Analysis Of Multiphase Transformer Supplying A Static And Dynamic Load

Transformers are able to step up or step down an output voltage from their input. It also can be used to directly supply an electrical motor when a constant frequency operation is required. Here, the research is focusing on designing a three-to-five phase transformer that acts as static phase conve...

Full description

Saved in:
Bibliographic Details
Main Authors: Nor Azizah, Mohd Yusoff, Kasrul, Abdul Karim, Sharin, Ab Ghani, Fazlli, Patkar, Siti Azura, Ahmad Tarusan, Auzani, Jidin
Format: Article
Language:English
Published: Asian Research Publishing Network (ARPN) 2016
Subjects:
Online Access:http://eprints.utem.edu.my/id/eprint/17092/1/Analysis%20Of%20Multiphase%20Transformer%20Supplying%20A%20Static%20And%20Dynamic%20Load.pdf
http://eprints.utem.edu.my/id/eprint/17092/
http://www.arpnjournals.org/jeas/research_papers/rp_2016/jeas_0716_4713.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utem.eprints.17092
record_format eprints
spelling my.utem.eprints.170922021-09-08T20:06:51Z http://eprints.utem.edu.my/id/eprint/17092/ Analysis Of Multiphase Transformer Supplying A Static And Dynamic Load Nor Azizah, Mohd Yusoff Kasrul, Abdul Karim Sharin, Ab Ghani Fazlli, Patkar Siti Azura, Ahmad Tarusan Auzani, Jidin T Technology (General) Transformers are able to step up or step down an output voltage from their input. It also can be used to directly supply an electrical motor when a constant frequency operation is required. Here, the research is focusing on designing a three-to-five phase transformer that acts as static phase converters for supplying a balance five-phase load. The designing process of the transformer is described based on the graphical phasor diagram that is flexible and easy to be implemented. At the end, the performances of the designed transformer are evaluated using a static and dynamic load. The designed three-to-five phase transformer is able to maintain a balance five phase voltage for several type and level of load as shown in experimental result. Asian Research Publishing Network (ARPN) 2016-07 Article PeerReviewed text en http://eprints.utem.edu.my/id/eprint/17092/1/Analysis%20Of%20Multiphase%20Transformer%20Supplying%20A%20Static%20And%20Dynamic%20Load.pdf Nor Azizah, Mohd Yusoff and Kasrul, Abdul Karim and Sharin, Ab Ghani and Fazlli, Patkar and Siti Azura, Ahmad Tarusan and Auzani, Jidin (2016) Analysis Of Multiphase Transformer Supplying A Static And Dynamic Load. ARPN Journal Of Engineering And Applied Sciences, 11 (14). pp. 8987-8991. ISSN 1819-6608 http://www.arpnjournals.org/jeas/research_papers/rp_2016/jeas_0716_4713.pdf
institution Universiti Teknikal Malaysia Melaka
building UTEM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknikal Malaysia Melaka
content_source UTEM Institutional Repository
url_provider http://eprints.utem.edu.my/
language English
topic T Technology (General)
spellingShingle T Technology (General)
Nor Azizah, Mohd Yusoff
Kasrul, Abdul Karim
Sharin, Ab Ghani
Fazlli, Patkar
Siti Azura, Ahmad Tarusan
Auzani, Jidin
Analysis Of Multiphase Transformer Supplying A Static And Dynamic Load
description Transformers are able to step up or step down an output voltage from their input. It also can be used to directly supply an electrical motor when a constant frequency operation is required. Here, the research is focusing on designing a three-to-five phase transformer that acts as static phase converters for supplying a balance five-phase load. The designing process of the transformer is described based on the graphical phasor diagram that is flexible and easy to be implemented. At the end, the performances of the designed transformer are evaluated using a static and dynamic load. The designed three-to-five phase transformer is able to maintain a balance five phase voltage for several type and level of load as shown in experimental result.
format Article
author Nor Azizah, Mohd Yusoff
Kasrul, Abdul Karim
Sharin, Ab Ghani
Fazlli, Patkar
Siti Azura, Ahmad Tarusan
Auzani, Jidin
author_facet Nor Azizah, Mohd Yusoff
Kasrul, Abdul Karim
Sharin, Ab Ghani
Fazlli, Patkar
Siti Azura, Ahmad Tarusan
Auzani, Jidin
author_sort Nor Azizah, Mohd Yusoff
title Analysis Of Multiphase Transformer Supplying A Static And Dynamic Load
title_short Analysis Of Multiphase Transformer Supplying A Static And Dynamic Load
title_full Analysis Of Multiphase Transformer Supplying A Static And Dynamic Load
title_fullStr Analysis Of Multiphase Transformer Supplying A Static And Dynamic Load
title_full_unstemmed Analysis Of Multiphase Transformer Supplying A Static And Dynamic Load
title_sort analysis of multiphase transformer supplying a static and dynamic load
publisher Asian Research Publishing Network (ARPN)
publishDate 2016
url http://eprints.utem.edu.my/id/eprint/17092/1/Analysis%20Of%20Multiphase%20Transformer%20Supplying%20A%20Static%20And%20Dynamic%20Load.pdf
http://eprints.utem.edu.my/id/eprint/17092/
http://www.arpnjournals.org/jeas/research_papers/rp_2016/jeas_0716_4713.pdf
_version_ 1710679418474594304
score 13.160551