Gasoline Quality Monitoring Via Vehicle OBD Data Analysis
Research octane number (RON) determines the quality of knocking resistance of a fuel in a spark ignition (SI) engine. In Malaysia, the most commonly found petrol fuel types are RON95 and RON97. One of the objectives of this research project is to compare the engine performance of the vehicle by st...
Saved in:
Main Author: | |
---|---|
Format: | Monograph |
Language: | English |
Published: |
Universiti Sains Malaysia
2018
|
Subjects: | |
Online Access: | http://eprints.usm.my/54297/1/Gasoline%20Quality%20Monitoring%20Via%20Vehicle%20OBD%20Data%20Analysis_Nurul%20Aqilah%20Ismail_M4.pdf http://eprints.usm.my/54297/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.usm.eprints.54297 |
---|---|
record_format |
eprints |
spelling |
my.usm.eprints.54297 http://eprints.usm.my/54297/ Gasoline Quality Monitoring Via Vehicle OBD Data Analysis Ismail, Nurul Aqilah T Technology TJ Mechanical engineering and machinery Research octane number (RON) determines the quality of knocking resistance of a fuel in a spark ignition (SI) engine. In Malaysia, the most commonly found petrol fuel types are RON95 and RON97. One of the objectives of this research project is to compare the engine performance of the vehicle by studying the spark ignition of the engine when it is fuelled with gasoline fuel of different octane number and from the different petrol station. The comparative analysis spark advance timing with research octane number (RON) 95, and 97 was carried out on a Perodua Myvi SE 2017 under different types of gasoline fuels available in the Parit Buntar town. The different gasoline fuels consist of Caltex, Petron, Petronas and Shell. The results showed a special pattern for each fuel RON; these patterns were obtained using the spark advance timing, throttle/ load applied to the vehicle and the speed the vehicle is driven. The results are then further proved with SHATOX SX-200 portable octane tester to read the actual RON reading of the sample of the gasoline fuels. Different petrol stations alter their fuel differently. This explains the different reading obtained as the gasoline fuels are tested with the portable octane tester. Universiti Sains Malaysia 2018-05-01 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/54297/1/Gasoline%20Quality%20Monitoring%20Via%20Vehicle%20OBD%20Data%20Analysis_Nurul%20Aqilah%20Ismail_M4.pdf Ismail, Nurul Aqilah (2018) Gasoline Quality Monitoring Via Vehicle OBD Data Analysis. Project Report. Universiti Sains Malaysia, Pusat Pengajian Kejuruteraan Mekanikal. (Submitted) |
institution |
Universiti Sains Malaysia |
building |
Hamzah Sendut Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Sains Malaysia |
content_source |
USM Institutional Repository |
url_provider |
http://eprints.usm.my/ |
language |
English |
topic |
T Technology TJ Mechanical engineering and machinery |
spellingShingle |
T Technology TJ Mechanical engineering and machinery Ismail, Nurul Aqilah Gasoline Quality Monitoring Via Vehicle OBD Data Analysis |
description |
Research octane number (RON) determines the quality of knocking resistance of a fuel in a spark ignition (SI) engine. In Malaysia, the most commonly found petrol fuel types
are RON95 and RON97. One of the objectives of this research project is to compare the engine performance of the vehicle by studying the spark ignition of the engine when it is
fuelled with gasoline fuel of different octane number and from the different petrol station. The comparative analysis spark advance timing with research octane number (RON) 95,
and 97 was carried out on a Perodua Myvi SE 2017 under different types of gasoline fuels available in the Parit Buntar town. The different gasoline fuels consist of Caltex,
Petron, Petronas and Shell. The results showed a special pattern for each fuel RON; these patterns were obtained using the spark advance timing, throttle/ load applied to the
vehicle and the speed the vehicle is driven. The results are then further proved with SHATOX SX-200 portable octane tester to read the actual RON reading of the sample of the gasoline fuels. Different petrol stations alter their fuel differently. This explains the different reading obtained as the gasoline fuels are tested with the portable octane tester. |
format |
Monograph |
author |
Ismail, Nurul Aqilah |
author_facet |
Ismail, Nurul Aqilah |
author_sort |
Ismail, Nurul Aqilah |
title |
Gasoline Quality Monitoring Via Vehicle OBD Data Analysis |
title_short |
Gasoline Quality Monitoring Via Vehicle OBD Data Analysis |
title_full |
Gasoline Quality Monitoring Via Vehicle OBD Data Analysis |
title_fullStr |
Gasoline Quality Monitoring Via Vehicle OBD Data Analysis |
title_full_unstemmed |
Gasoline Quality Monitoring Via Vehicle OBD Data Analysis |
title_sort |
gasoline quality monitoring via vehicle obd data analysis |
publisher |
Universiti Sains Malaysia |
publishDate |
2018 |
url |
http://eprints.usm.my/54297/1/Gasoline%20Quality%20Monitoring%20Via%20Vehicle%20OBD%20Data%20Analysis_Nurul%20Aqilah%20Ismail_M4.pdf http://eprints.usm.my/54297/ |
_version_ |
1743107811275964416 |
score |
13.160551 |