Analysis Of Light Bulb Temperature Control For Egg Incubator Design

This paper explained the analysis and findings of using light bulb as a thermal source for an incubator system. The inner dimension of the incubator is 26 cm (W) x 38 cm (L) x 26 cm (H). In the experiment, a temperature sensor that measures the inside temperature of the incubator used as a feedback...

Full description

Saved in:
Bibliographic Details
Main Authors: Che Amran, Aliza, Mohamad Saleh, Saleha, Abdul Kadir, Ahmad Muzaffar, Zainal, Ahmad Shukri, Mohd Nor, Rozilawati, Md. Rozali, Sahazati, Fauzi, Ahmad Hadinata
Format: Article
Language:English
Published: UTHM Publisher 2019
Online Access:http://eprints.utem.edu.my/id/eprint/24300/2/4715-ARTICLE%20TEXT-18936-1-10-20190905.PDF
http://eprints.utem.edu.my/id/eprint/24300/
https://publisher.uthm.edu.my/ojs/index.php/ijie/article/view/4715/3018
https://doi.org/10.30880/ijie.2019.11.04.031
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utem.eprints.24300
record_format eprints
spelling my.utem.eprints.243002020-12-03T11:58:30Z http://eprints.utem.edu.my/id/eprint/24300/ Analysis Of Light Bulb Temperature Control For Egg Incubator Design Che Amran, Aliza Mohamad Saleh, Saleha Abdul Kadir, Ahmad Muzaffar Zainal, Ahmad Shukri Mohd Nor, Rozilawati Md. Rozali, Sahazati Fauzi, Ahmad Hadinata This paper explained the analysis and findings of using light bulb as a thermal source for an incubator system. The inner dimension of the incubator is 26 cm (W) x 38 cm (L) x 26 cm (H). In the experiment, a temperature sensor that measures the inside temperature of the incubator used as a feedback signal. To run the experiments, number of light bulbs and its type were determined. There are three types of bulb used i.e. Incandescent Light (IL Bulb), Compact Fluorescent Lamp (CFL Bulb) and Light Emitting Diode (LED Bulb). Three fixtures are proposed for each bulb type, i.e. one-bulb fixture, two-bulb fixture and three-bulb fixture. Apart from that, three control modes were tested, i.e. Mode 1, Mode 2 and Mode 3. Mode 1 is ON-OFF bulb control. Mode 2 is ON-OFF bulb control, as well as ON-OFF ventilation fan control. Finally, Mode 3 is only ON bulb control and ON-OFF ventilation fans The experimental results showed that, for the chosen incubator size, threebulb fixture IL-type light bulb controlled with Mode 3 control gave shorter time to reach the set point then return to set point after overshoot UTHM Publisher 2019 Article PeerReviewed text en http://eprints.utem.edu.my/id/eprint/24300/2/4715-ARTICLE%20TEXT-18936-1-10-20190905.PDF Che Amran, Aliza and Mohamad Saleh, Saleha and Abdul Kadir, Ahmad Muzaffar and Zainal, Ahmad Shukri and Mohd Nor, Rozilawati and Md. Rozali, Sahazati and Fauzi, Ahmad Hadinata (2019) Analysis Of Light Bulb Temperature Control For Egg Incubator Design. International Journal of Integrated Engineering, 11 (4). pp. 268-276. ISSN 2229-838X (Unpublished) https://publisher.uthm.edu.my/ojs/index.php/ijie/article/view/4715/3018 https://doi.org/10.30880/ijie.2019.11.04.031
institution Universiti Teknikal Malaysia Melaka
building UTEM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknikal Malaysia Melaka
content_source UTEM Institutional Repository
url_provider http://eprints.utem.edu.my/
language English
description This paper explained the analysis and findings of using light bulb as a thermal source for an incubator system. The inner dimension of the incubator is 26 cm (W) x 38 cm (L) x 26 cm (H). In the experiment, a temperature sensor that measures the inside temperature of the incubator used as a feedback signal. To run the experiments, number of light bulbs and its type were determined. There are three types of bulb used i.e. Incandescent Light (IL Bulb), Compact Fluorescent Lamp (CFL Bulb) and Light Emitting Diode (LED Bulb). Three fixtures are proposed for each bulb type, i.e. one-bulb fixture, two-bulb fixture and three-bulb fixture. Apart from that, three control modes were tested, i.e. Mode 1, Mode 2 and Mode 3. Mode 1 is ON-OFF bulb control. Mode 2 is ON-OFF bulb control, as well as ON-OFF ventilation fan control. Finally, Mode 3 is only ON bulb control and ON-OFF ventilation fans The experimental results showed that, for the chosen incubator size, threebulb fixture IL-type light bulb controlled with Mode 3 control gave shorter time to reach the set point then return to set point after overshoot
format Article
author Che Amran, Aliza
Mohamad Saleh, Saleha
Abdul Kadir, Ahmad Muzaffar
Zainal, Ahmad Shukri
Mohd Nor, Rozilawati
Md. Rozali, Sahazati
Fauzi, Ahmad Hadinata
spellingShingle Che Amran, Aliza
Mohamad Saleh, Saleha
Abdul Kadir, Ahmad Muzaffar
Zainal, Ahmad Shukri
Mohd Nor, Rozilawati
Md. Rozali, Sahazati
Fauzi, Ahmad Hadinata
Analysis Of Light Bulb Temperature Control For Egg Incubator Design
author_facet Che Amran, Aliza
Mohamad Saleh, Saleha
Abdul Kadir, Ahmad Muzaffar
Zainal, Ahmad Shukri
Mohd Nor, Rozilawati
Md. Rozali, Sahazati
Fauzi, Ahmad Hadinata
author_sort Che Amran, Aliza
title Analysis Of Light Bulb Temperature Control For Egg Incubator Design
title_short Analysis Of Light Bulb Temperature Control For Egg Incubator Design
title_full Analysis Of Light Bulb Temperature Control For Egg Incubator Design
title_fullStr Analysis Of Light Bulb Temperature Control For Egg Incubator Design
title_full_unstemmed Analysis Of Light Bulb Temperature Control For Egg Incubator Design
title_sort analysis of light bulb temperature control for egg incubator design
publisher UTHM Publisher
publishDate 2019
url http://eprints.utem.edu.my/id/eprint/24300/2/4715-ARTICLE%20TEXT-18936-1-10-20190905.PDF
http://eprints.utem.edu.my/id/eprint/24300/
https://publisher.uthm.edu.my/ojs/index.php/ijie/article/view/4715/3018
https://doi.org/10.30880/ijie.2019.11.04.031
_version_ 1687397224666890240
score 13.211869