my/id/eprint/24316/
http://www.akademiabaru.com/doc/ARFMTSV62_N1_P31_42.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utem.eprints.24316
record_format eprints
spelling my.utem.eprints.243162020-10-21T14:08:03Z http://eprints.utem.edu.my/id/eprint/24316/ Performance Analysis Of Liquid-Cooled Panel System For Air Conditioner Using Peltier Effect Harun, Mohamad Haniff Mohd Ab. Halim, Mohd Firdaus Azahar, Arman Hadi Yaakub, Muhamad Faizal Md Basar, Mohd Farriz Zainal Abidin, Amar Faiz Mohd Aras, Mohd Shahrieel This study reviews the recent advances of thermoelectric materials, modelling approaches, and applications. Thermoelectric cooling systems have advantages over conventional cooling devices, including compact in size, light in weight, high reliability, no mechanical moving parts, no working fluid, being powered by direct current, and easily switching between cooling and heating modes. In this study, it focused on the replacement of the outdoor unit (compressor) for conventional air-conditioner. This system using water as cooling agent in replacing refrigerant system. It involves using Peltier Effect which converts current to rise the temperature between the two junctions of the Peltier. The water will flow through these changes in temperature which results in cooling the air through the process. From this process, it taken 60 minutes in order to achieve 20.2 °C and consumed 1.3 A which is better rather using the conventional method. This can reduce the cost of the project in terms of maintenance, bills, materials and gases. This system can be operated without relying to the compressor which improve the systems in terms of noise, low electricity usage, small size and use water as coolant agent. Penerbit Akademia Baru 2019-10 Article PeerReviewed text en http://eprints.utem.edu.my/id/eprint/24316/2/2019_PERFORMANCE%20ANALYSIS%20OF%20LIQUID-COOLED%20PANEL%20SYSTEM%20FOR%20AIR%20CONDITIONER%20USING%20PELTIER%20EFFECT.PDF Harun, Mohamad Haniff and Mohd Ab. Halim, Mohd Firdaus and Azahar, Arman Hadi and Yaakub, Muhamad Faizal and Md Basar, Mohd Farriz and Zainal Abidin, Amar Faiz and Mohd Aras, Mohd Shahrieel (2019) Performance Analysis Of Liquid-Cooled Panel System For Air Conditioner Using Peltier Effect. Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, 62 (1). pp. 31-42. ISSN 2289-7879 http://www.akademiabaru.com/doc/ARFMTSV62_N1_P31_42.pdf
institution Universiti Teknikal Malaysia Melaka
building UTEM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknikal Malaysia Melaka
content_source UTEM Institutional Repository
url_provider http://eprints.utem.edu.my/
language English
description This study reviews the recent advances of thermoelectric materials, modelling approaches, and applications. Thermoelectric cooling systems have advantages over conventional cooling devices, including compact in size, light in weight, high reliability, no mechanical moving parts, no working fluid, being powered by direct current, and easily switching between cooling and heating modes. In this study, it focused on the replacement of the outdoor unit (compressor) for conventional air-conditioner. This system using water as cooling agent in replacing refrigerant system. It involves using Peltier Effect which converts current to rise the temperature between the two junctions of the Peltier. The water will flow through these changes in temperature which results in cooling the air through the process. From this process, it taken 60 minutes in order to achieve 20.2 °C and consumed 1.3 A which is better rather using the conventional method. This can reduce the cost of the project in terms of maintenance, bills, materials and gases. This system can be operated without relying to the compressor which improve the systems in terms of noise, low electricity usage, small size and use water as coolant agent.
format Article
author Harun, Mohamad Haniff
Mohd Ab. Halim, Mohd Firdaus
Azahar, Arman Hadi
Yaakub, Muhamad Faizal
Md Basar, Mohd Farriz
Zainal Abidin, Amar Faiz
Mohd Aras, Mohd Shahrieel
spellingShingle Harun, Mohamad Haniff
Mohd Ab. Halim, Mohd Firdaus
Azahar, Arman Hadi
Yaakub, Muhamad Faizal
Md Basar, Mohd Farriz
Zainal Abidin, Amar Faiz
Mohd Aras, Mohd Shahrieel
Performance Analysis Of Liquid-Cooled Panel System For Air Conditioner Using Peltier Effect
author_facet Harun, Mohamad Haniff
Mohd Ab. Halim, Mohd Firdaus
Azahar, Arman Hadi
Yaakub, Muhamad Faizal
Md Basar, Mohd Farriz
Zainal Abidin, Amar Faiz
Mohd Aras, Mohd Shahrieel
author_sort Harun, Mohamad Haniff
title Performance Analysis Of Liquid-Cooled Panel System For Air Conditioner Using Peltier Effect
title_short Performance Analysis Of Liquid-Cooled Panel System For Air Conditioner Using Peltier Effect
title_full Performance Analysis Of Liquid-Cooled Panel System For Air Conditioner Using Peltier Effect
title_fullStr Performance Analysis Of Liquid-Cooled Panel System For Air Conditioner Using Peltier Effect
title_full_unstemmed Performance Analysis Of Liquid-Cooled Panel System For Air Conditioner Using Peltier Effect
title_sort performance analysis of liquid-cooled panel system for air conditioner using peltier effect
publisher Penerbit Akademia Baru
publishDate 2019
url http://eprints.utem.edu.my/id/eprint/24316/2/2019_PERFORMANCE%20ANALYSIS%20OF%20LIQUID-COOLED%20PANEL%20SYSTEM%20FOR%20AIR%20CONDITIONER%20USING%20PELTIER%20EFFECT.PDF
http://eprints.utem.edu.my/id/eprint/24316/
http://www.akademiabaru.com/doc/ARFMTSV62_N1_P31_42.pdf
_version_ 1681492547745087488
score 13.160551