Comparative study of image quality between gold nanoparticles and iodine contrast media using mobile and general X-Ray

To comparatively investigate the effects of Iodinated contrast media (CM) and Gold nanoparticles as potential contrast media to increase the image quality in general radiography. AuNps and Iodine were prepared in 3mMol, 5mMol, 10mMol, 15mMol, 20mMol, 30mMol and 40mMol. Those samples were exposed...

Full description

Saved in:
Bibliographic Details
Main Author: Said, Nooriedayu Mohd
Format: Monograph
Language:English
Published: Universiti Sains Malaysia 2016
Subjects:
Online Access:http://eprints.usm.my/61240/1/NOORIEDAYU%20BINTI%20MOHD%20SAID%20-%20e.pdf
http://eprints.usm.my/61240/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.usm.eprints.61240
record_format eprints
spelling my.usm.eprints.61240 http://eprints.usm.my/61240/ Comparative study of image quality between gold nanoparticles and iodine contrast media using mobile and general X-Ray Said, Nooriedayu Mohd Q Science RC71-78.7 Examination. Diagnosis Including raiography To comparatively investigate the effects of Iodinated contrast media (CM) and Gold nanoparticles as potential contrast media to increase the image quality in general radiography. AuNps and Iodine were prepared in 3mMol, 5mMol, 10mMol, 15mMol, 20mMol, 30mMol and 40mMol. Those samples were exposed under digital radiography (DR) and computed radiography (CR) techniques from 50 kVp to 110kVp and 5 mAs. The regions of interests (ROIs) were drawn on the image to obtain the mean pixel value (MPV). Signal-to-Noise Ratio (SNR), Contrast-to-Noise Ratio (CNR) and Mean Pixel Contrast (MPC) then were calculated from MPV. The SNR value of AuNPs and Iodine contrast media were dependent on the tube potential used. The SNR value increase linearly with tube potential for CR and for DR the linear increase stop at 70 kVp and remain constant. The CNR value also show similar pattern for AuNPs and iodine but show significant different at higher kVps. The MPC also found to be higher in DR compared to CR. The study found that 40 mMol produce the best image quality for CR and 3 mMol is enough to obtain similar results with DR. This study indicates the potential of AuNPs as contrast agent. However, more optimization on the nanoparticles concentration and characteristic as well as the tube potential is necessary to translate the application of AuNPs into clinical practice. Universiti Sains Malaysia 2016 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/61240/1/NOORIEDAYU%20BINTI%20MOHD%20SAID%20-%20e.pdf Said, Nooriedayu Mohd (2016) Comparative study of image quality between gold nanoparticles and iodine contrast media using mobile and general X-Ray. Project Report. Universiti Sains Malaysia. (Submitted)
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic Q Science
RC71-78.7 Examination. Diagnosis Including raiography
spellingShingle Q Science
RC71-78.7 Examination. Diagnosis Including raiography
Said, Nooriedayu Mohd
Comparative study of image quality between gold nanoparticles and iodine contrast media using mobile and general X-Ray
description To comparatively investigate the effects of Iodinated contrast media (CM) and Gold nanoparticles as potential contrast media to increase the image quality in general radiography. AuNps and Iodine were prepared in 3mMol, 5mMol, 10mMol, 15mMol, 20mMol, 30mMol and 40mMol. Those samples were exposed under digital radiography (DR) and computed radiography (CR) techniques from 50 kVp to 110kVp and 5 mAs. The regions of interests (ROIs) were drawn on the image to obtain the mean pixel value (MPV). Signal-to-Noise Ratio (SNR), Contrast-to-Noise Ratio (CNR) and Mean Pixel Contrast (MPC) then were calculated from MPV. The SNR value of AuNPs and Iodine contrast media were dependent on the tube potential used. The SNR value increase linearly with tube potential for CR and for DR the linear increase stop at 70 kVp and remain constant. The CNR value also show similar pattern for AuNPs and iodine but show significant different at higher kVps. The MPC also found to be higher in DR compared to CR. The study found that 40 mMol produce the best image quality for CR and 3 mMol is enough to obtain similar results with DR. This study indicates the potential of AuNPs as contrast agent. However, more optimization on the nanoparticles concentration and characteristic as well as the tube potential is necessary to translate the application of AuNPs into clinical practice.
format Monograph
author Said, Nooriedayu Mohd
author_facet Said, Nooriedayu Mohd
author_sort Said, Nooriedayu Mohd
title Comparative study of image quality between gold nanoparticles and iodine contrast media using mobile and general X-Ray
title_short Comparative study of image quality between gold nanoparticles and iodine contrast media using mobile and general X-Ray
title_full Comparative study of image quality between gold nanoparticles and iodine contrast media using mobile and general X-Ray
title_fullStr Comparative study of image quality between gold nanoparticles and iodine contrast media using mobile and general X-Ray
title_full_unstemmed Comparative study of image quality between gold nanoparticles and iodine contrast media using mobile and general X-Ray
title_sort comparative study of image quality between gold nanoparticles and iodine contrast media using mobile and general x-ray
publisher Universiti Sains Malaysia
publishDate 2016
url http://eprints.usm.my/61240/1/NOORIEDAYU%20BINTI%20MOHD%20SAID%20-%20e.pdf
http://eprints.usm.my/61240/
_version_ 1816131398838255616
score 13.214268