Development of building heat detection system: an improvement study
The increment of the numbers for accidents due to building safety system errors has created a serious disaster over the year. Due to that reason, this paper presents the entitled Building Heat Detection System (BHD System)by the objectives to develop the proper circuit in order to secure the detecti...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Ijecse
2014
|
Subjects: | |
Online Access: | http://eprints.utem.edu.my/id/eprint/12307/1/2014_Development_of_Building_Heat_Detection_System_An_Improvement_Study.pdf http://eprints.utem.edu.my/id/eprint/12307/ http://www.ijaeee.com/research-paper-publication-volume.php |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utem.eprints.12307 |
---|---|
record_format |
eprints |
spelling |
my.utem.eprints.123072023-07-18T15:08:15Z http://eprints.utem.edu.my/id/eprint/12307/ Development of building heat detection system: an improvement study Sulaima, Mohamad Fani Foo, Jia En Wan Daud, Wan Mohd Bukhari Jali, Mohd Hafiz Ahmad Izzuddin, Tarmizi TK Electrical engineering. Electronics Nuclear engineering The increment of the numbers for accidents due to building safety system errors has created a serious disaster over the year. Due to that reason, this paper presents the entitled Building Heat Detection System (BHD System)by the objectives to develop the proper circuit in order to secure the detection device during the building fire attack. A BHD system, also known as fire protection system consists of heat sensing and monitoring system. The sensors detect extreme heat in an area or zone; the control unit processes the signals and sets off evacuation alarms to alert building occupants. This study focused on the design and fabrication of the system prototype to demonstrate the operation of a BHD system in case of fire accidents. Hose reel indicator is included to display the exact location in a building to aid in firefighting. On top of that, exit indicators were added to show the available exits should fire breaks out in a building. This study is hoped to help the system engineers to improve and secure their building safety system in the future. Ijecse 2014-04-28 Article PeerReviewed text en http://eprints.utem.edu.my/id/eprint/12307/1/2014_Development_of_Building_Heat_Detection_System_An_Improvement_Study.pdf Sulaima, Mohamad Fani and Foo, Jia En and Wan Daud, Wan Mohd Bukhari and Jali, Mohd Hafiz and Ahmad Izzuddin, Tarmizi (2014) Development of building heat detection system: an improvement study. International Journal of Advances in Electrical and Electronics Engineering, 3 (1). pp. 75-81. ISSN 2319-1112 http://www.ijaeee.com/research-paper-publication-volume.php |
institution |
Universiti Teknikal Malaysia Melaka |
building |
UTEM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknikal Malaysia Melaka |
content_source |
UTEM Institutional Repository |
url_provider |
http://eprints.utem.edu.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Sulaima, Mohamad Fani Foo, Jia En Wan Daud, Wan Mohd Bukhari Jali, Mohd Hafiz Ahmad Izzuddin, Tarmizi Development of building heat detection system: an improvement study |
description |
The increment of the numbers for accidents due to building safety system errors has created a serious disaster over the year. Due to that reason, this paper presents the entitled Building Heat Detection System (BHD System)by the objectives to develop the proper circuit in order to secure the detection device during the building fire attack. A BHD system, also known as fire protection system consists of heat sensing and monitoring system. The sensors detect extreme heat in an area or zone; the control unit processes the signals and sets off evacuation alarms to alert building occupants. This study focused on the design and fabrication of the system prototype to demonstrate the operation of a BHD system in case of fire accidents. Hose reel indicator is included to display the exact location in a building to aid in firefighting. On top of that, exit indicators were added to show the available exits should fire breaks out in a building. This study is hoped to help the system engineers to improve and secure their building safety system in the future. |
format |
Article |
author |
Sulaima, Mohamad Fani Foo, Jia En Wan Daud, Wan Mohd Bukhari Jali, Mohd Hafiz Ahmad Izzuddin, Tarmizi |
author_facet |
Sulaima, Mohamad Fani Foo, Jia En Wan Daud, Wan Mohd Bukhari Jali, Mohd Hafiz Ahmad Izzuddin, Tarmizi |
author_sort |
Sulaima, Mohamad Fani |
title |
Development of building heat detection system: an improvement study |
title_short |
Development of building heat detection system: an improvement study |
title_full |
Development of building heat detection system: an improvement study |
title_fullStr |
Development of building heat detection system: an improvement study |
title_full_unstemmed |
Development of building heat detection system: an improvement study |
title_sort |
development of building heat detection system: an improvement study |
publisher |
Ijecse |
publishDate |
2014 |
url |
http://eprints.utem.edu.my/id/eprint/12307/1/2014_Development_of_Building_Heat_Detection_System_An_Improvement_Study.pdf http://eprints.utem.edu.my/id/eprint/12307/ http://www.ijaeee.com/research-paper-publication-volume.php |
_version_ |
1772815993627738112 |
score |
13.214268 |