Indoor air quality and sick building syndrome among staffs in Universiti Sains Malaysia Health Campus, Kubang kerian, Kelantan

A comparative cross sectional study was conducted to determine the association between Indoor Air Quality (IAQ) and Sick Building Syndrome (SBS) in USM Health Campus. A total ninety office workers were selected where 45 workers were from Registration Management Complex Building (New building). A s...

Full description

Saved in:
Bibliographic Details
Main Author: Jun, Kok Ern
Format: Monograph
Language:English
Published: Universiti Sains Malaysia 2016
Subjects:
Online Access:http://eprints.usm.my/61236/1/KOK%20ERN%20JUN%20-%20e.pdf
http://eprints.usm.my/61236/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.usm.eprints.61236
record_format eprints
spelling my.usm.eprints.61236 http://eprints.usm.my/61236/ Indoor air quality and sick building syndrome among staffs in Universiti Sains Malaysia Health Campus, Kubang kerian, Kelantan Jun, Kok Ern RA0421 Public health. Hygiene. Preventive Medicine A comparative cross sectional study was conducted to determine the association between Indoor Air Quality (IAQ) and Sick Building Syndrome (SBS) in USM Health Campus. A total ninety office workers were selected where 45 workers were from Registration Management Complex Building (New building). A set of questionnaire adopted from Industry Code of Practice (1COP) 2010 was used to assess the prevalence of SBS. Meanwhile, IAQ parameters were monitored by using the Handheld 3016 IAQ Particle Counter and Multi Function Ventilation Meter. All IAQ parameters were below the limit standard set by DOSH and USEPA except air velocity in old building which is lower than the acceptable range standard set by DOSH. The level of IAQ parameter for PMio and total particulate matter (TPM) in old building was significantly higher compared to new building (Z= -2.495, p = 0.013) & ( Z = -2.873, p = 0.014). SBS prevalence was 51.1 % for new building while 64.4% for old building, however, the difference was not significant (p 0.05). Besides, there was a significant different of drowsiness among respondents between old and new building As a conclusion, the level of all IAQ for both buildings in USM Health Campus was below the limit standard except air velocity in old building which lower than the acceptable range standard set by DOSH while the prevalence of SBS among staffs was found to be high in both building. Therefore, regular maintenance of ventilation and control measures to ensure a good IAQ should be maintained. Further study is recommended to determine risk factors to prevent high prevalence of SBS. Universiti Sains Malaysia 2016 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/61236/1/KOK%20ERN%20JUN%20-%20e.pdf Jun, Kok Ern (2016) Indoor air quality and sick building syndrome among staffs in Universiti Sains Malaysia Health Campus, Kubang kerian, Kelantan. Project Report. Universiti Sains Malaysia. (Submitted)
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic RA0421 Public health. Hygiene. Preventive Medicine
spellingShingle RA0421 Public health. Hygiene. Preventive Medicine
Jun, Kok Ern
Indoor air quality and sick building syndrome among staffs in Universiti Sains Malaysia Health Campus, Kubang kerian, Kelantan
description A comparative cross sectional study was conducted to determine the association between Indoor Air Quality (IAQ) and Sick Building Syndrome (SBS) in USM Health Campus. A total ninety office workers were selected where 45 workers were from Registration Management Complex Building (New building). A set of questionnaire adopted from Industry Code of Practice (1COP) 2010 was used to assess the prevalence of SBS. Meanwhile, IAQ parameters were monitored by using the Handheld 3016 IAQ Particle Counter and Multi Function Ventilation Meter. All IAQ parameters were below the limit standard set by DOSH and USEPA except air velocity in old building which is lower than the acceptable range standard set by DOSH. The level of IAQ parameter for PMio and total particulate matter (TPM) in old building was significantly higher compared to new building (Z= -2.495, p = 0.013) & ( Z = -2.873, p = 0.014). SBS prevalence was 51.1 % for new building while 64.4% for old building, however, the difference was not significant (p 0.05). Besides, there was a significant different of drowsiness among respondents between old and new building As a conclusion, the level of all IAQ for both buildings in USM Health Campus was below the limit standard except air velocity in old building which lower than the acceptable range standard set by DOSH while the prevalence of SBS among staffs was found to be high in both building. Therefore, regular maintenance of ventilation and control measures to ensure a good IAQ should be maintained. Further study is recommended to determine risk factors to prevent high prevalence of SBS.
format Monograph
author Jun, Kok Ern
author_facet Jun, Kok Ern
author_sort Jun, Kok Ern
title Indoor air quality and sick building syndrome among staffs in Universiti Sains Malaysia Health Campus, Kubang kerian, Kelantan
title_short Indoor air quality and sick building syndrome among staffs in Universiti Sains Malaysia Health Campus, Kubang kerian, Kelantan
title_full Indoor air quality and sick building syndrome among staffs in Universiti Sains Malaysia Health Campus, Kubang kerian, Kelantan
title_fullStr Indoor air quality and sick building syndrome among staffs in Universiti Sains Malaysia Health Campus, Kubang kerian, Kelantan
title_full_unstemmed Indoor air quality and sick building syndrome among staffs in Universiti Sains Malaysia Health Campus, Kubang kerian, Kelantan
title_sort indoor air quality and sick building syndrome among staffs in universiti sains malaysia health campus, kubang kerian, kelantan
publisher Universiti Sains Malaysia
publishDate 2016
url http://eprints.usm.my/61236/1/KOK%20ERN%20JUN%20-%20e.pdf
http://eprints.usm.my/61236/
_version_ 1817842961458659328
score 13.222552