A Verification Of Periodogram Technique For Harmonic Source Diagnostic Analytic By Using Logistic Regression

A harmonic source diagnostic analytic is vital to identify the root causes and type of harmonic source in power system. This paper introduces a verification of periodogram technique to diagnose harmonic sources by using logistic regression classifier. A periodogram gives a correct and accurate class...

Full description

Saved in:
Bibliographic Details
Main Authors: Jopri, Mohd Hatta, Manap, Mustafa, Yusoff, Mohd Rahimi, Azahar, Arman Hadi, Abdullah, Abdul Rahim, Karim R., Karim R.
Format: Article
Language:English
Published: Institute of Advanced Engineering and Science (IAES) 2019
Online Access:http://eprints.utem.edu.my/id/eprint/24176/2/A_VERIFICATION_OF_PERIODOGRAM_TECHNIQUE_FOR_HARMON.PDF
http://eprints.utem.edu.my/id/eprint/24176/
http://journal.uad.ac.id/index.php/TELKOMNIKA/article/view/10390
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utem.eprints.24176
record_format eprints
spelling my.utem.eprints.241762020-07-29T14:39:37Z http://eprints.utem.edu.my/id/eprint/24176/ A Verification Of Periodogram Technique For Harmonic Source Diagnostic Analytic By Using Logistic Regression Jopri, Mohd Hatta Manap, Mustafa Yusoff, Mohd Rahimi Azahar, Arman Hadi Abdullah, Abdul Rahim Karim R., Karim R. A harmonic source diagnostic analytic is vital to identify the root causes and type of harmonic source in power system. This paper introduces a verification of periodogram technique to diagnose harmonic sources by using logistic regression classifier. A periodogram gives a correct and accurate classification of harmonic signals. Signature recognition pattern is used to distinguish the harmonic sources accurately by obtaining the distribution of harmonic and interharmonic components and the harmonic contribution changes. This is achieved by using the significant signature recognition of harmonic producing load obtained from the harmonic contribution changes. To verify the performance of the propose method, a logistic regression classifier will analyse the result and give the accuracy and positive rate percentage of the propose method. The adequacy of the proposed methodology is tested and verified on distribution system for several rectifier and inverter-based loads. Institute of Advanced Engineering and Science (IAES) 2019-02 Article PeerReviewed text en http://eprints.utem.edu.my/id/eprint/24176/2/A_VERIFICATION_OF_PERIODOGRAM_TECHNIQUE_FOR_HARMON.PDF Jopri, Mohd Hatta and Manap, Mustafa and Yusoff, Mohd Rahimi and Azahar, Arman Hadi and Abdullah, Abdul Rahim and Karim R., Karim R. (2019) A Verification Of Periodogram Technique For Harmonic Source Diagnostic Analytic By Using Logistic Regression. Telkomnika (Telecommunication Computing Electronics and Control), 17 (1). pp. 497-507. ISSN 1693-6930 http://journal.uad.ac.id/index.php/TELKOMNIKA/article/view/10390 10.12928/TELKOMNIKA.v17i1.10390
institution Universiti Teknikal Malaysia Melaka
building UTEM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknikal Malaysia Melaka
content_source UTEM Institutional Repository
url_provider http://eprints.utem.edu.my/
language English
description A harmonic source diagnostic analytic is vital to identify the root causes and type of harmonic source in power system. This paper introduces a verification of periodogram technique to diagnose harmonic sources by using logistic regression classifier. A periodogram gives a correct and accurate classification of harmonic signals. Signature recognition pattern is used to distinguish the harmonic sources accurately by obtaining the distribution of harmonic and interharmonic components and the harmonic contribution changes. This is achieved by using the significant signature recognition of harmonic producing load obtained from the harmonic contribution changes. To verify the performance of the propose method, a logistic regression classifier will analyse the result and give the accuracy and positive rate percentage of the propose method. The adequacy of the proposed methodology is tested and verified on distribution system for several rectifier and inverter-based loads.
format Article
author Jopri, Mohd Hatta
Manap, Mustafa
Yusoff, Mohd Rahimi
Azahar, Arman Hadi
Abdullah, Abdul Rahim
Karim R., Karim R.
spellingShingle Jopri, Mohd Hatta
Manap, Mustafa
Yusoff, Mohd Rahimi
Azahar, Arman Hadi
Abdullah, Abdul Rahim
Karim R., Karim R.
A Verification Of Periodogram Technique For Harmonic Source Diagnostic Analytic By Using Logistic Regression
author_facet Jopri, Mohd Hatta
Manap, Mustafa
Yusoff, Mohd Rahimi
Azahar, Arman Hadi
Abdullah, Abdul Rahim
Karim R., Karim R.
author_sort Jopri, Mohd Hatta
title A Verification Of Periodogram Technique For Harmonic Source Diagnostic Analytic By Using Logistic Regression
title_short A Verification Of Periodogram Technique For Harmonic Source Diagnostic Analytic By Using Logistic Regression
title_full A Verification Of Periodogram Technique For Harmonic Source Diagnostic Analytic By Using Logistic Regression
title_fullStr A Verification Of Periodogram Technique For Harmonic Source Diagnostic Analytic By Using Logistic Regression
title_full_unstemmed A Verification Of Periodogram Technique For Harmonic Source Diagnostic Analytic By Using Logistic Regression
title_sort verification of periodogram technique for harmonic source diagnostic analytic by using logistic regression
publisher Institute of Advanced Engineering and Science (IAES)
publishDate 2019
url http://eprints.utem.edu.my/id/eprint/24176/2/A_VERIFICATION_OF_PERIODOGRAM_TECHNIQUE_FOR_HARMON.PDF
http://eprints.utem.edu.my/id/eprint/24176/
http://journal.uad.ac.id/index.php/TELKOMNIKA/article/view/10390
_version_ 1675330910453497856
score 13.211869