Development Of An Automatic Calculation Method For Ct Dose Estimation Based On Individual Specific Size In Paediatric Population

The current dose estimation based on CTDIvol in paediatric CT leads to significant inaccuracies in dose estimation due to inadequate size consideration. Size-specific dose estimate (SSDE) was employed to correct the effect resulting from the use of current CT protocols and minimise the radiation dos...

Full description

Saved in:
Bibliographic Details
Main Author: Abdulkadir, Muhammad Kabir
Format: Thesis
Language:English
Published: 2022
Subjects:
Online Access:http://eprints.usm.my/59760/1/MUHAMMAD%20KABIR%20ABDULKADIR%20-%20TESIS24.pdf
http://eprints.usm.my/59760/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.usm.eprints.59760
record_format eprints
spelling my.usm.eprints.59760 http://eprints.usm.my/59760/ Development Of An Automatic Calculation Method For Ct Dose Estimation Based On Individual Specific Size In Paediatric Population Abdulkadir, Muhammad Kabir R5-920 Medicine (General) The current dose estimation based on CTDIvol in paediatric CT leads to significant inaccuracies in dose estimation due to inadequate size consideration. Size-specific dose estimate (SSDE) was employed to correct the effect resulting from the use of current CT protocols and minimise the radiation dose that been delivered more than double the intended dose to paediatric. This study aims to evaluate the current paediatric CT protocols and associated dose received by paediatric from CT scans. This study also aims to develop an automatic calculator using MATLAB algorithm for accurate patient size measurement and SSDE calculation. A retrospective survey was conducted to investigate CT protocols and associated dose (CTDIvol), patient size (manual measured Deff and Dw) and SSDE of paediatric patients undergoing head and abdomen CT scans. An automated calculation algorithm was developed on MATLAB platform for patient size measurement (Deff) and SSDE calculation. Numerical data analysed were scan parameters, estimated doses (CTDIvol and SSDE), manual and automated Deff estimates of patient size. Scan parameters and dose (CTDIvol) were compared with diagnostic reference ranges (DRLs) while automated SSDE calculator was validated with the manual size measurement and SSDE calculation. Local diagnostic reference ranges and patient size distribution were derived. The results showed a disparity of 7 to 51% between CTDIvol and SSDE. Automated calculator yields accurate measured size and calculated SSDE with an estimation error of less than 2%. 2022-05 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/59760/1/MUHAMMAD%20KABIR%20ABDULKADIR%20-%20TESIS24.pdf Abdulkadir, Muhammad Kabir (2022) Development Of An Automatic Calculation Method For Ct Dose Estimation Based On Individual Specific Size In Paediatric Population. PhD thesis, Universiti Sains Malaysia.
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic R5-920 Medicine (General)
spellingShingle R5-920 Medicine (General)
Abdulkadir, Muhammad Kabir
Development Of An Automatic Calculation Method For Ct Dose Estimation Based On Individual Specific Size In Paediatric Population
description The current dose estimation based on CTDIvol in paediatric CT leads to significant inaccuracies in dose estimation due to inadequate size consideration. Size-specific dose estimate (SSDE) was employed to correct the effect resulting from the use of current CT protocols and minimise the radiation dose that been delivered more than double the intended dose to paediatric. This study aims to evaluate the current paediatric CT protocols and associated dose received by paediatric from CT scans. This study also aims to develop an automatic calculator using MATLAB algorithm for accurate patient size measurement and SSDE calculation. A retrospective survey was conducted to investigate CT protocols and associated dose (CTDIvol), patient size (manual measured Deff and Dw) and SSDE of paediatric patients undergoing head and abdomen CT scans. An automated calculation algorithm was developed on MATLAB platform for patient size measurement (Deff) and SSDE calculation. Numerical data analysed were scan parameters, estimated doses (CTDIvol and SSDE), manual and automated Deff estimates of patient size. Scan parameters and dose (CTDIvol) were compared with diagnostic reference ranges (DRLs) while automated SSDE calculator was validated with the manual size measurement and SSDE calculation. Local diagnostic reference ranges and patient size distribution were derived. The results showed a disparity of 7 to 51% between CTDIvol and SSDE. Automated calculator yields accurate measured size and calculated SSDE with an estimation error of less than 2%.
format Thesis
author Abdulkadir, Muhammad Kabir
author_facet Abdulkadir, Muhammad Kabir
author_sort Abdulkadir, Muhammad Kabir
title Development Of An Automatic Calculation Method For Ct Dose Estimation Based On Individual Specific Size In Paediatric Population
title_short Development Of An Automatic Calculation Method For Ct Dose Estimation Based On Individual Specific Size In Paediatric Population
title_full Development Of An Automatic Calculation Method For Ct Dose Estimation Based On Individual Specific Size In Paediatric Population
title_fullStr Development Of An Automatic Calculation Method For Ct Dose Estimation Based On Individual Specific Size In Paediatric Population
title_full_unstemmed Development Of An Automatic Calculation Method For Ct Dose Estimation Based On Individual Specific Size In Paediatric Population
title_sort development of an automatic calculation method for ct dose estimation based on individual specific size in paediatric population
publishDate 2022
url http://eprints.usm.my/59760/1/MUHAMMAD%20KABIR%20ABDULKADIR%20-%20TESIS24.pdf
http://eprints.usm.my/59760/
_version_ 1789425566374428672
score 13.211869