62"d Annual Conference, Cardiological Society of India Kolkata, India 2- 5 Disember 2010

Assessment of reliability of blood pressure measurements among assessors in a clinical trial Wan Nor Arifin1, Wan Arfah Nadiah Wan Abdul Jamil', Muhammad Irfan Abdul JalaP, Nani Draman4, Nyi Nyi Naing5 '·'.l.SUnit of Biostatistics and Research Methodology, School of Medical Science...

Full description

Saved in:
Bibliographic Details
Main Author: Wan Nor Arifin, Wan Mansor
Format: Monograph
Language:English
Published: Pusat Pengajian Sains Perubatan 2010
Subjects:
Online Access:http://eprints.usm.my/54204/1/DR%20WAN%20NOR%20ARIFIN%20WAN%20MANSOR%20-%20e.pdf
http://eprints.usm.my/54204/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.usm.eprints.54204
record_format eprints
spelling my.usm.eprints.54204 http://eprints.usm.my/54204/ 62"d Annual Conference, Cardiological Society of India Kolkata, India 2- 5 Disember 2010 Wan Nor Arifin, Wan Mansor P Language and Literature R Medicine (General) Assessment of reliability of blood pressure measurements among assessors in a clinical trial Wan Nor Arifin1, Wan Arfah Nadiah Wan Abdul Jamil', Muhammad Irfan Abdul JalaP, Nani Draman4, Nyi Nyi Naing5 '·'.l.SUnit of Biostatistics and Research Methodology, School of Medical Sciences, Universiti Sains Malaysia, 16150 Kubang Kerian, Kelantan, Malaysia 'Department of Family Medicine, School ofMedical Sciences, Universiti Sains Malaysia, 16150 Kubang, Kerian, Kelantan, Malaysia Iqtroduction: To ensure the reliability of blood pressure (BP) readings in a clinical trial, sources of errors due to measurement must be reduced as much as possible. Apart from following standard procedures for BP measurement and ensuring good equipments, the measurement errors that arise from the assessors themselves should be assessed. Objective: To assess reliability of BP readings among assessors involved in a clinical trial requiring BP measurement using intraclass correlation (ICC). Methodology: A reliability study on blood pressure readings of 5 assessors was conducted. 11 volunteers were recruited for the study. Precalculated sample size was 1 0.3, and the number of participants in this study exceeded the required sample size. BP was measured using regularly maintained mercury sphygmanometers. Recommendations by Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure (JNC 7) for BP measurement in office setting were followed. The outcomes were systolic and diastolic BP readings . •. · Intraclass correlation (ICC) two-way random model, absolute agreement type, was chosen for the analysis of the systolic and diastolic BP readings to assess the reliability of the assessors. Results: The inter-rater reliability for systolic and diastolic BP measurements as expressed by ICC (single measure) were 0.87 (95% confidence interval [CI] 0.722, 0.956) and 0.77 (95% CI 0.560, 0.918) respectively. Conclusion: The reliability for systolic BP measurements was very good (in range of 0.81 - 1.0) with ICC (single measure) of 0.87, while the reliability for diastolic measurements was considered good (in range of 0.61 - 0.8) with ICC (single measure) of 0.77. We concluded that assessors were reliable in their assessment of BP on his/her own, as indicated by the ICC using single measure results. Pusat Pengajian Sains Perubatan 2010 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/54204/1/DR%20WAN%20NOR%20ARIFIN%20WAN%20MANSOR%20-%20e.pdf Wan Nor Arifin, Wan Mansor (2010) 62"d Annual Conference, Cardiological Society of India Kolkata, India 2- 5 Disember 2010. Other. Pusat Pengajian Sains Perubatan. (Submitted)
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic P Language and Literature
R Medicine (General)
spellingShingle P Language and Literature
R Medicine (General)
Wan Nor Arifin, Wan Mansor
62"d Annual Conference, Cardiological Society of India Kolkata, India 2- 5 Disember 2010
description Assessment of reliability of blood pressure measurements among assessors in a clinical trial Wan Nor Arifin1, Wan Arfah Nadiah Wan Abdul Jamil', Muhammad Irfan Abdul JalaP, Nani Draman4, Nyi Nyi Naing5 '·'.l.SUnit of Biostatistics and Research Methodology, School of Medical Sciences, Universiti Sains Malaysia, 16150 Kubang Kerian, Kelantan, Malaysia 'Department of Family Medicine, School ofMedical Sciences, Universiti Sains Malaysia, 16150 Kubang, Kerian, Kelantan, Malaysia Iqtroduction: To ensure the reliability of blood pressure (BP) readings in a clinical trial, sources of errors due to measurement must be reduced as much as possible. Apart from following standard procedures for BP measurement and ensuring good equipments, the measurement errors that arise from the assessors themselves should be assessed. Objective: To assess reliability of BP readings among assessors involved in a clinical trial requiring BP measurement using intraclass correlation (ICC). Methodology: A reliability study on blood pressure readings of 5 assessors was conducted. 11 volunteers were recruited for the study. Precalculated sample size was 1 0.3, and the number of participants in this study exceeded the required sample size. BP was measured using regularly maintained mercury sphygmanometers. Recommendations by Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure (JNC 7) for BP measurement in office setting were followed. The outcomes were systolic and diastolic BP readings . •. · Intraclass correlation (ICC) two-way random model, absolute agreement type, was chosen for the analysis of the systolic and diastolic BP readings to assess the reliability of the assessors. Results: The inter-rater reliability for systolic and diastolic BP measurements as expressed by ICC (single measure) were 0.87 (95% confidence interval [CI] 0.722, 0.956) and 0.77 (95% CI 0.560, 0.918) respectively. Conclusion: The reliability for systolic BP measurements was very good (in range of 0.81 - 1.0) with ICC (single measure) of 0.87, while the reliability for diastolic measurements was considered good (in range of 0.61 - 0.8) with ICC (single measure) of 0.77. We concluded that assessors were reliable in their assessment of BP on his/her own, as indicated by the ICC using single measure results.
format Monograph
author Wan Nor Arifin, Wan Mansor
author_facet Wan Nor Arifin, Wan Mansor
author_sort Wan Nor Arifin, Wan Mansor
title 62"d Annual Conference, Cardiological Society of India Kolkata, India 2- 5 Disember 2010
title_short 62"d Annual Conference, Cardiological Society of India Kolkata, India 2- 5 Disember 2010
title_full 62"d Annual Conference, Cardiological Society of India Kolkata, India 2- 5 Disember 2010
title_fullStr 62"d Annual Conference, Cardiological Society of India Kolkata, India 2- 5 Disember 2010
title_full_unstemmed 62"d Annual Conference, Cardiological Society of India Kolkata, India 2- 5 Disember 2010
title_sort 62"d annual conference, cardiological society of india kolkata, india 2- 5 disember 2010
publisher Pusat Pengajian Sains Perubatan
publishDate 2010
url http://eprints.usm.my/54204/1/DR%20WAN%20NOR%20ARIFIN%20WAN%20MANSOR%20-%20e.pdf
http://eprints.usm.my/54204/
_version_ 1743107798871310336