Estimation of exposure rate to nuclear medicine personnel during cardiac spect imaging using direct and indirect methods: a phantom study

This study was to determine the exposure rate to personnel during the 99mTc cardiac SPECT imaging procedure using direct and indirect methods. In this study, the single head gamma camera model Symbia-E manufactured by Siemens and the dual head gamma camera model Philips Adac Forte were used to sca...

Full description

Saved in:
Bibliographic Details
Main Author: Mubin, Zuraida Ab
Format: Monograph
Language:English
Published: Universiti Sains Malaysia 2015
Subjects:
Online Access:http://eprints.usm.my/58314/1/ZURAIDA%20BINTI%20AB%20MUBIN%20-%20e.pdf
http://eprints.usm.my/58314/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.usm.eprints.58314
record_format eprints
spelling my.usm.eprints.58314 http://eprints.usm.my/58314/ Estimation of exposure rate to nuclear medicine personnel during cardiac spect imaging using direct and indirect methods: a phantom study Mubin, Zuraida Ab RC71-78.7 Examination. Diagnosis Including raiography This study was to determine the exposure rate to personnel during the 99mTc cardiac SPECT imaging procedure using direct and indirect methods. In this study, the single head gamma camera model Symbia-E manufactured by Siemens and the dual head gamma camera model Philips Adac Forte were used to scan the cardiac phantom. The direct method was conducted by measuring the exposure rate from radioactive cardiac phantom using Victoreen 451P-RYR survey meter at various distances (0.5 m, 1.0 m, 1.5 m and 2.0 m). The indirect method was based on mathematical model of exposure rate. The results indicated that exposure rates from direct method were higher than indirect method for both single and dual head gamma camera. The percentage differences between direct and indirect method for 23.71 mCi 99mTc for single head cardiac SPECT imaging at various distances were between 57.35% and 75%. For 21.80 mCi 99mTc, the percentage differences were between 29.20% 19.70% and 50%. On the other hand, The percentage differences between direct and indirect method for 23.71 mCi 99mTc for dual head cardiac SPECT imaging were between 41.20% and 50%. For 21.80 mCi 99mTc, the percentage differences were between 16.70% and 48.70% and for 19.89 mCi 99mTc, the percentage differences were between 20% and 52.10%. As conclusion, the calculated exposure from indirect method for both single and dual head cardiac SPECT imaging were lower than the actual exposure obtained from a direct method. Measurement of the exposure rates received from the cardiac phantom is important to ensure minimal hazard to personnel in nuclear medicine department and to propose a safe working protocol for personnel performing cardiac SPECT imaging. Universiti Sains Malaysia 2015 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/58314/1/ZURAIDA%20BINTI%20AB%20MUBIN%20-%20e.pdf Mubin, Zuraida Ab (2015) Estimation of exposure rate to nuclear medicine personnel during cardiac spect imaging using direct and indirect methods: a phantom study. Project Report. Universiti Sains Malaysia. (Submitted)
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic RC71-78.7 Examination. Diagnosis Including raiography
spellingShingle RC71-78.7 Examination. Diagnosis Including raiography
Mubin, Zuraida Ab
Estimation of exposure rate to nuclear medicine personnel during cardiac spect imaging using direct and indirect methods: a phantom study
description This study was to determine the exposure rate to personnel during the 99mTc cardiac SPECT imaging procedure using direct and indirect methods. In this study, the single head gamma camera model Symbia-E manufactured by Siemens and the dual head gamma camera model Philips Adac Forte were used to scan the cardiac phantom. The direct method was conducted by measuring the exposure rate from radioactive cardiac phantom using Victoreen 451P-RYR survey meter at various distances (0.5 m, 1.0 m, 1.5 m and 2.0 m). The indirect method was based on mathematical model of exposure rate. The results indicated that exposure rates from direct method were higher than indirect method for both single and dual head gamma camera. The percentage differences between direct and indirect method for 23.71 mCi 99mTc for single head cardiac SPECT imaging at various distances were between 57.35% and 75%. For 21.80 mCi 99mTc, the percentage differences were between 29.20% 19.70% and 50%. On the other hand, The percentage differences between direct and indirect method for 23.71 mCi 99mTc for dual head cardiac SPECT imaging were between 41.20% and 50%. For 21.80 mCi 99mTc, the percentage differences were between 16.70% and 48.70% and for 19.89 mCi 99mTc, the percentage differences were between 20% and 52.10%. As conclusion, the calculated exposure from indirect method for both single and dual head cardiac SPECT imaging were lower than the actual exposure obtained from a direct method. Measurement of the exposure rates received from the cardiac phantom is important to ensure minimal hazard to personnel in nuclear medicine department and to propose a safe working protocol for personnel performing cardiac SPECT imaging.
format Monograph
author Mubin, Zuraida Ab
author_facet Mubin, Zuraida Ab
author_sort Mubin, Zuraida Ab
title Estimation of exposure rate to nuclear medicine personnel during cardiac spect imaging using direct and indirect methods: a phantom study
title_short Estimation of exposure rate to nuclear medicine personnel during cardiac spect imaging using direct and indirect methods: a phantom study
title_full Estimation of exposure rate to nuclear medicine personnel during cardiac spect imaging using direct and indirect methods: a phantom study
title_fullStr Estimation of exposure rate to nuclear medicine personnel during cardiac spect imaging using direct and indirect methods: a phantom study
title_full_unstemmed Estimation of exposure rate to nuclear medicine personnel during cardiac spect imaging using direct and indirect methods: a phantom study
title_sort estimation of exposure rate to nuclear medicine personnel during cardiac spect imaging using direct and indirect methods: a phantom study
publisher Universiti Sains Malaysia
publishDate 2015
url http://eprints.usm.my/58314/1/ZURAIDA%20BINTI%20AB%20MUBIN%20-%20e.pdf
http://eprints.usm.my/58314/
_version_ 1768007873257799680
score 13.211869