Eye closure and open detection using Adaptive Thresholding Histogram Enhancement (ATHE) technique and connected components utilisation

Eye closure detection is an important operation prior to carry out the main algorithm such as iris recognition algorithms, and eye tracking algorithms. This paper introduces a method to detect eye closure using Adaptive Thresholding Histogram Enhancement (ATHE) technique and connected component util...

Full description

Saved in:
Bibliographic Details
Main Authors: Mat Ibrahim, Masrullizam, Awang Md Isa, Azmi, Darsono, Abd Majid
Format: Conference or Workshop Item
Language:English
Published: 2014
Subjects:
Online Access:http://eprints.utem.edu.my/id/eprint/14024/1/Eye_Closure_and_Open_Detection_Using_Adaptive_Thresholding_Histogram_Enhancement_%28ATHE%29.pdf
http://eprints.utem.edu.my/id/eprint/14024/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utem.eprints.14024
record_format eprints
spelling my.utem.eprints.140242023-05-30T12:25:00Z http://eprints.utem.edu.my/id/eprint/14024/ Eye closure and open detection using Adaptive Thresholding Histogram Enhancement (ATHE) technique and connected components utilisation Mat Ibrahim, Masrullizam Awang Md Isa, Azmi Darsono, Abd Majid QA75 Electronic computers. Computer science Eye closure detection is an important operation prior to carry out the main algorithm such as iris recognition algorithms, and eye tracking algorithms. This paper introduces a method to detect eye closure using Adaptive Thresholding Histogram Enhancement (ATHE) technique and connected component utilisation. The ATHE technique is a combination of histogram enhancement and estimation threshold technique. Firstly, in this proposed method the eye region is required to be localised. The ATHE technique enhances the eye region image then and yield the threshold value to segment the iris region. Based on the segmentation result, the connected components of binary image are used to classify the state of eye whether open or close. This classification is based on the shape and size of segmented region. The performance of the proposed technique is tested and validated by using UBIRIS, MMU and CASIA iris image database. 2014 Conference or Workshop Item PeerReviewed text en http://eprints.utem.edu.my/id/eprint/14024/1/Eye_Closure_and_Open_Detection_Using_Adaptive_Thresholding_Histogram_Enhancement_%28ATHE%29.pdf Mat Ibrahim, Masrullizam and Awang Md Isa, Azmi and Darsono, Abd Majid (2014) Eye closure and open detection using Adaptive Thresholding Histogram Enhancement (ATHE) technique and connected components utilisation. In: Intelligent and Advanced Systems (ICIAS), 2014 5th International Conference, 3-5 June 2014 , KLCC Kuala Lumpur.
institution Universiti Teknikal Malaysia Melaka
building UTEM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknikal Malaysia Melaka
content_source UTEM Institutional Repository
url_provider http://eprints.utem.edu.my/
language English
topic QA75 Electronic computers. Computer science
spellingShingle QA75 Electronic computers. Computer science
Mat Ibrahim, Masrullizam
Awang Md Isa, Azmi
Darsono, Abd Majid
Eye closure and open detection using Adaptive Thresholding Histogram Enhancement (ATHE) technique and connected components utilisation
description Eye closure detection is an important operation prior to carry out the main algorithm such as iris recognition algorithms, and eye tracking algorithms. This paper introduces a method to detect eye closure using Adaptive Thresholding Histogram Enhancement (ATHE) technique and connected component utilisation. The ATHE technique is a combination of histogram enhancement and estimation threshold technique. Firstly, in this proposed method the eye region is required to be localised. The ATHE technique enhances the eye region image then and yield the threshold value to segment the iris region. Based on the segmentation result, the connected components of binary image are used to classify the state of eye whether open or close. This classification is based on the shape and size of segmented region. The performance of the proposed technique is tested and validated by using UBIRIS, MMU and CASIA iris image database.
format Conference or Workshop Item
author Mat Ibrahim, Masrullizam
Awang Md Isa, Azmi
Darsono, Abd Majid
author_facet Mat Ibrahim, Masrullizam
Awang Md Isa, Azmi
Darsono, Abd Majid
author_sort Mat Ibrahim, Masrullizam
title Eye closure and open detection using Adaptive Thresholding Histogram Enhancement (ATHE) technique and connected components utilisation
title_short Eye closure and open detection using Adaptive Thresholding Histogram Enhancement (ATHE) technique and connected components utilisation
title_full Eye closure and open detection using Adaptive Thresholding Histogram Enhancement (ATHE) technique and connected components utilisation
title_fullStr Eye closure and open detection using Adaptive Thresholding Histogram Enhancement (ATHE) technique and connected components utilisation
title_full_unstemmed Eye closure and open detection using Adaptive Thresholding Histogram Enhancement (ATHE) technique and connected components utilisation
title_sort eye closure and open detection using adaptive thresholding histogram enhancement (athe) technique and connected components utilisation
publishDate 2014
url http://eprints.utem.edu.my/id/eprint/14024/1/Eye_Closure_and_Open_Detection_Using_Adaptive_Thresholding_Histogram_Enhancement_%28ATHE%29.pdf
http://eprints.utem.edu.my/id/eprint/14024/
_version_ 1768012346000670720
score 13.160551