Heat Transfer Perfomance Of A Synthetic Jet Generated By Diffuser-Shaped Orifice

Synthetic jet impingement cooling has been Identified to be an advanced cooling technique in a variety of applications such as turbine blade cooling, paper drying, and electronic cooling. The high heat removal capabilities with a simple construction of the device, demonstrate the advantage of synth...

Full description

Saved in:
Bibliographic Details
Main Author: Ismail, Mohd Azmi
Format: Monograph
Language:English
Published: Universiti Sains Malaysia 2019
Subjects:
Online Access:http://eprints.usm.my/52813/1/Heat%20Transfer%20Perfomance%20Of%20A%20Synthetic%20Jet%20Generated%20By%20Diffuser-Shaped%20Orifice.pdf
http://eprints.usm.my/52813/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.usm.eprints.52813
record_format eprints
spelling my.usm.eprints.52813 http://eprints.usm.my/52813/ Heat Transfer Perfomance Of A Synthetic Jet Generated By Diffuser-Shaped Orifice Ismail, Mohd Azmi T Technology TJ Mechanical engineering and machinery Synthetic jet impingement cooling has been Identified to be an advanced cooling technique in a variety of applications such as turbine blade cooling, paper drying, and electronic cooling. The high heat removal capabilities with a simple construction of the device, demonstrate the advantage of synthetic jet compared to other methods. In the present work, the 3D numerical simulation using computational fluid dynamics(CFD) is carried out to predict the heat transfer performance of synthetic jet produced by speaker actuator with the diffuser-shape orifice. Numerical predictions are made for an orifice diameter of 6 mm with several opening angles. The excitation frequency of the speaker diaphragm Is fixed at 100 Hz. Three vibration amplitude are used to investigate the effect of the different velocity of synthetic jet. The results showed that the opening angle of 90" is better than 45" and the heat transfer enhancement using a diffuser shaped orifice Is more significant at a higher vibration amplitude. Also, the increment of vibration amplitude more than 0.6mm may not increase the cooling performance of synthetic jet. Universiti Sains Malaysia 2019 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/52813/1/Heat%20Transfer%20Perfomance%20Of%20A%20Synthetic%20Jet%20Generated%20By%20Diffuser-Shaped%20Orifice.pdf Ismail, Mohd Azmi (2019) Heat Transfer Perfomance Of A Synthetic Jet Generated By Diffuser-Shaped Orifice. Project Report. Universiti Sains Malaysia, Pusat Pengajian Kejuruteraan Mekanik. (Submitted)
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic T Technology
TJ Mechanical engineering and machinery
spellingShingle T Technology
TJ Mechanical engineering and machinery
Ismail, Mohd Azmi
Heat Transfer Perfomance Of A Synthetic Jet Generated By Diffuser-Shaped Orifice
description Synthetic jet impingement cooling has been Identified to be an advanced cooling technique in a variety of applications such as turbine blade cooling, paper drying, and electronic cooling. The high heat removal capabilities with a simple construction of the device, demonstrate the advantage of synthetic jet compared to other methods. In the present work, the 3D numerical simulation using computational fluid dynamics(CFD) is carried out to predict the heat transfer performance of synthetic jet produced by speaker actuator with the diffuser-shape orifice. Numerical predictions are made for an orifice diameter of 6 mm with several opening angles. The excitation frequency of the speaker diaphragm Is fixed at 100 Hz. Three vibration amplitude are used to investigate the effect of the different velocity of synthetic jet. The results showed that the opening angle of 90" is better than 45" and the heat transfer enhancement using a diffuser shaped orifice Is more significant at a higher vibration amplitude. Also, the increment of vibration amplitude more than 0.6mm may not increase the cooling performance of synthetic jet.
format Monograph
author Ismail, Mohd Azmi
author_facet Ismail, Mohd Azmi
author_sort Ismail, Mohd Azmi
title Heat Transfer Perfomance Of A Synthetic Jet Generated By Diffuser-Shaped Orifice
title_short Heat Transfer Perfomance Of A Synthetic Jet Generated By Diffuser-Shaped Orifice
title_full Heat Transfer Perfomance Of A Synthetic Jet Generated By Diffuser-Shaped Orifice
title_fullStr Heat Transfer Perfomance Of A Synthetic Jet Generated By Diffuser-Shaped Orifice
title_full_unstemmed Heat Transfer Perfomance Of A Synthetic Jet Generated By Diffuser-Shaped Orifice
title_sort heat transfer perfomance of a synthetic jet generated by diffuser-shaped orifice
publisher Universiti Sains Malaysia
publishDate 2019
url http://eprints.usm.my/52813/1/Heat%20Transfer%20Perfomance%20Of%20A%20Synthetic%20Jet%20Generated%20By%20Diffuser-Shaped%20Orifice.pdf
http://eprints.usm.my/52813/
_version_ 1735387509415739392
score 13.211869