Simulation Single Phase Active Filter Based on p-q technique using MATLAB/Simulink Development Tools Environment
This paper presents a single phase shunt active power filter based on instantaneous power theory. The active filter will be connected directly to utility in order to reduce THD of load current, in this case the utility is TNB.The instantaneous power theory also known as p-q theory is used for thre...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2011
|
Subjects: | |
Online Access: | http://eprints.utem.edu.my/id/eprint/11840/1/Simulation_Single_Phase_Shunt_Active_Filter_Based.pdf http://eprints.utem.edu.my/id/eprint/11840/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | This paper presents a single phase shunt active
power filter based on instantaneous power theory. The
active filter will be connected directly to utility in order to reduce THD of load current, in this case the utility is TNB.The instantaneous power theory also known as p-q theory is used for three phase active filter and this paper proves that the p-q theory can also be implemented for single phase active filter. Since the system has only single phase signal for both voltage and current, thus the dummy signal with 120º different angels must be generated for input of the p-q theory. The p-q technique will generate six signals PWM for switching IGBT, but only two of the signals will be used to control the switching IGBT. The simulation results are on MATLAB/Simulink environment tools presented in order to demonstrate the performance of the current load on single phase shunt active power filter. |
---|