Identification Of Harmonic Source For Electric Arc Furnace Load Using Fast-Fourier Transform

Harmonic pollution has become a major problem in electrical power networks which can cause problems like the reduction load’s lifetime, failure of protection devices to operate efficiently, instabilities of power system interference in operating systems and all these can contribute to economic losse...

Full description

Saved in:
Bibliographic Details
Main Author: Saleh, Nurhazwani
Format: Thesis
Language:English
English
Published: 2018
Subjects:
Online Access:http://eprints.utem.edu.my/id/eprint/24121/1/Identification%20Of%20Harmonic%20Source%20For%20Electric%20Arc%20Furnace%20Load%20Using%20Fast-Fourier%20Transform%20-%20Nurhazwani%20Saleh%20-%2024%20Pages.pdf
http://eprints.utem.edu.my/id/eprint/24121/2/Identification%20Of%20Harmonic%20Source%20For%20Electric%20Arc%20Furnace%20Load%20Using%20Fast-Fourier%20Transform.pdf
http://eprints.utem.edu.my/id/eprint/24121/
http://plh.utem.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=115450
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utem.eprints.24121
record_format eprints
spelling my.utem.eprints.241212022-02-21T15:05:21Z http://eprints.utem.edu.my/id/eprint/24121/ Identification Of Harmonic Source For Electric Arc Furnace Load Using Fast-Fourier Transform Saleh, Nurhazwani T Technology (General) TK Electrical engineering. Electronics Nuclear engineering Harmonic pollution has become a major problem in electrical power networks which can cause problems like the reduction load’s lifetime, failure of protection devices to operate efficiently, instabilities of power system interference in operating systems and all these can contribute to economic losses and downtime. Therefore, harmonic source identification is one of the major problems. Proper identification of the harmonics source is an essential for developing penalty based schemes for harmonic generation and for the design of mitigation equipment to reduce harmonic. This dissertation aims to identify and analyze the harmonics source in power system using Fast-Fourier Transform (FFT) with effective cost efficiencies using single-point measurement approach. The sources of harmonic that been focused in this study is Electric Arc Furnace and finally, the applicability of the modelling system is tested with another harmonic source, Rectifier. The signification finding of this research shows the harmonic sources location can be identified by referring to the relationship between fundamental impedance 2018 Thesis NonPeerReviewed text en http://eprints.utem.edu.my/id/eprint/24121/1/Identification%20Of%20Harmonic%20Source%20For%20Electric%20Arc%20Furnace%20Load%20Using%20Fast-Fourier%20Transform%20-%20Nurhazwani%20Saleh%20-%2024%20Pages.pdf text en http://eprints.utem.edu.my/id/eprint/24121/2/Identification%20Of%20Harmonic%20Source%20For%20Electric%20Arc%20Furnace%20Load%20Using%20Fast-Fourier%20Transform.pdf Saleh, Nurhazwani (2018) Identification Of Harmonic Source For Electric Arc Furnace Load Using Fast-Fourier Transform. Masters thesis, Universiti Teknikal Malaysia Melaka. http://plh.utem.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=115450
institution Universiti Teknikal Malaysia Melaka
building UTEM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknikal Malaysia Melaka
content_source UTEM Institutional Repository
url_provider http://eprints.utem.edu.my/
language English
English
topic T Technology (General)
TK Electrical engineering. Electronics Nuclear engineering
spellingShingle T Technology (General)
TK Electrical engineering. Electronics Nuclear engineering
Saleh, Nurhazwani
Identification Of Harmonic Source For Electric Arc Furnace Load Using Fast-Fourier Transform
description Harmonic pollution has become a major problem in electrical power networks which can cause problems like the reduction load’s lifetime, failure of protection devices to operate efficiently, instabilities of power system interference in operating systems and all these can contribute to economic losses and downtime. Therefore, harmonic source identification is one of the major problems. Proper identification of the harmonics source is an essential for developing penalty based schemes for harmonic generation and for the design of mitigation equipment to reduce harmonic. This dissertation aims to identify and analyze the harmonics source in power system using Fast-Fourier Transform (FFT) with effective cost efficiencies using single-point measurement approach. The sources of harmonic that been focused in this study is Electric Arc Furnace and finally, the applicability of the modelling system is tested with another harmonic source, Rectifier. The signification finding of this research shows the harmonic sources location can be identified by referring to the relationship between fundamental impedance
format Thesis
author Saleh, Nurhazwani
author_facet Saleh, Nurhazwani
author_sort Saleh, Nurhazwani
title Identification Of Harmonic Source For Electric Arc Furnace Load Using Fast-Fourier Transform
title_short Identification Of Harmonic Source For Electric Arc Furnace Load Using Fast-Fourier Transform
title_full Identification Of Harmonic Source For Electric Arc Furnace Load Using Fast-Fourier Transform
title_fullStr Identification Of Harmonic Source For Electric Arc Furnace Load Using Fast-Fourier Transform
title_full_unstemmed Identification Of Harmonic Source For Electric Arc Furnace Load Using Fast-Fourier Transform
title_sort identification of harmonic source for electric arc furnace load using fast-fourier transform
publishDate 2018
url http://eprints.utem.edu.my/id/eprint/24121/1/Identification%20Of%20Harmonic%20Source%20For%20Electric%20Arc%20Furnace%20Load%20Using%20Fast-Fourier%20Transform%20-%20Nurhazwani%20Saleh%20-%2024%20Pages.pdf
http://eprints.utem.edu.my/id/eprint/24121/2/Identification%20Of%20Harmonic%20Source%20For%20Electric%20Arc%20Furnace%20Load%20Using%20Fast-Fourier%20Transform.pdf
http://eprints.utem.edu.my/id/eprint/24121/
http://plh.utem.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=115450
_version_ 1725976112666771456
score 13.160551