Development Of A System For Measuring Pedal Force In Arm Leg Pedal Exercise

Nowadays, stroke issues become important field which many researchers and scientist have work on how to get the best method for their recovery. For stroke patients, the most popular method to recover is through aerobic exercise like walking, cycling, or running. Rehabilitation cycle have been used i...

Full description

Saved in:
Bibliographic Details
Main Author: Najib, Mohammad Amirul Akmal Mohd
Format: Monograph
Language:English
Published: Universiti Sains Malaysia 2021
Subjects:
Online Access:http://eprints.usm.my/55881/1/Development%20Of%20A%20System%20For%20Measuring%20Pedal%20Force%20In%20Arm%20Leg%20Pedal%20Exercise.pdf
http://eprints.usm.my/55881/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.usm.eprints.55881
record_format eprints
spelling my.usm.eprints.55881 http://eprints.usm.my/55881/ Development Of A System For Measuring Pedal Force In Arm Leg Pedal Exercise Najib, Mohammad Amirul Akmal Mohd T Technology TJ1 Mechanical engineering and machinery Nowadays, stroke issues become important field which many researchers and scientist have work on how to get the best method for their recovery. For stroke patients, the most popular method to recover is through aerobic exercise like walking, cycling, or running. Rehabilitation cycle have been used in medication field for the hemiparesis patients. Current designs do not provide no feedback system to the patient. It is difficult to determine whether the patient perform effectively. The problem that occurs during the therapy is time consuming because only single limbs were treated at one time. The purpose of this study is to determine the parameters for both active and passive mode and the effectiveness of feedback system to the stroke patients during the therapy. At the end experiment the active and passive activity for both upper and lower limb in term of angular speed, angular acceleration, speed and acceleration have been study. From the result it can be shown that the average of angular speed, angular acceleration, speed and acceleration, the lowest are active disengage at upper limb with -0.18482 deg/s, active engage at lower limb with -0.37149 deg/s2 and passive engage activity at upper limb which is 0.127865 m/s and -8.2759E-05 m/s2 respectively. To see the significant of active and passive activities, the T-test with 95% confidence interval was conducted. The results are only speed for both limbs have significant difference while others have no significant value. From this study, it can be clearly observed that active and passive activity almost have same effect. So, the severe stroke patients can do the passive mode exercise with have almost same effect as active mode before they can move their own limbs. The feedback system to detect the force difference that too large have been shown in the result part. The figure show that when the force difference is too large which the fraction of difference and total force value exceed 0.4 or -0.4, the LED will start to be blinking until the force difference become stable. The T-test with 95% confidence interval was conducted between both legs at active and passive mode. It shows that there were significant different for both active and passive mode. So, the feedback system can notify the user if force difference is too big where they will be improving force between both legs. Universiti Sains Malaysia 2021-07-01 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/55881/1/Development%20Of%20A%20System%20For%20Measuring%20Pedal%20Force%20In%20Arm%20Leg%20Pedal%20Exercise.pdf Najib, Mohammad Amirul Akmal Mohd (2021) Development Of A System For Measuring Pedal Force In Arm Leg Pedal Exercise. Project Report. Universiti Sains Malaysia, Pusat Pengajian Kejuruteraan Mekanik. (Submitted)
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic T Technology
TJ1 Mechanical engineering and machinery
spellingShingle T Technology
TJ1 Mechanical engineering and machinery
Najib, Mohammad Amirul Akmal Mohd
Development Of A System For Measuring Pedal Force In Arm Leg Pedal Exercise
description Nowadays, stroke issues become important field which many researchers and scientist have work on how to get the best method for their recovery. For stroke patients, the most popular method to recover is through aerobic exercise like walking, cycling, or running. Rehabilitation cycle have been used in medication field for the hemiparesis patients. Current designs do not provide no feedback system to the patient. It is difficult to determine whether the patient perform effectively. The problem that occurs during the therapy is time consuming because only single limbs were treated at one time. The purpose of this study is to determine the parameters for both active and passive mode and the effectiveness of feedback system to the stroke patients during the therapy. At the end experiment the active and passive activity for both upper and lower limb in term of angular speed, angular acceleration, speed and acceleration have been study. From the result it can be shown that the average of angular speed, angular acceleration, speed and acceleration, the lowest are active disengage at upper limb with -0.18482 deg/s, active engage at lower limb with -0.37149 deg/s2 and passive engage activity at upper limb which is 0.127865 m/s and -8.2759E-05 m/s2 respectively. To see the significant of active and passive activities, the T-test with 95% confidence interval was conducted. The results are only speed for both limbs have significant difference while others have no significant value. From this study, it can be clearly observed that active and passive activity almost have same effect. So, the severe stroke patients can do the passive mode exercise with have almost same effect as active mode before they can move their own limbs. The feedback system to detect the force difference that too large have been shown in the result part. The figure show that when the force difference is too large which the fraction of difference and total force value exceed 0.4 or -0.4, the LED will start to be blinking until the force difference become stable. The T-test with 95% confidence interval was conducted between both legs at active and passive mode. It shows that there were significant different for both active and passive mode. So, the feedback system can notify the user if force difference is too big where they will be improving force between both legs.
format Monograph
author Najib, Mohammad Amirul Akmal Mohd
author_facet Najib, Mohammad Amirul Akmal Mohd
author_sort Najib, Mohammad Amirul Akmal Mohd
title Development Of A System For Measuring Pedal Force In Arm Leg Pedal Exercise
title_short Development Of A System For Measuring Pedal Force In Arm Leg Pedal Exercise
title_full Development Of A System For Measuring Pedal Force In Arm Leg Pedal Exercise
title_fullStr Development Of A System For Measuring Pedal Force In Arm Leg Pedal Exercise
title_full_unstemmed Development Of A System For Measuring Pedal Force In Arm Leg Pedal Exercise
title_sort development of a system for measuring pedal force in arm leg pedal exercise
publisher Universiti Sains Malaysia
publishDate 2021
url http://eprints.usm.my/55881/1/Development%20Of%20A%20System%20For%20Measuring%20Pedal%20Force%20In%20Arm%20Leg%20Pedal%20Exercise.pdf
http://eprints.usm.my/55881/
_version_ 1751537288690532352
score 13.211869