The Impact Of Uplift Forces On The Connection Of Steel Cladding For Rural Houses In Malaysia

The research of the impact of wind uplift forces and pressures on the steel cladding and the fastener behaviour for the rural houses is the focus of the study. Based on a recent survey done on the damaged roofing system in the rural houses due to heavy windstorm affected many locations in Malaysi...

Full description

Saved in:
Bibliographic Details
Main Author: Akramah, Hamzah Atef
Format: Monograph
Language:English
Published: Universiti Sains Malaysia 2021
Subjects:
Online Access:http://eprints.usm.my/57381/1/The%20Impact%20Of%20Uplift%20Forces%20On%20The%20Connection%20Of%20Steel%20Cladding%20For%20Rural%20Houses%20In%20Malaysia.pdf
http://eprints.usm.my/57381/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.usm.eprints.57381
record_format eprints
spelling my.usm.eprints.57381 http://eprints.usm.my/57381/ The Impact Of Uplift Forces On The Connection Of Steel Cladding For Rural Houses In Malaysia Akramah, Hamzah Atef T Technology TA1-2040 Engineering (General). Civil engineering (General) The research of the impact of wind uplift forces and pressures on the steel cladding and the fastener behaviour for the rural houses is the focus of the study. Based on a recent survey done on the damaged roofing system in the rural houses due to heavy windstorm affected many locations in Malaysia, showed that steel roof cladding sheets was the most affected part of the building. The rural areas in Malaysia have a huge number of non-engineered houses where the roof made out from the affordable material especially the steel roof cladding such as trapezoidal and corrugated. The connection between the purlin cladding used a fastener namely a nail or screw. Most of previous studies on this field were focusing on the low rise engineered building, which followed the engineering building codes, while this study only focused on the houses built with no or limited engineering guidance. The research adopted the numerical study method using ANSYS workbench software, via the static structure subsection to simulate the steel roof cladding and the fasteners. The finite element models subjected to several values of uplift forces, which are 5, 6, and 7kN for trapezoidal steel cladding, whereas, due to the curvy shapes of the corrugated steel cladding where the uplift forces were replaced by the uplift pressures which are 3.8, 4.6, and 5.3kPa. The study suggested adding a strip with different widths, 75mm, 100mm and 150mm near the central fastener, where the most critical stress usually occurred and highest deflection recorded. The results show a sufficient improvement regarding the deformation of the steel cladding and the fastener reaction force. The use of additional strip method has reduced the effect of wind uplift forces by 27% - 82% and the pull through capacity increases by 22% - 54% for the fastener. The additional strip presence showed a large impact which will lead to protect the steel roof cladding connection from failure where it is the most critical part of the roofing system. Universiti Sains Malaysia 2021-06-01 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/57381/1/The%20Impact%20Of%20Uplift%20Forces%20On%20The%20Connection%20Of%20Steel%20Cladding%20For%20Rural%20Houses%20In%20Malaysia.pdf Akramah, Hamzah Atef (2021) The Impact Of Uplift Forces On The Connection Of Steel Cladding For Rural Houses In Malaysia. Project Report. Universiti Sains Malaysia, Pusat Pengajian Kejuruteraan Awam. (Submitted)
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic T Technology
TA1-2040 Engineering (General). Civil engineering (General)
spellingShingle T Technology
TA1-2040 Engineering (General). Civil engineering (General)
Akramah, Hamzah Atef
The Impact Of Uplift Forces On The Connection Of Steel Cladding For Rural Houses In Malaysia
description The research of the impact of wind uplift forces and pressures on the steel cladding and the fastener behaviour for the rural houses is the focus of the study. Based on a recent survey done on the damaged roofing system in the rural houses due to heavy windstorm affected many locations in Malaysia, showed that steel roof cladding sheets was the most affected part of the building. The rural areas in Malaysia have a huge number of non-engineered houses where the roof made out from the affordable material especially the steel roof cladding such as trapezoidal and corrugated. The connection between the purlin cladding used a fastener namely a nail or screw. Most of previous studies on this field were focusing on the low rise engineered building, which followed the engineering building codes, while this study only focused on the houses built with no or limited engineering guidance. The research adopted the numerical study method using ANSYS workbench software, via the static structure subsection to simulate the steel roof cladding and the fasteners. The finite element models subjected to several values of uplift forces, which are 5, 6, and 7kN for trapezoidal steel cladding, whereas, due to the curvy shapes of the corrugated steel cladding where the uplift forces were replaced by the uplift pressures which are 3.8, 4.6, and 5.3kPa. The study suggested adding a strip with different widths, 75mm, 100mm and 150mm near the central fastener, where the most critical stress usually occurred and highest deflection recorded. The results show a sufficient improvement regarding the deformation of the steel cladding and the fastener reaction force. The use of additional strip method has reduced the effect of wind uplift forces by 27% - 82% and the pull through capacity increases by 22% - 54% for the fastener. The additional strip presence showed a large impact which will lead to protect the steel roof cladding connection from failure where it is the most critical part of the roofing system.
format Monograph
author Akramah, Hamzah Atef
author_facet Akramah, Hamzah Atef
author_sort Akramah, Hamzah Atef
title The Impact Of Uplift Forces On The Connection Of Steel Cladding For Rural Houses In Malaysia
title_short The Impact Of Uplift Forces On The Connection Of Steel Cladding For Rural Houses In Malaysia
title_full The Impact Of Uplift Forces On The Connection Of Steel Cladding For Rural Houses In Malaysia
title_fullStr The Impact Of Uplift Forces On The Connection Of Steel Cladding For Rural Houses In Malaysia
title_full_unstemmed The Impact Of Uplift Forces On The Connection Of Steel Cladding For Rural Houses In Malaysia
title_sort impact of uplift forces on the connection of steel cladding for rural houses in malaysia
publisher Universiti Sains Malaysia
publishDate 2021
url http://eprints.usm.my/57381/1/The%20Impact%20Of%20Uplift%20Forces%20On%20The%20Connection%20Of%20Steel%20Cladding%20For%20Rural%20Houses%20In%20Malaysia.pdf
http://eprints.usm.my/57381/
_version_ 1761617392227581952
score 13.211869