Evaluation of the image quality by using MEGP and HEGP collimators for Iodine-131 in planar imaging

Purpose: High-energy general-purpose (HEGP) collimators are mostly used for iodine- 131 in SPECT and planar imaging, while medium-energy general-purpose (MEGP) collimators are seldom used due to the high radiation of iodine-131. In this study, we evaluated the image quality by using MEGP and HEGP...

Full description

Saved in:
Bibliographic Details
Main Author: Jianan, Ding
Format: Thesis
Language:English
Published: 2024
Subjects:
Online Access:http://eprints.usm.my/61331/1/Ding%20Jianan-E.pdf
http://eprints.usm.my/61331/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.usm.eprints.61331
record_format eprints
spelling my.usm.eprints.61331 http://eprints.usm.my/61331/ Evaluation of the image quality by using MEGP and HEGP collimators for Iodine-131 in planar imaging Jianan, Ding R Medicine RA440-440.87 Study and teaching. Research RC71-78.7 Examination. Diagnosis Including raiography Purpose: High-energy general-purpose (HEGP) collimators are mostly used for iodine- 131 in SPECT and planar imaging, while medium-energy general-purpose (MEGP) collimators are seldom used due to the high radiation of iodine-131. In this study, we evaluated the image quality by using MEGP and HEGP collimators with different activities of iodine-131 in planar imaging. Aspects of image quality evaluated include sensitivity, contrast, signal-to-noise ratio, and resolution. Materials and methods: To scan the iodine-131 in several activities, three petri dishes were used to contain iodine-131. Each petri dish contained 0.2 mCi, 0.4 mCi, and 0.6 mCi of iodine-131, and saline was also added to the petri dish. The planar technique produces static images of petri dishes with iodine-131 from two detectors, and then the information about the petri dishes and background were measured in Xeleris workstation. Based on the specific formulas, sensitivity, contrast, SNR, and resolution were calculated. Results: Sensitivity in the MEGP collimator is higher than that in the HEGP collimator, while SNR for the HEGP collimator is higher than that in the MEGP collimator. As for resolution and contrast, the MEGP and HEGP collimators show almost similar but still slightly different results in the generated images. Conclusion: All in all, MEGP and HEGP collimators have their own strengths in image quality using low-activity of iodine-131. Sensitivity in the MEGP collimator is better, and SNR in the HEGP collimator is better. 2024-06 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/61331/1/Ding%20Jianan-E.pdf Jianan, Ding (2024) Evaluation of the image quality by using MEGP and HEGP collimators for Iodine-131 in planar imaging. Other thesis, Universiti Sains Malaysia.
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic R Medicine
RA440-440.87 Study and teaching. Research
RC71-78.7 Examination. Diagnosis Including raiography
spellingShingle R Medicine
RA440-440.87 Study and teaching. Research
RC71-78.7 Examination. Diagnosis Including raiography
Jianan, Ding
Evaluation of the image quality by using MEGP and HEGP collimators for Iodine-131 in planar imaging
description Purpose: High-energy general-purpose (HEGP) collimators are mostly used for iodine- 131 in SPECT and planar imaging, while medium-energy general-purpose (MEGP) collimators are seldom used due to the high radiation of iodine-131. In this study, we evaluated the image quality by using MEGP and HEGP collimators with different activities of iodine-131 in planar imaging. Aspects of image quality evaluated include sensitivity, contrast, signal-to-noise ratio, and resolution. Materials and methods: To scan the iodine-131 in several activities, three petri dishes were used to contain iodine-131. Each petri dish contained 0.2 mCi, 0.4 mCi, and 0.6 mCi of iodine-131, and saline was also added to the petri dish. The planar technique produces static images of petri dishes with iodine-131 from two detectors, and then the information about the petri dishes and background were measured in Xeleris workstation. Based on the specific formulas, sensitivity, contrast, SNR, and resolution were calculated. Results: Sensitivity in the MEGP collimator is higher than that in the HEGP collimator, while SNR for the HEGP collimator is higher than that in the MEGP collimator. As for resolution and contrast, the MEGP and HEGP collimators show almost similar but still slightly different results in the generated images. Conclusion: All in all, MEGP and HEGP collimators have their own strengths in image quality using low-activity of iodine-131. Sensitivity in the MEGP collimator is better, and SNR in the HEGP collimator is better.
format Thesis
author Jianan, Ding
author_facet Jianan, Ding
author_sort Jianan, Ding
title Evaluation of the image quality by using MEGP and HEGP collimators for Iodine-131 in planar imaging
title_short Evaluation of the image quality by using MEGP and HEGP collimators for Iodine-131 in planar imaging
title_full Evaluation of the image quality by using MEGP and HEGP collimators for Iodine-131 in planar imaging
title_fullStr Evaluation of the image quality by using MEGP and HEGP collimators for Iodine-131 in planar imaging
title_full_unstemmed Evaluation of the image quality by using MEGP and HEGP collimators for Iodine-131 in planar imaging
title_sort evaluation of the image quality by using megp and hegp collimators for iodine-131 in planar imaging
publishDate 2024
url http://eprints.usm.my/61331/1/Ding%20Jianan-E.pdf
http://eprints.usm.my/61331/
_version_ 1816131400373370880
score 13.214268