Relative validity of three Bioelectrical Impedance Analysis equipments in measuring body composition of adults

The aim of this study is to determine relative validity of bioelectrical impedance analysis (BIA) equipments for the measurement of body composition among adults. Three different Tanita BIA equipments namely SC 330, SC 240 and BC 545 were used to detennine body composition of participants with SC...

Full description

Saved in:
Bibliographic Details
Main Author: Ghazali, Fatin Huwaina Mohd
Format: Monograph
Language:English
Published: Pusat Pengajian Sains Kesihatan, Universiti Sains Malaysia 2013
Subjects:
Online Access:http://eprints.usm.my/57378/1/FATIN%20HUWAINA%20BINTI%20MOHD%20GHAZALI-24%20pages.pdf
http://eprints.usm.my/57378/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.usm.eprints.57378
record_format eprints
spelling my.usm.eprints.57378 http://eprints.usm.my/57378/ Relative validity of three Bioelectrical Impedance Analysis equipments in measuring body composition of adults Ghazali, Fatin Huwaina Mohd QH301 Biology The aim of this study is to determine relative validity of bioelectrical impedance analysis (BIA) equipments for the measurement of body composition among adults. Three different Tanita BIA equipments namely SC 330, SC 240 and BC 545 were used to detennine body composition of participants with SC330 as the reference method. A total of 120 subjects (74 girls and 46 boys) aged 19-30 years from Universiti Sains Malaysia (USM) Kelantan took part in this study. From the study, both SC 240 and BC 545 showed significant correlation with SC 330 for body fat percentage. Specifically, in male the highest correlation \vith SC 330 for body fat percentage was SC 240 (r= 0.97, p <0.001). Meanwhile, the highest correlation ·with SC 330 for body fat percentage in female was BC 545 (r= 0.97, p <0.001). Mean body fat percentage tor SC 330 was 22.85% (SD 6.08). The mean percent body fat for SC 240 was 22.85% (SD 8.59) showed no significant difference from SC330. There was significant difference of mean body fat percentage by BC 545 to SC 330 which is 24.32% (SD 8.97). In conclusion, SC 240 shown to have good correlation \vith SC 330 and can be used as a reliable equipment in measuring body composition among adults. Pusat Pengajian Sains Kesihatan, Universiti Sains Malaysia 2013-06 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/57378/1/FATIN%20HUWAINA%20BINTI%20MOHD%20GHAZALI-24%20pages.pdf Ghazali, Fatin Huwaina Mohd (2013) Relative validity of three Bioelectrical Impedance Analysis equipments in measuring body composition of adults. Other. Pusat Pengajian Sains Kesihatan, Universiti Sains Malaysia. (Submitted)
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic QH301 Biology
spellingShingle QH301 Biology
Ghazali, Fatin Huwaina Mohd
Relative validity of three Bioelectrical Impedance Analysis equipments in measuring body composition of adults
description The aim of this study is to determine relative validity of bioelectrical impedance analysis (BIA) equipments for the measurement of body composition among adults. Three different Tanita BIA equipments namely SC 330, SC 240 and BC 545 were used to detennine body composition of participants with SC330 as the reference method. A total of 120 subjects (74 girls and 46 boys) aged 19-30 years from Universiti Sains Malaysia (USM) Kelantan took part in this study. From the study, both SC 240 and BC 545 showed significant correlation with SC 330 for body fat percentage. Specifically, in male the highest correlation \vith SC 330 for body fat percentage was SC 240 (r= 0.97, p <0.001). Meanwhile, the highest correlation ·with SC 330 for body fat percentage in female was BC 545 (r= 0.97, p <0.001). Mean body fat percentage tor SC 330 was 22.85% (SD 6.08). The mean percent body fat for SC 240 was 22.85% (SD 8.59) showed no significant difference from SC330. There was significant difference of mean body fat percentage by BC 545 to SC 330 which is 24.32% (SD 8.97). In conclusion, SC 240 shown to have good correlation \vith SC 330 and can be used as a reliable equipment in measuring body composition among adults.
format Monograph
author Ghazali, Fatin Huwaina Mohd
author_facet Ghazali, Fatin Huwaina Mohd
author_sort Ghazali, Fatin Huwaina Mohd
title Relative validity of three Bioelectrical Impedance Analysis equipments in measuring body composition of adults
title_short Relative validity of three Bioelectrical Impedance Analysis equipments in measuring body composition of adults
title_full Relative validity of three Bioelectrical Impedance Analysis equipments in measuring body composition of adults
title_fullStr Relative validity of three Bioelectrical Impedance Analysis equipments in measuring body composition of adults
title_full_unstemmed Relative validity of three Bioelectrical Impedance Analysis equipments in measuring body composition of adults
title_sort relative validity of three bioelectrical impedance analysis equipments in measuring body composition of adults
publisher Pusat Pengajian Sains Kesihatan, Universiti Sains Malaysia
publishDate 2013
url http://eprints.usm.my/57378/1/FATIN%20HUWAINA%20BINTI%20MOHD%20GHAZALI-24%20pages.pdf
http://eprints.usm.my/57378/
_version_ 1761617391836463104
score 13.159267