Analysis of lightning-caused ferroresonance in Capacitor Voltage Transformer (CVT)

Power networks contain capacitances and inductances that can saturate, presenting opportunities for ferroresonance to occur. Most power equipment is designed through linear theory but ferromagnetic materials are highly non-linear and when they resonate, the non-linearity produces currents and voltag...

Full description

Saved in:
Bibliographic Details
Main Authors: Abdul Halim, Abu Bakar, Ahmad Nasarudin, Abd Rahim, Mohd Zambri, Mohd Khairi
Format: Article
Language:English
Published: Elsevier 2011
Subjects:
Online Access:http://eprints.utem.edu.my/id/eprint/11249/1/Elsevier.pdf
http://eprints.utem.edu.my/id/eprint/11249/
http://www.sciencedirect.com/science/article/pii/S014206151100113X#
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utem.eprints.11249
record_format eprints
spelling my.utem.eprints.112492015-05-28T04:16:24Z http://eprints.utem.edu.my/id/eprint/11249/ Analysis of lightning-caused ferroresonance in Capacitor Voltage Transformer (CVT) Abdul Halim, Abu Bakar Ahmad Nasarudin, Abd Rahim Mohd Zambri, Mohd Khairi TK Electrical engineering. Electronics Nuclear engineering Power networks contain capacitances and inductances that can saturate, presenting opportunities for ferroresonance to occur. Most power equipment is designed through linear theory but ferromagnetic materials are highly non-linear and when they resonate, the non-linearity produces currents and voltages that are larger than usual. Ferroresonance is a complex, non-linear electrical phenomenon. It can cause dielectric and thermal problems through overvoltage, an intrinsic phenomenon present in all networks. A network dynamic response to lightning and switching will be energy storage and release. The transfer of energy will propagate an overvoltage through the network and damage substation equipment when lightning strikes near the substation. Application of conventional mathematics is inappropriate to ferroresonance study in which actual events are simulated. Lightning strikes that occurred near a substation and that led to explosion of CVTs have been reported, so this study investigates the effect of a lightning strike on a tower with a 132 kV Capacitor Voltage Transformer (CVT). Alternative Transient Program (ATP) was used for the simulation which duplicated the lightning-strike effect that causes a CVT to explode. Elsevier 2011-11 Article PeerReviewed application/pdf en http://eprints.utem.edu.my/id/eprint/11249/1/Elsevier.pdf Abdul Halim, Abu Bakar and Ahmad Nasarudin, Abd Rahim and Mohd Zambri, Mohd Khairi (2011) Analysis of lightning-caused ferroresonance in Capacitor Voltage Transformer (CVT). International Journal of Electrical Power & Energy Systems, Volume (Issue ). pp. 1536-1541. ISSN 0142-0615 http://www.sciencedirect.com/science/article/pii/S014206151100113X#
institution Universiti Teknikal Malaysia Melaka
building UTEM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknikal Malaysia Melaka
content_source UTEM Institutional Repository
url_provider http://eprints.utem.edu.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Abdul Halim, Abu Bakar
Ahmad Nasarudin, Abd Rahim
Mohd Zambri, Mohd Khairi
Analysis of lightning-caused ferroresonance in Capacitor Voltage Transformer (CVT)
description Power networks contain capacitances and inductances that can saturate, presenting opportunities for ferroresonance to occur. Most power equipment is designed through linear theory but ferromagnetic materials are highly non-linear and when they resonate, the non-linearity produces currents and voltages that are larger than usual. Ferroresonance is a complex, non-linear electrical phenomenon. It can cause dielectric and thermal problems through overvoltage, an intrinsic phenomenon present in all networks. A network dynamic response to lightning and switching will be energy storage and release. The transfer of energy will propagate an overvoltage through the network and damage substation equipment when lightning strikes near the substation. Application of conventional mathematics is inappropriate to ferroresonance study in which actual events are simulated. Lightning strikes that occurred near a substation and that led to explosion of CVTs have been reported, so this study investigates the effect of a lightning strike on a tower with a 132 kV Capacitor Voltage Transformer (CVT). Alternative Transient Program (ATP) was used for the simulation which duplicated the lightning-strike effect that causes a CVT to explode.
format Article
author Abdul Halim, Abu Bakar
Ahmad Nasarudin, Abd Rahim
Mohd Zambri, Mohd Khairi
author_facet Abdul Halim, Abu Bakar
Ahmad Nasarudin, Abd Rahim
Mohd Zambri, Mohd Khairi
author_sort Abdul Halim, Abu Bakar
title Analysis of lightning-caused ferroresonance in Capacitor Voltage Transformer (CVT)
title_short Analysis of lightning-caused ferroresonance in Capacitor Voltage Transformer (CVT)
title_full Analysis of lightning-caused ferroresonance in Capacitor Voltage Transformer (CVT)
title_fullStr Analysis of lightning-caused ferroresonance in Capacitor Voltage Transformer (CVT)
title_full_unstemmed Analysis of lightning-caused ferroresonance in Capacitor Voltage Transformer (CVT)
title_sort analysis of lightning-caused ferroresonance in capacitor voltage transformer (cvt)