A Verification Of Periodogram Technique For Harmonic Source Diagnostic Analytic By Using Logistic Regression
A harmonic source diagnostic analytic is vital to identify the root causes and type of harmonic source in power system. This paper introduces a verification of periodogram technique to diagnose harmonic sources by using logistic regression classifier. A periodogram gives a correct and accurate class...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Institute of Advanced Engineering and Science (IAES)
2019
|
Online Access: | http://eprints.utem.edu.my/id/eprint/24176/2/A_VERIFICATION_OF_PERIODOGRAM_TECHNIQUE_FOR_HARMON.PDF http://eprints.utem.edu.my/id/eprint/24176/ http://journal.uad.ac.id/index.php/TELKOMNIKA/article/view/10390 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utem.eprints.24176 |
---|---|
record_format |
eprints |
spelling |
my.utem.eprints.241762020-07-29T14:39:37Z http://eprints.utem.edu.my/id/eprint/24176/ A Verification Of Periodogram Technique For Harmonic Source Diagnostic Analytic By Using Logistic Regression Jopri, Mohd Hatta Manap, Mustafa Yusoff, Mohd Rahimi Azahar, Arman Hadi Abdullah, Abdul Rahim Karim R., Karim R. A harmonic source diagnostic analytic is vital to identify the root causes and type of harmonic source in power system. This paper introduces a verification of periodogram technique to diagnose harmonic sources by using logistic regression classifier. A periodogram gives a correct and accurate classification of harmonic signals. Signature recognition pattern is used to distinguish the harmonic sources accurately by obtaining the distribution of harmonic and interharmonic components and the harmonic contribution changes. This is achieved by using the significant signature recognition of harmonic producing load obtained from the harmonic contribution changes. To verify the performance of the propose method, a logistic regression classifier will analyse the result and give the accuracy and positive rate percentage of the propose method. The adequacy of the proposed methodology is tested and verified on distribution system for several rectifier and inverter-based loads. Institute of Advanced Engineering and Science (IAES) 2019-02 Article PeerReviewed text en http://eprints.utem.edu.my/id/eprint/24176/2/A_VERIFICATION_OF_PERIODOGRAM_TECHNIQUE_FOR_HARMON.PDF Jopri, Mohd Hatta and Manap, Mustafa and Yusoff, Mohd Rahimi and Azahar, Arman Hadi and Abdullah, Abdul Rahim and Karim R., Karim R. (2019) A Verification Of Periodogram Technique For Harmonic Source Diagnostic Analytic By Using Logistic Regression. Telkomnika (Telecommunication Computing Electronics and Control), 17 (1). pp. 497-507. ISSN 1693-6930 http://journal.uad.ac.id/index.php/TELKOMNIKA/article/view/10390 10.12928/TELKOMNIKA.v17i1.10390 |
institution |
Universiti Teknikal Malaysia Melaka |
building |
UTEM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknikal Malaysia Melaka |
content_source |
UTEM Institutional Repository |
url_provider |
http://eprints.utem.edu.my/ |
language |
English |
description |
A harmonic source diagnostic analytic is vital to identify the root causes and type of harmonic source in power system. This paper introduces a verification of periodogram technique to diagnose harmonic sources by using logistic regression classifier. A periodogram gives a correct and accurate classification of harmonic signals. Signature recognition pattern is used to distinguish the harmonic sources accurately by obtaining the distribution of harmonic and interharmonic components and the harmonic contribution changes. This is achieved by using the significant signature recognition of harmonic producing load obtained from the harmonic contribution changes. To verify the performance of the propose method, a logistic regression classifier will analyse the result and give the accuracy and positive rate percentage of the propose method. The adequacy of the proposed methodology is tested and verified on distribution system for several rectifier and inverter-based loads. |
format |
Article |
author |
Jopri, Mohd Hatta Manap, Mustafa Yusoff, Mohd Rahimi Azahar, Arman Hadi Abdullah, Abdul Rahim Karim R., Karim R. |
spellingShingle |
Jopri, Mohd Hatta Manap, Mustafa Yusoff, Mohd Rahimi Azahar, Arman Hadi Abdullah, Abdul Rahim Karim R., Karim R. A Verification Of Periodogram Technique For Harmonic Source Diagnostic Analytic By Using Logistic Regression |
author_facet |
Jopri, Mohd Hatta Manap, Mustafa Yusoff, Mohd Rahimi Azahar, Arman Hadi Abdullah, Abdul Rahim Karim R., Karim R. |
author_sort |
Jopri, Mohd Hatta |
title |
A Verification Of Periodogram Technique For Harmonic Source Diagnostic Analytic By Using Logistic Regression |
title_short |
A Verification Of Periodogram Technique For Harmonic Source Diagnostic Analytic By Using Logistic Regression |
title_full |
A Verification Of Periodogram Technique For Harmonic Source Diagnostic Analytic By Using Logistic Regression |
title_fullStr |
A Verification Of Periodogram Technique For Harmonic Source Diagnostic Analytic By Using Logistic Regression |
title_full_unstemmed |
A Verification Of Periodogram Technique For Harmonic Source Diagnostic Analytic By Using Logistic Regression |
title_sort |
verification of periodogram technique for harmonic source diagnostic analytic by using logistic regression |
publisher |
Institute of Advanced Engineering and Science (IAES) |
publishDate |
2019 |
url |
http://eprints.utem.edu.my/id/eprint/24176/2/A_VERIFICATION_OF_PERIODOGRAM_TECHNIQUE_FOR_HARMON.PDF http://eprints.utem.edu.my/id/eprint/24176/ http://journal.uad.ac.id/index.php/TELKOMNIKA/article/view/10390 |
_version_ |
1675330910453497856 |
score |
13.211869 |