Comparison analysis of indirect FOC induction motor drive using PI, anti-windup and pre filter schemes

This paper presents the speed performance analysis of indirect Field Oriented Control (FOC) induction motor drive by applying Proportional Integral (PI)controller, PI with Anti-Windup (PIAW) and Pre- Filter (PF). The objective of this experiment is to have quantitative comparison between the contro...

Full description

Saved in:
Bibliographic Details
Main Authors: Talib, Md Hairul Nizam, Ibrahim, Zulkifilie, Abd Rahim, Nasrudin, Abu Hasim, Ahmad Shukri
Format: Article
Language:English
Published: Institute of Advanced Engineering and Science (IAES) 2014
Subjects:
Online Access:http://eprints.utem.edu.my/id/eprint/14678/1/6250-14542-1-PB_IJPES_Comparison_FOC_PI_AWPI_and_PF.pdf
http://eprints.utem.edu.my/id/eprint/14678/
http://www.iaesjournal.com/online/index
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utem.eprints.14678
record_format eprints
spelling my.utem.eprints.146782015-07-06T07:17:13Z http://eprints.utem.edu.my/id/eprint/14678/ Comparison analysis of indirect FOC induction motor drive using PI, anti-windup and pre filter schemes Talib, Md Hairul Nizam Ibrahim, Zulkifilie Abd Rahim, Nasrudin Abu Hasim, Ahmad Shukri TK Electrical engineering. Electronics Nuclear engineering This paper presents the speed performance analysis of indirect Field Oriented Control (FOC) induction motor drive by applying Proportional Integral (PI)controller, PI with Anti-Windup (PIAW) and Pre- Filter (PF). The objective of this experiment is to have quantitative comparison between the controller strategies towards the performance of the motor in term of speed tracking and load rejection capability in low, medium and rated speed operation. In the first part, PI controller is applied to the FOC induction motor drive which the gain is obtained based on determined Induction Motor (IM) motor parameters. Secondly an AWPI strategy is added to the outer loop and finally, PF is added to the system. The Space Vector Pulse Width Modulation (SVPWM) technique is used to control the voltage source inverter and complete vector control scheme of the IM drive is tested by using a DSpace 1103 controller board. The analysis of the results shows that, the PI and AWPI controller schemes produce similar performance at low speed operation. However, for the medium and rated speed operation the AWPI scheme shown significant improvement in reducing the overshoot problem and improving the setting time. The PF scheme on the other hand, produces a slower speed and torque response for all tested speed operation. All schemes show similar performance for load disturbance rejection capability. Institute of Advanced Engineering and Science (IAES) 2014-07-10 Article PeerReviewed application/pdf en http://eprints.utem.edu.my/id/eprint/14678/1/6250-14542-1-PB_IJPES_Comparison_FOC_PI_AWPI_and_PF.pdf Talib, Md Hairul Nizam and Ibrahim, Zulkifilie and Abd Rahim, Nasrudin and Abu Hasim, Ahmad Shukri (2014) Comparison analysis of indirect FOC induction motor drive using PI, anti-windup and pre filter schemes. International Journal of Power Electronics and Drive Systems (IJPEDS, 5 (2). pp. 219-229. ISSN 2088-8694 http://www.iaesjournal.com/online/index
institution Universiti Teknikal Malaysia Melaka
building UTEM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknikal Malaysia Melaka
content_source UTEM Institutional Repository
url_provider http://eprints.utem.edu.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Talib, Md Hairul Nizam
Ibrahim, Zulkifilie
Abd Rahim, Nasrudin
Abu Hasim, Ahmad Shukri
Comparison analysis of indirect FOC induction motor drive using PI, anti-windup and pre filter schemes
description This paper presents the speed performance analysis of indirect Field Oriented Control (FOC) induction motor drive by applying Proportional Integral (PI)controller, PI with Anti-Windup (PIAW) and Pre- Filter (PF). The objective of this experiment is to have quantitative comparison between the controller strategies towards the performance of the motor in term of speed tracking and load rejection capability in low, medium and rated speed operation. In the first part, PI controller is applied to the FOC induction motor drive which the gain is obtained based on determined Induction Motor (IM) motor parameters. Secondly an AWPI strategy is added to the outer loop and finally, PF is added to the system. The Space Vector Pulse Width Modulation (SVPWM) technique is used to control the voltage source inverter and complete vector control scheme of the IM drive is tested by using a DSpace 1103 controller board. The analysis of the results shows that, the PI and AWPI controller schemes produce similar performance at low speed operation. However, for the medium and rated speed operation the AWPI scheme shown significant improvement in reducing the overshoot problem and improving the setting time. The PF scheme on the other hand, produces a slower speed and torque response for all tested speed operation. All schemes show similar performance for load disturbance rejection capability.
format Article
author Talib, Md Hairul Nizam
Ibrahim, Zulkifilie
Abd Rahim, Nasrudin
Abu Hasim, Ahmad Shukri
author_facet Talib, Md Hairul Nizam
Ibrahim, Zulkifilie
Abd Rahim, Nasrudin
Abu Hasim, Ahmad Shukri
author_sort Talib, Md Hairul Nizam
title Comparison analysis of indirect FOC induction motor drive using PI, anti-windup and pre filter schemes
title_short Comparison analysis of indirect FOC induction motor drive using PI, anti-windup and pre filter schemes
title_full Comparison analysis of indirect FOC induction motor drive using PI, anti-windup and pre filter schemes
title_fullStr Comparison analysis of indirect FOC induction motor drive using PI, anti-windup and pre filter schemes
title_full_unstemmed Comparison analysis of indirect FOC induction motor drive using PI, anti-windup and pre filter schemes
title_sort comparison analysis of indirect foc induction motor drive using pi, anti-windup and pre filter schemes
publisher Institute of Advanced Engineering and Science (IAES)
publishDate 2014
url http://eprints.utem.edu.my/id/eprint/14678/1/6250-14542-1-PB_IJPES_Comparison_FOC_PI_AWPI_and_PF.pdf
http://eprints.utem.edu.my/id/eprint/14678/
http://www.iaesjournal.com/online/index
_version_ 1665905603146416128